Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy

被引:11
|
作者
Arnalich-Montiel, Francisco [1 ]
Ortiz-Toquero, Sara [2 ]
Auladell, Clara [1 ]
Couceiro, Ana [1 ]
机构
[1] Ramon y Cajal Univ Hosp, Dept Ophthalmol, Carretera Colmenar Viejo Km 9,100, Madrid 28034, Spain
[2] Univ Valladolid, Sch Optometry, IOBA Eye Inst, Optometry Res Grp, Valladolid, Spain
关键词
Fuchs endothelial dystrophy; DSAEK; DMEK; optical coherence tomography; Scheimpflug tomography; corneal thickness; REPEATABILITY; PACHYMETRY; ANTERIOR; PENTACAM; KERATOCONUS;
D O I
10.1097/ICO.0000000000001530
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Methods: Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland- Altman analysis. Results: Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation <= 0.60%, <= 0.36%, <= 0.43%, <= 1.09%, and <= 0.48%, respectively) than the Scheimpflug (coefficient of variation <= 1.15%, <= 0.92%, <= 1.10%, <= 1.25%, and <= 1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P < 0.01) except in the DSAEK group (P <= 0.51); however, SS-OCT underestimated all measurements. Conclusions: SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [1] Assessment of corneal thickness measurement using swept-source Fourier-domain anterior segment optical coherence tomography and Scheimpflug camera
    Huang, Jinhai
    Feng, Yifan
    Wang, Qinmei
    Pesudovs, Konrad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07) : 1305 - 1306
  • [2] Corneal Analysis with Swept Source Optical Coherence Tomography in Patients with Coexisting Cataract and Fuchs Endothelial Corneal Dystrophy
    Nowinska, Anna
    Chlasta-Twardzik, Edyta
    Dembski, Michal
    Ulfik-Dembska, Klaudia
    Wylegala, Edward
    DIAGNOSTICS, 2021, 11 (02)
  • [3] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [4] Agreement Between Swept-source Optical Coherence Tomography and Rotating Scheimpflug Camera in Measurement of Corneal Parameters in Normal and Keratoconic Eyes
    Ghassemi, Hamed
    Zarei-Ghanavati, Mehran
    Khastavan, Mina
    Atighehchian, Mehrnaz
    Khorasani, Abbas Azimi
    Latifi, Golshan
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2023, 18 (04) : 386 - 395
  • [5] Scheimpflug Versus Optical Coherence Tomography to Detect Subclinical Corneal Edema in Fuchs Endothelial Corneal Dystrophy
    Augustin, Victor A.
    Koppe, Max K.
    Son, Hyeck-Soo
    Meis, Jan
    Yildirim, Timur M.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    CORNEA, 2022, 41 (11) : 1378 - 1385
  • [6] Comparison of Anterior Segment Measurements between Scheimpflug-Placido Camera and New Swept-source Optical Coherence Tomography
    Choe, Gon Soo
    Kim, Kook Young
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (01): : 10 - 19
  • [7] Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging
    Chan, Tommy C. Y.
    Biswas, Sayantan
    Yu, Marco
    Jhanji, Vishal
    ACTA OPHTHALMOLOGICA, 2017, 95 (06) : E486 - E494
  • [8] Corneal thickness mapping by 3D swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Malori, Marianna
    Scaroni, Patrizia
    Leaci, Rosachiara
    Delfini, Elisabetta
    Macaluso, Claudio
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e452 - e457
  • [9] Scheimpflug Tomography as a Predictor of Corneal Edema After Phacoemulsification in Fuchs Endothelial Corneal Dystrophy
    Eleiwa, Taher K.
    Mohammed, Mona Abd El-Azim
    Bayoumy, Ahmed Sherin M.
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 2303 - 2311
  • [10] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971