Experimental seismic performance of CFDST- steel beam frames with different construction details

被引:25
作者
Hu, Yi [1 ]
Zhao, Junhai [1 ]
Zhang, Dongfang [1 ]
Chen, Chen [1 ]
机构
[1] Changan Univ, Sch Civil Engn, Xian 710061, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled double-skin steel tube (CFDST); Composite structures; Moment-resisting frame; Construction details; Prefabricated construction technology; Seismic performance; CFT COLUMN; COMPOSITE JOINTS; TUBULAR COLUMNS; CFST COLUMN; BEHAVIOR; SQUARE; CONNECTIONS; DESIGN; TUBES;
D O I
10.1016/j.jcsr.2019.105736
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper proposes a novel splicing-type column-to-column connection and a novel block-strengthened beam-to-column connection to realize fully-prefabricated construction of concrete-filled double-skin steel tube (CFDST)- steel beam frames. To investigate the effects of such novel connections on seismic behavior of CFDST frames, a test program on three 1/2-scaled single-bay and single-story specimens was presented. Such specimens were constructed with different levels in using the novel connections and were tested subjected to cyclic loads. Among the failure modes, hysteretic curves, ultimate capacity and ductility of these specimens were obtained and compared in the test program. The results show that: (1) the proposed block-strengthened beam-to-column connection could enhance the capacity and ductility of the CFDST frames effectively; (2) the splicing type column-to-column connection has very few influences on capacity and initial stiffness on the CFDST frame, but it would slightly reduce the ductility of the CFDST frame; (3) three mechanical phases were proposed for analysis of the CFDST frames, and theoretical calculation was proposed to predict ultimate capacity of the CFDST frames and was validated by the test results. The proposed novel type of connections provide an effective plan to realize fully-prefabricated construction of CFDST structures and could be a feasible choice for engineering practice. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 39 条
[1]  
American Institute of Steel Construction, 2016, 35816 ANSIAISC
[2]  
[Anonymous], 2002, 228 GBT
[3]  
[Anonymous], 2010, 50011 GB
[4]  
[Anonymous], 1997, 101 JGJ
[5]   Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors [J].
Ataei, Abdolreza ;
Bradford, Mark A. ;
Valipour, Hamid R. .
ENGINEERING STRUCTURES, 2015, 99 :616-630
[6]   Modelling of the panel zone in steel and composite moment frames [J].
Castro, JM ;
Elghazouli, AY ;
Izzuddin, BA .
ENGINEERING STRUCTURES, 2005, 27 (01) :129-144
[7]   Composite frame of circular CFST column to steel-concrete composite beam under lateral cyclic loading [J].
Ding, Fa-xing ;
Yin, Guo-an ;
Jiang, Li-zhong ;
Bai, Yu .
THIN-WALLED STRUCTURES, 2018, 122 :137-146
[8]   Experimental behavior of steel beam to CFT column connections [J].
Elremaily, A ;
Azizinamini, A .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (10) :1099-1119
[9]   Performance of concrete-filled double-skin circular tubes in compression [J].
Essopjee, Y. ;
Dundu, M. .
COMPOSITE STRUCTURES, 2015, 133 :1276-1283
[10]  
Eurocode 4, 2005, DES STEEL STRUCT 1, P1