Pulse Wave Velocity Measurement in the Carotid Artery Using an LED-LED Array Pulse Oximeter

被引:1
|
作者
Campbell, Jake D. [1 ]
Holder-Pearson, Lui [1 ]
Pretty, Christopher G. [1 ]
Bones, Phil [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Mech Engn Dept, Christchurch, New Zealand
[2] Univ Canterbury, Elect Engn Dept, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2020年 / 53卷 / 02期
基金
欧盟地平线“2020”;
关键词
Pulse wave velocity; non-invasive; photoplethysmography; LED-LED detection; carotid artery; STIFFNESS;
D O I
10.1016/j.ifacol.2020.12.406
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Pulse wave velocity (PWV) is frequently used as an early indicator of risk of cardiovascular disease. Conventional methods of PWV measurement are invasive and measure the regional PWV, introducing errors from unknown measurement distance to masking local changes in compliance. This paper describes the development and testing of a non-invasive PWV sensor using photoplethysmograph signals. The sensor measures the pulse in the carotid artery with three sensor arrays spaced at 20 mm, 30 mm and 50 mm spacing. Each array of 20 LED-LED sensors are placed at 5 mm to get the largest amplitude pulse across the neck, and to allow for inaccurate sensor placement. LEDs are used as light emitters and the inherent capacitance of reverse biased LEDs measure the reflected light. The foot-foot and phase difference methods were used to calculate the PWV at each measurement distance. The foot-foot method was more reliable than the phase difference at all distances with a PWV of 5.26 ms(-1) in a single-subject trial. The sample rate of 570 Hz was deemed too slow as one sample difference resulted in a PWV change of 1.5 m s(-1). The developed sensor measured the local PWV within the expected physiological range around 6 m s(-1). All future measurements will be measured at 1 kHz and an increased LED output intensity. Copyright (C) 2020 The Authors.
引用
收藏
页码:16031 / 16036
页数:6
相关论文
共 50 条
  • [1] Measurement of local pulse wave velocity for carotid artery by using an ultrasound-based method
    Tang, Chieh-Ju
    Lee, Po-Yang
    Chuang, Yi-Hsiang
    Huang, Chih-Chung
    ULTRASONICS, 2020, 102
  • [2] Measurement of regional pulse-wave velocity using spatial compound imaging of the common carotid artery in vivo
    Nagaoka, Ryo
    Masuno, Genta
    Kobayashi, Kazuto
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    Saijo, Yoshifumi
    ULTRASONICS, 2015, 55 : 92 - 103
  • [3] Pulse wave velocity measurement along the ulnar artery in the wrist region using a high frequency ultrasonic array
    Benchemoul, Maxime
    Mateo, Tony
    Savery, David
    Gehin, Claudine
    Massot, Bertrand
    Ferin, Guillaume
    Vince, Philippe
    Flesch, Martin
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4123 - 4127
  • [4] Aortic pulse wave velocity results depend on which carotid artery is used for the measurements
    Dzeko, Mirela
    Peters, Christian D.
    Kjaergaard, Krista D.
    Jensen, Jens D.
    Jespersen, Bente
    JOURNAL OF HYPERTENSION, 2013, 31 (01) : 117 - 122
  • [5] Pulse Wave Velocity and Flow in the Carotid Artery Versus the Aortic Arch: Effects of Aging
    Kroner, Eleanore S. J.
    Lamb, Hildo J.
    Siebelink, Hans-Marc J.
    Cannegieter, Suzanne C.
    van den Boogaard, Pieter J.
    van der Wall, Ernst E.
    de Roos, Albert
    Westenberg, Jos J. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (02) : 287 - 293
  • [6] Pulse Wave Velocity Measurement in Healthy and Diseased Carotid Arteries In Vivo
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [7] Pulse Wave Velocity Doppler Measurement of Ulnar Artery Using a High-Frequency Probe
    Benchemoul, Maxime
    Savery, David
    Gehin, Claudine
    Massot, Bertrand
    Ferin, Guillaume
    Vince, Philippe
    Flesch, Martin
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [8] Aortic Pulse Wave Velocity and Carotid-Femoral Pulse Wave Velocity: Similarities and Discrepancies
    Piotr Podolec
    Grzegorz Kopeć
    Jakub Podolec
    Piotr Wilkołek
    Marek Krochin
    Paweł Rubiś
    Marcin Cwynar
    Tomasz Grodzicki
    Krzysztof Żmudka
    Wiesława Tracz
    Hypertension Research, 2007, 30 : 1151 - 1158
  • [9] Aortic pulse wave velocity and carotid-femoral pulse wave velocity: Similarities and discrepancies
    Podolec, Piotr
    Kopec, Grzegorz
    Podolec, Jakub
    Wilkolek, Piotr
    Krochin, Marek
    Rubis, Pawel
    Cwynar, Marcin
    Grodzicki, Tomasz
    Zmudka, Krzysztof
    Tracz, Wieslawa
    HYPERTENSION RESEARCH, 2007, 30 (12) : 1151 - 1158
  • [10] COMPARISON OF DIFFERENT PULSE WAVEFORMS FOR LOCAL PULSE WAVE VELOCITY MEASUREMENT IN HEALTHYAND HYPERTENSIVE COMMON CAROTID ARTERIES IN VIVO
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05): : 1111 - 1123