A portable array biosensor

被引:7
|
作者
Golden, JP [1 ]
Shriver-Lake, LC [1 ]
Taitt, CR [1 ]
Fertig, S [1 ]
Sapsford, KE [1 ]
Ligler, FS [1 ]
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
来源
ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES II | 2004年 / 5586卷
关键词
evanescent wave; biosensor; automated fluidics; fluorescence imaging;
D O I
10.1117/12.571310
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An array biosensor developed for performing simultaneous analysis of multiple samples for multiple analytes has been miniaturized and fully automated. The biochemical component of the multi-analyte biosensor consists of a patterned array of biological recognition elements ("capture" antibodies) immobilized on the surface of a planar waveguide. A fluorescence assay is performed on the patterned surface, yielding an array of fluorescent spots. the locations of which are used to identify what analyte is present. Signal transduction is accomplished by means of a diode laser for fluorescence excitation. optical filters and a CCD camera for image capture. A laptop computer controls the miniaturized fluidics system and image capture. Data analysis software has been developed to locate each spot and quantify the fluorescent signal in each spot. The array biosensor is capable of detecting a variety of analytes including toxins, bacteria and viruses and shows minimal interference from complex physiological sample matrices such whole blood and blood components, fecal matter, saliva, nasal secretions, and urine. Some results from recent field trials are presented.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 50 条
  • [31] Portable evanescent wave fiber biosensor for highly sensitive detection of Shigella
    Xiao, Rui
    Rong, Zhen
    Long, Feng
    Liu, Qiqi
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 132 : 1 - 5
  • [32] A Portable Surface Plasmon Resonance Biosensor for Rapid Detection of Salmonella typhimurium
    Hoang Hiep Nguyen
    Yi, So Yeon
    Woubit, Abdela
    Kim, Moonil
    APPLIED SCIENCE AND CONVERGENCE TECHNOLOGY, 2016, 25 (03): : 61 - 65
  • [34] A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array
    Manickam, Arun
    Chevalier, Aaron
    McDermott, Mark
    Ellington, Andrew D.
    Hassibi, Arjang
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2010, 4 (06) : 379 - 390
  • [35] Multiplexed measurement of serum antibodies using an array biosensor
    Moreno-Bondi, MC
    Taitt, CR
    Shriver-Lake, LC
    Ligler, FS
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (10) : 1880 - 1886
  • [36] Nanostructured Biosensor of Cobalt Line Array on Permalloy Film
    Kuo, Tzu-Wen
    Huang, Hao-Ting
    Chiang, Chia-Wei
    Liao, Kuei-Tien
    Wei, Zung-Hang
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (07) : 4040 - 4043
  • [37] Imaging array SPR biosensor immunoassays for sulfamethoxazole and sulfamethazine
    Li, Hui
    Cui, Da Fu
    Liang, Jin Qing
    Cai, Hao Yuan
    Wang, Yu Jie
    CHINESE CHEMICAL LETTERS, 2006, 17 (11) : 1481 - 1484
  • [38] Biosensor Array Microsystem on a CMOS Amperometric Readout Chip
    Liu, X.
    Li, L.
    Awate, B.
    Worden, R. M.
    Reguera, G.
    Mason, A. J.
    2011 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2011, : 305 - 308
  • [39] Development, Validation, and Application of a Portable SPR Biosensor for the Direct Detection of Insecticide Residues
    Yang, Gilmo
    Cho, Nam-Hong
    FOOD SCIENCE AND BIOTECHNOLOGY, 2008, 17 (05) : 1038 - 1046
  • [40] General purpose, field-portable cell-based biosensor platform
    Gilchrist, KH
    Barker, VN
    Fletcher, LE
    DeBusschere, BD
    Ghanouni, P
    Giovangrandi, L
    Kovacs, GTA
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (7-8) : 557 - 564