Strain Gauge Analysis of Occlusal Forces on Implant Prostheses at Various Occlusal Heights

被引:8
作者
Cho, Young-Eun [1 ]
Park, Eun-Jin [1 ]
Koak, Jai-Young [2 ,3 ]
Kim, Seong-Kyun [2 ,3 ]
Heo, Seong-Joo [2 ,3 ]
Park, Ji-Man [1 ]
机构
[1] Ewha Womans Univ, Dept Prosthodont, Seoul 158710, South Korea
[2] Seoul Natl Univ, Dept Prosthodont, Seoul, South Korea
[3] Seoul Natl Univ, Dent Res Inst, Seoul, South Korea
关键词
bite force; dental implants; dental stress analysis; pressure transducers; vertical dimension; BITE FORCES; GUIDELINES;
D O I
10.11607/jomi.3040
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate and compare the strain development at different occlusal heights of an implant prosthesis and adjacent teeth through the use of strain gauges. Materials and Methods: A test model was constructed using autopolymerizing polyurethane resin, artificial composite resin teeth, and an implant gold crown in the mandibular first molar area. The resin block containing the implant and the gold crown was sectioned, and two expansion screws were attached perpendicular to the bottom of the resin block on the buccal and lingual sides. The expansion screws were turned to create a gap. Four groups were created based on the occlusal height of the implant gold crown. Three strain gauges were attached to the buccal surfaces of the mandibular right second premolar, implant gold crown, and second molar. Beef jerky, carrot, and bread were used as test foods. A universal testing machine was used to apply compressive forces of 300 N (beef jerky), 250 N (carrot), and 50 N (bread), and the occlusal force was measured in each group. Results: With 300 N, occlusal forces were concentrated on the adjacent teeth when the occlusal height of the implant prosthesis decreased. With 250 and 50 N, when the occlusal height of the implant prosthesis increased, the occlusal force applied to the implant prosthesis increased, but alterations in the implant crown height had little effect on the adjacent teeth. Conclusion: Different amounts of strain in the implant prosthesis and adjacent teeth were recorded depending on the occlusal height of the prosthesis. With 250 or 50 N of force, an increased prosthesis height affected the implant itself. With 300 N of force, decreased occlusal height of the prosthesis resulted in increased force on the adjacent teeth.
引用
收藏
页码:1034 / 1041
页数:8
相关论文
共 31 条
  • [21] Effect of axial loads on implanted-supported partial fixed prostheses by strain gauge analysis
    Oliveira de Vasconcellos, Luis Gustavo
    Nishioka, Renato Sussumu
    Reis de Vasconcellos, Luana Marotta
    Braulino de Melo Nishioka, Lea Nogueira
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2011, 19 (06) : 610 - 615
  • [22] Biomechanical effects of different materials for an occlusal device on implant-supported rehabilitation in a tooth clenching situation. A 3D finite element analysis
    Andrade, Carla Souza
    Costa, Luy de Abreu
    Menechelli, Luana Goncalves
    Lemos, Cleidiel A. A.
    Okamoto, Roberta
    Verri, Fellippo R.
    Batista, Victor Eduardo de Souza
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (07): : 706 - 713
  • [23] A digital image correlation analysis on the influence of crown material in implant-supported prostheses on bone strain distribution
    Tiossi, Rodrigo
    Lin, Lianshan
    Conrad, Heather Joan
    Rodrigues, Renata C. S.
    Heo, Young Cheul
    Chiarello de Mattos, Maria da Gloria
    Fok, Alex Sui-Lun
    Ribeiro, Ricardo Faria
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2012, 56 (01) : 25 - 31
  • [24] Validation of finite element models for strain analysis of implant-supported prostheses using digital image correlation
    Tiossi, Rodrigo
    Vasco, Marco A. A.
    Lin, Lianshan
    Conrad, Heather J.
    Bezzon, Osvaldo L.
    Ribeiro, Ricardo F.
    Fok, Alex S. L.
    [J]. DENTAL MATERIALS, 2013, 29 (07) : 788 - 796
  • [25] Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads
    Kim, Jae-Hoon
    Noh, Gunwoo
    Hong, Seoung-Jin
    Lee, Hyeonjong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (05) : 316 - 321
  • [26] Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis
    Mao, Zhen
    Bleiel, Hannah
    Beuer, Florian
    Boese, Mats Wernfried Heinrich
    Soetebeer, Maren
    [J]. JOURNAL OF DENTISTRY, 2024, 146
  • [27] Biomechanical effect of an occlusal device for patients with an implant-supported fixed dental prosthesis under parafunctional loading: A 3D finite element analysis
    Silva, Lorena S.
    Verri, Fellippo R.
    Lemos, Cleidiel A. A.
    Martins, Christine M.
    Pellizzer, Eduardo P.
    de Souza Batista, Victor E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (02) : 223.e1 - 223.e8
  • [28] Comparison of full-arch mandibular reconstruction with dental implants using completely splinted or segmentally splinted prostheses with two different occlusal schemes: A finite-element analysis
    Abrishamkar, Sarah
    Fathi, Amirhossein
    Ghorbani, Mahsa
    Mosharraf, Ramin
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [29] Comparison of non-linear finite element stress analysis with in vitro strain gauge measurements on a morse taper implant
    Iplikçioglu, H
    Akça, K
    Çehreli, MC
    Sahin, S
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (02) : 258 - 265
  • [30] Strain gauge analysis and fracture resistance of implant-supported PEKK hybrid abutments restored with two crown materials: An in vitro study
    El-Mahdy, Manar
    Aboelfadl, Ahmad
    Ahmed, Fatma
    El-Banna, Ahmed
    Wahsh, Marwa
    [J]. DENTAL AND MEDICAL PROBLEMS, 2023, 60 (03) : 497 - 503