Preclinical evaluation of the Dynesys posterior spinal stabilization system: a nonhuman primate model

被引:12
|
作者
Cunningham, Bryan W. [1 ]
Dawson, John M. [2 ]
Hu, Nianbin [1 ]
Kim, Seok Woo [1 ]
McAfee, Paul C. [1 ]
Griffith, Steven L. [2 ]
机构
[1] Jordan Ctr, Orthopaed Spinal Res Lab, St Joseph Med Ctr, Scoliosis & Spine Ctr, Towson, MD 21204 USA
[2] Zimmer Inc, Warsaw, IN 46581 USA
来源
SPINE JOURNAL | 2010年 / 10卷 / 09期
关键词
Facet arthrosis; Spine kinematics; Dynamic stabilization; Nonfusion; TOTAL DISC REPLACEMENT; LUMBAR SPINE; IN-VITRO;
D O I
10.1016/j.spinee.2010.04.005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Posterior dynamic spinal stabilization systems are intended to restore near-normal biomechanical function of the spine without inducing unnatural stresses to the spinal elements or eliciting a histopathological response. These devices must resist loosening within the challenging biomechanical environment of the lumbar spine. PURPOSE: To determine the biomechanical effects of the Dynesys dynamic stabilization system (Zimmer, Inc., Warsaw, IN, USA) in the acute postoperative period and after 6 and 12 months in vivo; to examine the facet joints at the same postoperative intervals for signs of degeneration; and to measure the incidence of screw loosening after in vivo loading. STUDY DESIGN/SETTING: This was an in vitro and in vivo animal survival study. METHODS: Fourteen baboons were used. Eight animals underwent survival surgery to implant a posterior dynamic stabilization system spanning two lumbar levels. Six animals were sacrificed acutely, and their spines were biomechanically tested in the intact condition and with instrumentation implanted as described above. Six animals in the survival group were sacrificed at 6 months postoperatively and two animals at 12 months postoperatively. Their spines were biomechanically tested with instrumentation in situ and explanted. The facets were then processed using undecalcified technique. Microradiographs of the facets were examined for signs of arthrosis, inflammation, and degenerative changes. RESULTS: The range of flexion-extension motion for the acute group of instrumented spines was 27% of the intact condition. After 6 months with instrumentation in situ, flexion-extension was 56% of the intact condition. After 12 months with instrumentation in situ, flexion-extension was 70% of the intact condition. With instrumentation explanted, flexion-extension at 6 and 12 months was not different from the intact condition (p>.05). Similar results were observed for lateral bending. There were no significant differences in axial rotation between any groups at any time point (p>.05). The facet joints at the operative and adjacent levels exhibited normal articular cartilage at both the 6- and 12-month postoperative time points. There was no evidence of facet arthrosis in any animal. At 6 months postoperatively, 0 of 36 screws exhibited radiolucency at the bone-metal interface. At 12 months postoperatively, 3 of 12 screws exhibited radiolucency. CONCLUSIONS: After 12 months in vivo, spinal motions were stabilized by the dynamic instrumentation system. No facet arthrosis was observed at 6 and 12 months postoperatively. Explantation of the instrumentation restored motion to intact levels. A 25% rate of screw loosening (3 of 12 screws) was observed at the 12-month postoperative time point. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:775 / 783
页数:9
相关论文
共 50 条
  • [21] Animal Models of Neurologic Disorders: A Nonhuman Primate Model of Spinal Cord Injury
    Nout, Yvette S.
    Rosenzweig, Ephron S.
    Brock, John H.
    Strand, Sarah C.
    Moseanko, Rod
    Hawbecker, Stephanie
    Zdunowski, Sharon
    Nielson, Jessica L.
    Roy, Roland R.
    Courtine, Gregoire
    Ferguson, Adam R.
    Edgerton, V. Reggie
    Beattie, Michael S.
    Bresnahan, Jacqueline C.
    Tuszynski, Mark H.
    NEUROTHERAPEUTICS, 2012, 9 (02) : 380 - 392
  • [22] Establishment of graded spinal cord injury model in a nonhuman primate: The common marmoset
    Iwanami, A
    Yamane, J
    Katoh, H
    Nakamura, M
    Momoshima, S
    Ishii, H
    Tanioka, Y
    Tamaoki, N
    Nomura, T
    Toyama, Y
    Okano, H
    JOURNAL OF NEUROSCIENCE RESEARCH, 2005, 80 (02) : 172 - 181
  • [23] Animal Models of Neurologic Disorders: A Nonhuman Primate Model of Spinal Cord Injury
    Yvette S. Nout
    Ephron S. Rosenzweig
    John H. Brock
    Sarah C. Strand
    Rod Moseanko
    Stephanie Hawbecker
    Sharon Zdunowski
    Jessica L. Nielson
    Roland R. Roy
    Gregoire Courtine
    Adam R. Ferguson
    V. Reggie Edgerton
    Michael S. Beattie
    Jacqueline C. Bresnahan
    Mark H. Tuszynski
    Neurotherapeutics, 2012, 9 : 380 - 392
  • [24] Dynamic stabilization of the lumbar spine using the Dynesys Spinal System: Early results of the multicenter trial
    Davis, Reginald J.
    Maxwell, James
    Delamarter, Rick
    Wingate, Jeffrey
    Sherman, John
    Welch, William C.
    NEUROSURGERY, 2006, 59 (02) : 463 - 463
  • [25] The Dynesys lumbar spinal stabilization system - A preliminary report on positional magnetic resonance imaging findings
    Beastall, James
    Karadimas, Efthimios
    Siddiqui, Manal
    Nicol, Malcolm
    Hughes, Justin
    Smith, Francis
    Wardlaw, Douglas
    SPINE, 2007, 32 (06) : 685 - 690
  • [26] Evaluation of a nonhuman primate model to study circadian rhythms of calcium metabolism
    Hotchkiss, CE
    Jerome, CP
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1998, 275 (02) : R494 - R501
  • [27] A nonhuman primate model of menopause: Evaluation of reproductive cycling and hormones.
    Handy, AM
    Black, A
    Ingram, DK
    Roth, GS
    Tilmont, EM
    Lane, MA
    AGE, 1999, 22 (03) : 129 - 129
  • [28] Determination and Evaluation of Hypertension in a Nonhuman Primate Model of Type 2 Diabetes
    Liang, Yinan
    Yang, Zunyuan
    Liang, Zhigang
    Yu, Yanqin
    Chen, Yuanhai
    Yao, Zunwei
    Shen, Yubo
    Hansen, Barbara C.
    Gong, Li
    Zeng, Wen
    DIABETES, 2017, 66 : A633 - A633
  • [29] INVIVO EVALUATION OF ARTIFICIAL SURFACES WITH A NONHUMAN PRIMATE MODEL OF ARTERIAL THROMBOSIS
    HANSON, SR
    HARKER, LA
    RATNER, BD
    HOFFMAN, AS
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1980, 95 (02): : 289 - 304
  • [30] Opiates, immune system, acquired immunodeficiency syndrome, and nonhuman primate model
    Noel, Richard J., Jr.
    Rivera-Amill, Vanessa
    Buch, Shilpa
    Kumar, Anil
    JOURNAL OF NEUROVIROLOGY, 2008, 14 (04) : 279 - 285