REGION BASED 4D TOMOGRAPHIC IMAGE RECONSTRUCTION: APPLICATION TO CARDIAC X-RAY CT

被引:0
作者
Van Eyndhoven, G. [1 ]
Batenburg, K. J. [1 ,2 ]
Sijbers, J. [1 ]
机构
[1] Univ Antwerp, iMinds Vis Lab, B-2610 Antwerp, Belgium
[2] Ctr Wiskunde & Informat, NL-1090 GB Amsterdam, Netherlands
来源
2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP) | 2015年
关键词
cardiac CT; iterative reconstruction; region based SIRT; dynamic CT; 4D CT; dose reduction; MICRO-CT; DYNAMIC CT; ANGIOGRAPHY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray computed tomography (CT) is a powerful tool for non-invasive cardiac imaging. However, radiation dose is a major issue. In this paper, we propose an iterative reconstruction method that reduces the radiation dose without compromising image quality. This is achieved by exploiting prior knowledge in two ways: the reconstructed object is assumed to consist of both stationary and dynamic regions over time and the dynamic region is assumed to have sparse structures after a proper sparsifying space-time transform. Experiments on simulation data and a real mu CT cardiac mouse dataset show that, with comparable image quality, the radiation dose can be substantially reduced compared to conventional acquisition/reconstruction protocols.
引用
收藏
页码:113 / 117
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 2008, Computed tomography: from photonstatistics to modern cone-beam CT
[2]   In vivo small-animal imaging using micro-CT and digital subtraction angiography [J].
Badea, C. T. ;
Drangova, M. ;
Holdsworth, D. W. ;
Johnson, G. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :R319-R350
[3]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[4]   Computational analysis and improvement of SIRT [J].
Gregor, Jens ;
Benson, Thomas .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) :918-924
[5]   Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[6]  
Kak AvinashC., 2001, CLASSICS APPL MATH, V33
[7]   Motion correction for improved target localization with on-board cone-beam computed tomography [J].
Li, T ;
Schreibmann, E ;
Yang, Y ;
Xing, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02) :253-267
[8]   Nonlocal Transform-Domain Filter for Volumetric Data Denoising and Reconstruction [J].
Maggioni, Matteo ;
Katkovnik, Vladimir ;
Egiazarian, Karen ;
Foi, Alessandro .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2013, 22 (01) :119-133
[9]   Cardiac C-arm computed tomography using a 3D+time ROI reconstruction method with spatial and temporal regularization [J].
Mory, Cyril ;
Auvray, Vincent ;
Zhang, Bo ;
Grass, Michael ;
Schaefer, Dirk ;
Chen, S. James ;
Carroll, John D. ;
Rit, Simon ;
Peyrin, Francoise ;
Douek, Philippe ;
Boussel, Loic .
MEDICAL PHYSICS, 2014, 41 (02) :021903
[10]  
Nieman K., 2014, CARDIAC CT, P31