Non-invasive monitoring of dough mixing by near infrared spectroscopy

被引:106
|
作者
Wesley, IJ [1 ]
Larsen, N
Osborne, BG
Skerritt, JH
机构
[1] CSIRO Plant Ind, Grain Qual Res Lab, N Ryde, NSW 2113, Australia
[2] Crop & Food Res, N Ryde, NSW 2113, Australia
[3] BRI Australia Ltd, N Ryde, NSW 2113, Australia
关键词
dough; near infrared; mixing; spectroscopy;
D O I
10.1006/jcrs.1997.0151
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A novel, non-invasive method of monitoring dough development using a diode array near infrared spectrometer has been developed. The variation in two specific absorbance wavelengths in the second derivative spectrum (1160 nm and 1200 nm) as the dough is mixed is shown to follow the same trend as mixer power consumption. Both absorbance features show a reduction in peal; area as dough mixing progresses, reaching a minimum at optimum dough development, and an increase as the dough mixing continues past peak mixer power consumption. Consistent results were obtained for un-yeasted and Full formula doughs made from flours of different strengths using three different laboratory mixers of different mixing action (spiral, z-arm and pin). In the case of the z-arm and pin mixers, the NIR mixing curves predicted longer mixing times than the power consumption curves, and both methods differentiated between flours of different strength. The spiral mixer showed no statistical difference between the mixing times measured by each method, and further, there was no statistical difference between the mixing times for each flour when measured using either method. These differences may be due to mixer design or mixing intensity. The data presented shows the potential of the technique for providing information on the chemical processes that occur during dough development in relation to flour strength and mixing action and intensity. (C) 1998 Academic Press Limited.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [41] A non-invasive diagnostic tool for cellulose acetate films using a portable miniaturized near infrared spectrometer
    Lozano, Marco Valente Chavez
    Catelli, Emilio
    Sciutto, Giorgia
    Prati, Silvia
    Genorini, Emiliano
    Mazzeo, Rocco
    TALANTA, 2023, 255
  • [42] Near-infrared spectroscopy for monitoring muscle oxygenation
    Boushel, R
    Piantadosi, CA
    ACTA PHYSIOLOGICA SCANDINAVICA, 2000, 168 (04): : 615 - 622
  • [43] Non-invasive fermentation analysis using an artificial neural network algorithm for processing near infrared spectra
    Li, Y
    Brown, CW
    Sun, FM
    McCrady, JW
    Traxler, RW
    Lo, SC
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 1999, 7 (02) : 101 - 108
  • [44] Local measurement of venous saturation in tissue with non-invasive, near-infrared respiratory-oximetry
    Franceschini, MA
    Zourabian, A
    Moore, JB
    Arora, A
    Fantini, S
    Boas, DA
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IV, 2001, 4250 : 164 - 170
  • [45] Monitoring biodiesel fuel quality by near infrared spectroscopy
    Felizardo, Pedro
    Baptista, Patricia
    Uva, Margarida Sousa
    Menezes, Jose C.
    Correia, M. Joana Neiva
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2007, 15 (02) : 97 - 105
  • [46] Non-Invasive Blood Glucose Monitoring Technology: A Review
    Tang, Liu
    Chang, Shwu Jen
    Chen, Ching-Jung
    Liu, Jen-Tsai
    SENSORS, 2020, 20 (23) : 1 - 32
  • [47] Innovation in Non-Invasive Diagnosis and Disease Monitoring for Meningiomas
    Korte, Brianna
    Mathios, Dimitrios
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (08)
  • [48] Usefulness and limits of near infrared spectroscopy monitoring during endovascular neuroradiologic procedures
    Mazzeo, A. T.
    Di Pasquale, R.
    Settineri, N.
    Bottari, G.
    Granata, F.
    Farago, G.
    Pitrone, A.
    Longo, M.
    Santamaria, L. B.
    MINERVA ANESTESIOLOGICA, 2012, 78 (01) : 34 - 45
  • [49] Near-Infrared Spectroscopy in the Monitoring of Adult Traumatic Brain Injury: A Review
    Davies, David J.
    Su, Zhangjie
    Clancy, Michael T.
    Lucas, Samuel J. E.
    Dehghani, Hamid
    Logan, Ann
    Belli, Antonio
    JOURNAL OF NEUROTRAUMA, 2015, 32 (13) : 933 - 941
  • [50] Non-invasive gas monitoring in newborn infants using diode laser absorption spectroscopy: A case study
    Lundin, Patrik
    Svanberg, Emilie Krite
    Cocola, Lorenzo
    Lewander, Marta
    Andersson-Engels, Stefan
    Jahr, John
    Fellman, Vineta
    Svanberg, Katarina
    Svanberg, Sune
    OPTICAL DIAGNOSTICS AND SENSING XII: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE IV, 2012, 8229