Carbon nanotube-based aptasensor for sensitive electrochemical detection of whole-cell Salmonella

被引:81
作者
Hasan, Md Rakibul [1 ]
Pulingam, Thiruchelvi [1 ]
Appaturi, Jimmy Nelson [1 ]
Zifruddin, Anis Nadyra [2 ]
Teh, Swe Jyan [3 ]
Lim, Teck Wei [2 ]
Ibrahim, Fatimah [5 ]
Leo, Bey Fen [3 ,4 ]
Thong, Kwai Lin [2 ]
机构
[1] Univ Malaya, Inst Grad Studies, Nanotechnol & Catalysis Res Ctr NANOCAT, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Sci, Inst Biol Sci, Kuala Lumpur 50603, Malaysia
[3] Univ Malaya, Fac Engn, Ctr Innovat Med Engn, Kuala Lumpur 50603, Malaysia
[4] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur 50603, Malaysia
[5] Univ Malaya, Fac Med, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
关键词
Aptasensor; Cyclic voltammetry; Electrochemical impedance spectroscopy; Multi-walled carbon nanotubes; Scanning electron microscopy; REDUCED GRAPHENE OXIDE; VIRUS CORE ANTIGEN; BACTERIAL DETECTION; PATHOGEN DETECTION; DNA APTAMERS; BIOSENSORS; NANOCOMPOSITE; TYPHIMURIUM; PLATFORM; GOLD;
D O I
10.1016/j.ab.2018.06.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, an amino-modified aptasensor using multi-walled carbon nanotubes (MWCNTs)-deposited ITO electrode was prepared and evaluated for the detection of pathogenic Salmonella bacteria. An amino-modified aptamer (ssDNA) which binds selectively to whole-cell Salmonella was immobilised on the COOH-rich MWCNTs to produce the ssDNA/MWCNT/ITO electrode. The morphology of the MWCNT before and after interaction with the aptamers were observed using scanning electron microscopy (SEM). Cyclic voltammetry and electrochemical impedance spectroscopy techniques were used to investigate the electrochemical properties and conductivity of the aptasensor. The results showed that the impedance measured at the ssDNA/MWCNT/ITO electrode surface increased after exposure to Salmonella cells, which indicated successful binding of Salmonella on the aptamer-functionalised surface. The developed ssDNA/MWCNT/ITO aptasensor was stable and maintained linearity when the scan rate was increased from 10 mV s(-1) to 90 mV s(-1). The detection limit of the ssDNA/MWCNT/ITO aptasensor, determined from the sensitivity analysis, was found to be 5.5 x 10(1) cfu mL(-1) and 6.7 x 10(1) cfu mL(-1) for S. Enteritidis and S. Typhimurium, respectively. The specificity test demonstrated that Salmonella bound specifically to the ssDNA/MWCNT/ITO aptasensor surface, when compared with non Salmonella spp. The prepared aptasensor was successfully applied for the detection of Salmonella in food samples.
引用
收藏
页码:34 / 43
页数:10
相关论文
共 47 条
[1]   Biosensors for Whole-Cell Bacterial Detection [J].
Ahmed, Asif ;
Rushworth, Jo V. ;
Hirst, Natalie A. ;
Millner, Paul A. .
CLINICAL MICROBIOLOGY REVIEWS, 2014, 27 (03) :631-646
[2]   Nanostructured sensor based on carbon nanotubes and clavanin A for bacterial detection [J].
Andrade, Cesar A. S. ;
Nascimento, Jessica M. ;
Oliveira, Idjane S. ;
de Oliveira, Carlos V. J. ;
de Melo, Celso P. ;
Franco, Octavio L. ;
Oliveira, Maria D. L. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2015, 135 :833-839
[3]  
Chambers JP, 2008, CURR ISSUES MOL BIOL, V10, P1
[4]  
Chen Siyi, 2011, APPL ENV MICROBIOL, V77
[5]   Development of an aptasensor using reduced graphene oxide chitosan complex to detect Salmonella [J].
Dinshaw, Ignatius Julian ;
Muniandy, Shalini ;
Teh, Swe Jyan ;
Ibrahim, Fatimah ;
Leo, Bey Fen ;
Thong, Kwai Lin .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 :88-96
[6]   VIBRATIONAL-MODES OF CARBON NANOTUBES - SPECTROSCOPY AND THEORY [J].
EKLUND, PC ;
HOLDEN, JM ;
JISHI, RA .
CARBON, 1995, 33 (07) :959-972
[7]   A nanohybrid probe based on double recognition of an aptamer MIP grafted onto a MWCNTs-Chit nanocomposite for sensing hepatitis C virus core antigen [J].
Ghanbari, Kazhal ;
Roushani, Mahmoud .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 258 :1066-1071
[8]   Ultra-sensitive aptasensor based on a GQD nanocomposite for detection of hepatitis C virus core antigen [J].
Ghanbari, Kazhal ;
Roushani, Mahmoud ;
Azadbakht, Azadeh .
ANALYTICAL BIOCHEMISTRY, 2017, 534 :64-69
[9]   Impedimetric DNA biosensor based on polyurethane/poly(m-anthranilic acid) nanofibers [J].
Gokce, Zeliha Guler ;
Akalin, Pinar ;
Kok, Fatma Nese ;
Sarac, A. Sezai .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 :719-726
[10]   Recent advances in carbon nanotube based electrochemical biosensors [J].
Gupta, S. ;
Murthy, C. N. ;
Prabha, C. Ratna .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2018, 108 :687-703