Pulse Wave Velocity Measurement in the Carotid Artery Using an LED-LED Array Pulse Oximeter

被引:1
作者
Campbell, Jake D. [1 ]
Holder-Pearson, Lui [1 ]
Pretty, Christopher G. [1 ]
Bones, Phil [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Mech Engn Dept, Christchurch, New Zealand
[2] Univ Canterbury, Elect Engn Dept, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2020年 / 53卷 / 02期
基金
欧盟地平线“2020”;
关键词
Pulse wave velocity; non-invasive; photoplethysmography; LED-LED detection; carotid artery; STIFFNESS;
D O I
10.1016/j.ifacol.2020.12.406
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Pulse wave velocity (PWV) is frequently used as an early indicator of risk of cardiovascular disease. Conventional methods of PWV measurement are invasive and measure the regional PWV, introducing errors from unknown measurement distance to masking local changes in compliance. This paper describes the development and testing of a non-invasive PWV sensor using photoplethysmograph signals. The sensor measures the pulse in the carotid artery with three sensor arrays spaced at 20 mm, 30 mm and 50 mm spacing. Each array of 20 LED-LED sensors are placed at 5 mm to get the largest amplitude pulse across the neck, and to allow for inaccurate sensor placement. LEDs are used as light emitters and the inherent capacitance of reverse biased LEDs measure the reflected light. The foot-foot and phase difference methods were used to calculate the PWV at each measurement distance. The foot-foot method was more reliable than the phase difference at all distances with a PWV of 5.26 ms(-1) in a single-subject trial. The sample rate of 570 Hz was deemed too slow as one sample difference resulted in a PWV change of 1.5 m s(-1). The developed sensor measured the local PWV within the expected physiological range around 6 m s(-1). All future measurements will be measured at 1 kHz and an increased LED output intensity. Copyright (C) 2020 The Authors.
引用
收藏
页码:16031 / 16036
页数:6
相关论文
共 50 条
  • [31] Wearable Pulse Wave Velocity Sensor using Flexible Piezoelectric Film Array
    Katsuura, Takumi
    Izumi, Shintaro
    Yoshimoto, Masahiko
    Kawaguchi, Hiroshi
    Yoshimoto, Shusuke
    Sekitani, Tsuyoshi
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [32] An invasive but simple and accurate method for ascending aorta-femoral artery pulse wave velocity measurement
    Kilic, Harun
    Yelgec, Selcuk
    Salih, Orcan
    Akdemir, Ramazan
    Karakurt, Ozlem
    Cagirci, Goksel
    Yeter, Ekrem
    Acikel, Sadik
    Dogan, Mehmet
    Arslantas, Ugur
    Baha, Resat Mehmet
    BLOOD PRESSURE, 2013, 22 (01) : 45 - 50
  • [33] Measuring Pulse Wave Velocity Using ECG and Photoplethysmography
    An-Bang Liu
    Po-Chun Hsu
    Zong-Li Chen
    Hsien-Tsai Wu
    Journal of Medical Systems, 2011, 35 : 771 - 777
  • [34] Measuring Pulse Wave Velocity Using ECG and Photoplethysmography
    Liu, An-Bang
    Hsu, Po-Chun
    Chen, Zong-Li
    Wu, Hsien-Tsai
    JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (05) : 771 - 777
  • [35] Development of a technique for determination of pulmonary artery pulse wave velocity in horses
    Silva, Goncalo Teixeira de Almeida
    Guest, Bruce B.
    Gomez, Diego E.
    McGregor, Martine
    Viel, Laurent
    O'Sullivan, M. Lynne
    Runciman, John
    Arroyo, Luis G.
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 122 (05) : 1088 - 1094
  • [36] Distance measurements for the assessment of carotid to femoral pulse wave velocity
    Vermeersch, Sebastian J.
    Rietzschel, Ernst R.
    De Buyzere, Marc L.
    Van Bortel, Luc M.
    Gillebert, Thierry C.
    Verdonck, Pascal R.
    Laurent, Stephane
    Segers, Patrick
    Boutouyrie, Pierre
    JOURNAL OF HYPERTENSION, 2009, 27 (12) : 2377 - U2
  • [37] Carotid-Femoral Pulse Wave Velocity Is Not Increased in Obesity
    Desamericq, Gaelle
    Tissot, Claire-Marie
    Akakpo, Servais
    Tropeano, Anne-Isabelle
    Millasseau, Sandrine
    Macquin-Mavier, Isabelle
    AMERICAN JOURNAL OF HYPERTENSION, 2015, 28 (04) : 546 - 551
  • [38] Variation and variability in carotid-femoral pulse wave velocity
    Kallem R.R.
    Meyers K.E.C.
    Sawinski D.L.
    Townsend R.R.
    Artery Research, 2013, 7 (3-4) : 230 - 233
  • [39] Outcome Associations of Carotid-Femoral Pulse Wave Velocity Vary With Different Measurement Methods
    Girerd, Nicolas
    Legedz, Liliana
    Paget, Vinciane
    Rabilloud, Muriel
    Milon, Hugues
    Bricca, Giampiero
    Lantelme, Pierre
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (12) : 1264 - 1270
  • [40] Prediction of Coronary Artery Disease Extent and Severity Using Pulse Wave Velocity
    Chiha, Joseph
    Mitchell, Paul
    Gopinath, Bamini
    Burlutsky, George
    Plant, Adam
    Kovoor, Pramesh
    Thiagalingam, Aravinda
    PLOS ONE, 2016, 11 (12):