An Assessment on Average Pressure Drop and Dust-Holding Capacity of Hollow-Fiber Membranes in Air Filtration

被引:6
|
作者
Bulejko, Pavel [1 ]
Kristof, Ondrej [2 ]
Dohnal, Miroslav [2 ]
机构
[1] Brno Univ Technol, Fac Mech Engn, Heat Transfer & Fluid Flow Lab, Brno 61669, Czech Republic
[2] ZENA Membranes Sro, Brno 62100, Czech Republic
关键词
hollow-fiber membrane; air filtration; pressure drop; dust-holding capacity; DELIVERING SUSTAINABILITY PROMISE; NANOFIBER FILTER; PERFORMANCE; EFFICIENCY; VELOCITY; QUALITY; USAGE; PM2.5;
D O I
10.3390/membranes11070467
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this work, we tried to analyze dust loading behavior of polypropylene hollow fiber membranes using average pressure drop models. Hollow fiber membranes varying in fiber diameter were loaded with a standardized test dust to simulate particle-polluted air. We measured pressure drop development of the membranes at different flowrates and dust concentrations, and, after each experiment, the dust deposited on the membrane fibers was weighed to obtain dust holding capacity (DHC). The obtained experimental data was analyzed using various average pressure drop models and compared with average pressure drop obtained from pressure drop/dust load dependence using a curve fit. Exponential and polynomial fitting was used and compared. Pressure drop in relation to the dust load followed different trends depending on the experimental conditions and inner fiber diameter. At higher flowrate, the dependence was polynomial no matter what the fiber diameter. However, with higher fiber diameter at lower permeate velocities, the dependence was close to exponential curve and followed similar trends as observed in planar filter media. Dust-holding capacity of the membranes depended on the experimental conditions and was up to 21.4 g. However, higher dust holding capacity was impossible to reach no matter the experiment duration due to self-cleaning ability of the tested membranes.
引用
收藏
页数:15
相关论文
共 41 条
  • [1] AIR SWEEP WATER PERVAPORATION WITH HOLLOW-FIBER MEMBRANES
    KORNGOLD, E
    KORIN, E
    DESALINATION, 1993, 91 (02) : 187 - 197
  • [2] Air separation by integrally asymmetric hollow-fiber membranes
    Feng, XS
    Ivory, J
    Rajan, VSV
    AICHE JOURNAL, 1999, 45 (10) : 2142 - 2152
  • [3] Mixed conducting ceramic hollow-fiber membranes for air separation
    Tan, XY
    Liu, YT
    Li, K
    AICHE JOURNAL, 2005, 51 (07) : 1991 - 2000
  • [4] Variations in backwash efficiency during colloidal filtration of hollow-fiber microfiltration membranes
    Hong, SK
    Krishna, P
    Hobbs, C
    Kim, DH
    Cho, JW
    DESALINATION, 2005, 173 (03) : 257 - 268
  • [5] Perovskite hollow-fiber membranes for the production of oxygen-enriched air
    Wang, HH
    Werth, S
    Schiestel, T
    Caro, A
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (42) : 6906 - 6909
  • [6] MATHEMATICAL AND EXPERIMENTAL-ANALYSIS OF AIR SEPARATION BY HOLLOW-FIBER MEMBRANES
    CHEN, H
    LI, DF
    JIANG, GL
    XU, RX
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1995, 3 (02) : 72 - 81
  • [7] Effect of pressure drop on performance of hollow-fiber membrane module for gas permeation
    Chang, D
    Min, J
    Oh, S
    Moon, K
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 1998, 15 (04) : 396 - 403
  • [8] Effect of pressure drop on performance of hollow-fiber membrane module for gas permeation
    Daejun Chang
    Joonho Min
    Sehern Oh
    Kiho Moon
    Korean Journal of Chemical Engineering, 1998, 15 : 396 - 403
  • [10] An analytical approach to the gas pressure drop in hollow fiber membranes
    Shao, P
    Huang, RYM
    JOURNAL OF MEMBRANE SCIENCE, 2006, 271 (1-2) : 69 - 76