摘要
Objective: The study compares resorbable versus titanium fixation systems for their aesthetic and functional outcome in the treatment of zygomatic fractures. Methods: Twenty-seven patients who required operative reduction and internal fixation for zygomatic fractures were studied in the period from April 2007 to March 2008. Fourteen patients who had fixation with resorbable plate/screws (group A) were compared with 13 patients fixed with titanium plates/screws (group B). The aesthetic outcome was evaluated by an overall self-satisfaction score at 2, 4, and 6 weeks and then at 6 months and 1 year postoperative interval, and the degree of displacement from computed tomographic facial bones were compared preoperatively and 1 year postoperatively. The functional outcome was evaluated by a self-satisfaction scoring systemandmaximummouth opening during the same time intervals. Results: The outcome showed that the 2 groups were matched in age, sex ratio, fracture severity, total displacement with 5 sutures, and aesthetic scores preoperatively (P > 0.05). The subjective evaluation by patients for functional satisfaction and overall satisfaction all showed lower satisfaction of absorbable group when compared to titanium group within a postoperative 4-week period, but the satisfaction was similar for both groups after 4 weeks. Therewas no significant difference between the 2 groups at each measured time period. Postoperative total displacement and aesthetic score demonstrated great improvement in fracture reduction and long-term stability in both groups. Conclusion: There is no significant difference in the outcome between resorbable and titanium plates/screws in fixation of zygomatic fractures. These findings together with the advantages of biodegradable fixation validate its use in fixing these fractures with minimal morbidity.
引用
收藏
页码:S85 / S90
页数:6
相关论文
共 27 条
[1]   Absorbable Plate Strength Loss During Molding [J].
Ballard, Tiffany N. S. ;
Kelly, Kevin J. ;
Zaydfudim, Victor ;
Walcutt, Noah L. ;
Lahijani, Soheil S. ;
Shack, R. Bruce ;
Thayer, Wesley P. .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (03) :644-647
[2]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[3]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[4]   A retrospective study of zygomatico-orbital complex and/or zygomatic arch fractures over a 71-month period [J].
Bertelli Trivellato, Priscila Faleiros ;
Manfrin Arnez, Maya Fernanda ;
Sverzut, Cassio Edvard ;
Trivellato, Alexandre Elias .
DENTAL TRAUMATOLOGY, 2011, 27 (02) :135-142
[5]   RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES [J].
BOS, RRM ;
BOERING, G ;
ROZEMA, FR ;
LEENSLAG, JW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) :751-753
[6]   Self-reinforced biodegradable plates and screws for fixation of zygomatic fractures [J].
Enislidis, G ;
Yerit, K ;
Wittwer, G ;
Köhnke, R ;
Schragl, S ;
Ewers, R .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2005, 33 (02) :95-102
[7]   Fixation of zygomatic fractures with a biodegradable copolymer osteosynthesis system: short- and long-term results [J].
Enislidis, G ;
Lagogiannis, G ;
Wittwer, G ;
Glaser, C ;
Ewers, R .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (01) :19-26
[8]  
Eppley BL, 2004, PLAST RECONSTR SURG, V114, P850, DOI 10.1097/01.PRS.0000132856.69391.43
[9]   Zygomaticomaxillary fracture repair with resorbable plates and screws [J].
Eppley, BL .
JOURNAL OF CRANIOFACIAL SURGERY, 2000, 11 (04) :377-385
[10]  
EWERS R, 1985, AM ASS ORAL MAXILLOF, V67, P23