Investigation of concrete encased steel composite columns at elevated temperatures

被引:37
作者
Ellobody, Ehab [2 ]
Young, Ben [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
[2] Tanta Univ, Fac Engn, Dept Struct Engn, Tanta, Egypt
关键词
Concrete encased steel; Composite columns; Elevated temperatures; Finite element; Modelling; Fire resistance; Structural fire design; ANALYTICAL-MODEL; BEHAVIOR; DESIGN;
D O I
10.1016/j.tws.2010.03.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a nonlinear 3-D finite element model investigating the behaviour of concrete encased steel composite columns at elevated temperatures. The composite columns were pin-ended axially loaded columns having different cross-sectional dimensions, different structural steel sections, different coarse aggregates and different load ratios during fire. The nonlinear material properties of steel, concrete, longitudinal and transverse reinforcement bars as well as the effect of concrete confinement at ambient and elevated temperatures were considered in the finite element models. The interface between the steel section and concrete, the longitudinal and transverse reinforcement bars, and the reinforcement bars and concrete were also considered allowing the bond behaviour to be modelled and the different components to retain its profile during the deformation of the column. The initial overall (out-of-straightness) geometric imperfection was carefully included in the model. The finite element model has been validated against published tests conducted at elevated temperatures. The time-temperature relationships, deformed shapes at failure, time-axial displacement relationships, failure modes and fire resistances of the columns were evaluated by the finite element model. It has been shown that the finite element model can accurately predict the behaviour of the columns at elevated temperatures. Furthermore, the variables that influence the fire resistance and behaviour of the composite columns comprising different load ratios during fire, different coarse aggregates and different slenderness ratios were investigated in parametric studies. It is shown that the fire resistance of the columns generally increases with the decrease in the column slenderness ratio as well as the increase in the structural steel ratio. It is also shown that the time-axial displacement relationship is considerably affected by the coarse aggregate. The fire resistances of the composite columns obtained from the finite element analyses were compared with the design values obtained from the Eurocode 4 for composite columns at elevated temperatures. It is shown that the EC4 is conservative for all the concrete encased steel composite columns, except for the columns having a load ratio of 0.5 as well as the columns having a slenderness ratio of 0.69 and a load ratio of 0.4. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:597 / 608
页数:12
相关论文
共 41 条
[1]  
[Anonymous], 1979, ENG J AISC, V16, P101
[2]  
[Anonymous], 199211 BS EN BRIT ST
[3]  
[Anonymous], 2008, ABAQUS STAND US MAN, V3
[4]  
[Anonymous], 2008, ABAQUS STAND US MAN, V1
[5]  
[Anonymous], 2002, 199112 BS EN BRIT ST
[6]  
[Anonymous], 2005, 199412 BS EN BRIT ST
[7]  
[Anonymous], 2004, 199411 BS EN BRIT ST
[8]  
[Anonymous], 2008, ABAQUS STAND US MAN, V2
[9]  
Anslijn R., 1974, MT89 CRIF
[10]   Whole-building behaviour of bonded post-tensioned concrete floor plates exposed to fire [J].
Bailey, Colin G. ;
Ellobody, Ehab .
ENGINEERING STRUCTURES, 2009, 31 (08) :1800-1810