Two-phase pressure drop of refrigerants during flow boiling in small channels: an experimental investigation and correlation development

被引:254
作者
Tran, TN
Chyu, MC
Wambsganss, MW
France, DM
机构
[1] Argonne Natl Lab, Div Energy Technol, Argonne, IL 60439 USA
[2] Texas Tech Univ, Dept Mech Engn, Lubbock, TX 79409 USA
[3] Univ Illinois, Dept Mech Engn, Chicago, IL 60607 USA
关键词
two-phase pressure drop; small channels; refrigerants; correlations;
D O I
10.1016/S0301-9322(99)00119-6
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Two-phase flow pressure drop measurements were made during a phase-change heat transfer process with three refrigerants (R-134a, R-12, and R-113) at six different pressures ranging from 138 to 856 kPa, and in two sizes of round tubes (2.46 and 2.92 mm inside diameters) and one rectangular channel (4.06 x 1.7 mm). The data were compared with those from large tubes under similar conditions, and state-of-the-art correlations were evaluated using the R-134a data. The state-of-the-art large-tube correlations failed to satisfactorily predict the experimental data, The data were used to develop a new correlation for two-phase pressure drop during flow boiling in small channels. The correlation was then tested against the experimental data for the three refrigerants; the error was +/- 20%. (C) 2000 Elsevier Science Ltd. All rights reserved.