Refrigerant performance evaluation including effects of transport properties and optimized heat exchangers

被引:24
|
作者
Brignoli, Riccardo [1 ]
Brown, J. Steven [2 ]
Skye, Harrison M. [1 ]
Domanski, Piotr A. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Catholic Univ Amer, Washington, DC 20064 USA
关键词
Simulation model; Working fluids; Cycle COP; Heating ventilation and air conditioning HVAC&R; Refrigerants thermophysical properties; PRESSURE-DROP; HORIZONTAL TUBES; 2-PHASE FLOW; CONDENSATION; MODEL;
D O I
10.1016/j.ijrefrig.2017.05.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
Preliminary refrigerant screenings typically rely on using cycle simulation models involving thermodynamic properties alone. This approach has two shortcomings. First, it neglects transport properties, whose influence on system performance is particularly strong through their impact on the performance of the heat exchangers. Second, the refrigerant temperatures in the evaporator and condenser are specified as input, while real-life equipment operates at imposed heat sink and heat source temperatures; the temperatures in the evaporator and condensers are established based on overall heat transfer resistances of these heat exchangers and the balance of the system. The paper discusses a simulation methodology and model that addresses the above shortcomings. This model simulates the thermodynamic cycle operating at specified heat sink and heat source temperature profiles, and includes the ability to account for the effects of thermophysical properties and refrigerant mass flux on refrigerant heat transfer and pressure drop in the air-to-refrigerant evaporator and condenser. Additionally, the model can optimize the refrigerant mass flux in the heat exchangers to maximize the coefficient of performance. The new model is validated with experimental data and its predictions are contrasted to those of a model based on thermodynamic properties alone. Published by Elsevier Ltd.
引用
收藏
页码:52 / 65
页数:14
相关论文
共 50 条
  • [31] Evaluation of ORC modules performance adopting commercial plastic heat exchangers
    Alaez, S. L. Gomez
    Bombarda, P.
    Invernizzi, C. M.
    Iora, P.
    Silva, P.
    APPLIED ENERGY, 2015, 154 : 882 - 890
  • [32] Comparative Evaluation and Performance Analysis of Heat Exchangers Featured with Peened Surface
    Dineshbabu, Chinnadurai
    Sivasankaran, Nallasamy
    Raja, Krishnan Venkatesh
    Venkatesh, Rathinavelu
    JOURNAL OF THERMAL SCIENCE, 2025, 34 (01) : 50 - 61
  • [33] A risk based performance evaluation of plate-and-frame heat exchangers
    Khan, JUR
    Zubair, SM
    HEAT AND MASS TRANSFER, 2003, 39 (04) : 327 - 336
  • [34] Performance evaluation criteria for heat exchangers based on first law analysis
    Yilmaz, M
    Comakli, O
    Yapici, S
    Sara, ON
    JOURNAL OF ENHANCED HEAT TRANSFER, 2005, 12 (02) : 121 - 157
  • [35] PERFORMANCE EVALUATION OF MULTI-STAGE SHELL AND TUBE TRANSPORT MEMBRANE CONDENSER HEAT EXCHANGERS FOR LOW GRADE WASTE HEAT AND WATER RECOVERY
    Soleimanikutanaei, Soheil
    Lin, Cheng-Xian
    Wang, Dexin
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2017, VOL 1, 2017,
  • [36] Heat Transport Optimization in Biogas Systems by innovative Heat Exchangers and Concept Evaluation by using CFD Methods
    Geiger, Chris
    AGRICULTURAL ENGINEERING, 2016, 2016, : 219 - 225
  • [37] Fluid Friction Effects on the Thermodynamic Performance of Spiral Plate Heat Exchangers
    Shirazi, Amir Hossein Sabouri
    Ghodrat, Maryam
    Behnia, Masud
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2022, 36 (03) : 466 - 484
  • [38] Accounting for the effect of the heat exchanger length in the performance evaluation of compact fin and tube heat exchangers
    Ameel, Bernd
    Degroote, Joris
    T'Joen, Christophe
    Huisseune, Henk
    De Schampheleire, Sven
    Vierendeels, Jan
    De Paepe, Michel
    APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) : 544 - 553
  • [39] Effects of liquid refrigerant injection on the performance of a refrigeration system with an accumulator heat exchanger
    Kang, Hoon
    Lee, Sunil
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05): : 883 - 891
  • [40] Influence of grout thermal properties on heat-transfer performance of ground source heat exchangers
    Zhou, Yasu
    Zhang, Yongcai
    Xu, Yongliang
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (05) : 461 - 469