The influence of varying the number of characters per row on the accuracy and reproducibility of the ETDRS visual acuity chart

被引:7
作者
Shamir, Reuben R. [1 ]
Friedman, Yael G. [2 ]
Joskowicz, Leo [1 ]
Mimouni, Michael [2 ]
Blumenthal, Eytan Z. [2 ]
机构
[1] Hebrew Univ Jerusalem, Sch Engn & Comp Sci, Jerusalem, Israel
[2] Rambam Med Ctr, Dept Ophthalmol, POB 9602, IL-31096 Haifa, Israel
关键词
ETDRS; Characters; Number; Row; Visual acuity; Accuracy; Reproducibility; ROUTINE CLINICAL-PRACTICE; COMPACT REDUCED LOGMAR; COMPUTER-SIMULATION; RETEST VARIABILITY; FIELD PROGRESSION; THRESHOLD; SENSITIVITY; STRATEGIES;
D O I
10.1007/s00417-015-3252-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background As part of an effort to improve upon the Snellen chart, we provide a standardized version of the ETDRS chart utilizing five characters in each row. The choice of five characters contradicts the recommended ten characters per row determined by the NAS-NRC, a committee established to provide guidelines for testing visual acuity. We set out to quantify the influence of varying the number of characters per line on the ETDRS chart with respect to the accuracy and reproducibility of visual acuity measurement. Methods Eleven different ETDRS charts were created, each with a different number of characters appearing in each row. A computer simulation was programmed to run 10,000 virtual patients, each with a unique visual acuity, false-positive and false-negative error value. Results Accuracy and reproducibility were found to roughly correlate with the number of characters present in each row, such that charts with 1, 3, 5, 7, 9, and 11 characters per row provided accuracy of 0.164, 0.094, 0.078, 0.073, 0.071, and 0.070 logMAR, respectively. A non-linear relationship was observed, with little improvement found beyond seven characters per row. In addition, charts with an even number of characters per row provided higher accuracy than their greater-number odd counterparts. In certain instances, accuracy and reproducibility were not well correlated. Conclusions Increasing the number of characters per row in the ETDRS chart provides a trade-off between accuracy and test duration. An optimized chart layout would take these findings into account, allowing for the use of different chart layouts for clinical versus research settings.
引用
收藏
页码:971 / 976
页数:6
相关论文
共 24 条
[1]  
Anderson DR, 1999, AUTOMATED STATIC PER, p[10, 121, 281, 317]
[2]  
BAILEY IL, 1976, AM J OPTOM PHYS OPT, V53, P740
[3]   Repeatability of mesopic visual acuity measurements using high- and low-contrast ETDRS letter charts [J].
Barrio, Ana ;
Antona, Beatriz ;
Puell, Maria C. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (05) :791-795
[4]  
Committee on vision, 1980, 39 NAT AC SCI NAT RE, V41, P103
[5]   A comparison of Lea Symbol vs ETDRS letter distance visual acuity in a population of young children with a high prevalence of astigmatism [J].
Dobson, Velma ;
Clifford-Donaldson, Candice E. ;
Miller, Joseph M. ;
Garvey, Katherine A. ;
Harvey, Erin M. .
JOURNAL OF AAPOS, 2009, 13 (03) :253-257
[6]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[7]  
Gardiner SK, 2002, INVEST OPHTH VIS SCI, V43, P1400
[8]  
Kniestedt C, 2003, OPHTHALMOL CLIN N AM, V16, pv
[9]  
Kniestedt Christoph, 2003, Ophthalmol Clin North Am, V16, P155, DOI 10.1016/S0896-1549(03)00013-0
[10]   Assessing visual acuity across five disease types: ETDRS charts are faster with clinical outcome comparable to Landolt Cs [J].
Koenig, Simone ;
Tonagel, Felix ;
Schiefer, Ulrich ;
Bach, Michael ;
Heinrich, Sven P. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (07) :1093-1099