Threats to water supply systems have increased in number and intensity. Natural disasters such as earthquakes have caused different types of damage to water distribution networks (WDN), particularly for those with aged infrastructure. This paper investigates the resilience of an existing water distribution network under seismic hazard. An earthquake generation model coupled with a probabilistic flow-based pressure driven demand hydraulic model is investigated and applied to an existing WDN. A total of 27 earthquake scenarios and 2 repair strategies were simulated. The analysis examined hydraulic resilience metrics such as pressure, leak demand, water serviceability, and population impacted. The results show that nodal pressure drops below nominal pressure and reaches zero in some earthquake scenarios. Leak demand could reach to more than 10 m(3)/s within hours following an earthquake. Water serviceability drops to a low of 40% and population impacted reaches up to 90% for a 6.5 M earthquake, for example. This study highlights and quantifies vulnerabilities within the simulated WDN. The tools outlined here illustrate an approach that can: (1) ultimately help to better inform utility water safety plans, and (2) prepare proactive strategies to mitigate/repair before a hazard of this nature occurs.
引用
收藏
页数:14
相关论文
共 47 条
[1]   Serviceability of earthquake-damaged water systems: Effects of electrical power availability and power backup systems on system vulnerability [J].
Adachi, Takao ;
Ellingwood, Bruce R. .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 2008, 93 (01) :78-88
[2]  
[Anonymous], 1996, P 4 JAPAN US WORKSHO
[3]  
[Anonymous], 2019, Earthquake scenario for Weinan, China
[4]  
[Anonymous], 2001, Seismic Fragility Formulations for Water Systems, Part-1-Guidelines Reports
[5]  
[Anonymous], 1917, Sun
[6]   A REVIEW OF THE RESPONSE OF BURIED PIPELINES UNDER SEISMIC EXCITATIONS [J].
ARIMAN, T ;
MULESKI, GE .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1981, 9 (02) :133-151
[7]  
Bonneau L., 2009, MCEER090003
[8]  
Carter L., 2014, PERS INDIV DIFFER
[9]  
Clinton W.J., 1996, Federal Register, V61, P37347
[10]  
Crowl A., 2011, CHEM PROCESS SAFETY, V3, p720p