During microfiltration, limiting (J(L)) and critical flux (J(C)) are essential. Using these concepts, the operational zones, have been established for flux (J) versus transmembrane pressure (Delta P-T). However, the resistance model cannot be used for an accurate description of these operational zones. The aim of this work was to evaluate the application of an equation for process parameters determination during skim milk microfiltration. The exponential model, J = J(L)(1 exp(-Delta P-T/(Delta P-T)(C)), allowed a direct determination of J(L) and the critical Delta P-T ((Delta P-T)(C)) and allowed the calculation of J(C) and the limiting Delta P-T ((Delta P-T)(L)). The effect of temperature, concentration factor, and cross-flow velocity over J(L) and (Delta P-T)(C) were evaluated. For J(L) and (Delta P-T)(C), a good fitting was obtained (Radj(2) = 98.12%; R-adj(2) = 97.83%, respectively). These results allow to predict the limiting and critical points for given values of the concentration factor, cross-flow velocity and temperature. Moreover, determination of the operational zones could be established.
引用
收藏
页码:414 / 425
页数:12
相关论文
共 71 条
[51]   Semiempirical modeling of cross-flow microfiltration with periodic reverse filtration [J].
Mallubhotla, H ;
Belfort, G .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (09) :2920-2928
[52]  
Montgomery D., 2001, ANAL EXPT DESIGN, P699
[53]   Flux decline along the flow channel in tubular ultrafiltration modules [J].
Nordin, Anna-Karin ;
Jonsson, Ann-Sofi .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2009, 87 (11A) :1551-1561
[54]   Microfiltration of milk with ceramic membranes [J].
Pafylias, I ;
Cheryan, M ;
Mehaia, MA ;
Saglam, N .
FOOD RESEARCH INTERNATIONAL, 1996, 29 (02) :141-146
[55]   Length dependency of flux and protein permeation in crossflow microfiltration of skimmed milk [J].
Piry, A. ;
Kuhnl, W. ;
Grein, T. ;
Tolkach, A. ;
Ripperger, S. ;
Kulozik, U. .
JOURNAL OF MEMBRANE SCIENCE, 2008, 325 (02) :887-894
[56]   Sub-critical flux fouling in membrane bioreactons - a review of recent literature [J].
Pollice, A ;
Brookes, A ;
Jefferson, B ;
Judd, S .
DESALINATION, 2005, 174 (03) :221-230
[57]   Predicting limiting flux of skim milk in crossflow microfiltration [J].
Samuelsson, G ;
Huisman, IH ;
Tragardh, G ;
Paulsson, M .
JOURNAL OF MEMBRANE SCIENCE, 1997, 129 (02) :277-281
[58]   Minimizing whey protein retention in cross-flow microfiltration of skim milk [J].
Samuelsson, G ;
Dejmek, P ;
Tragardh, G ;
Paulsson, M .
INTERNATIONAL DAIRY JOURNAL, 1997, 7 (04) :237-242
[59]   Dean vortex membrane microfiltration non-Newtonian viscosity effects [J].
Schutyser, M ;
Belfort, G .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (03) :494-504
[60]   Modeling of transient permeate flux in cross-flow membrane filtration incorporating multiple particle transport mechanisms [J].
Sethi, S ;
Wiesner, MR .
JOURNAL OF MEMBRANE SCIENCE, 1997, 136 (1-2) :191-205