Interest of 123I-mIBG cardiac tomoscintigraphy coupled with myocardial perfusion in diagnosis of multiple system atrophy

被引:0
作者
Andriamisandratsoa, N. [1 ]
Anheim, M. [2 ]
Tranchant, C. [2 ]
Grucker, D. [1 ]
Namer, I. J. [1 ]
机构
[1] Hop Univ Strasbourg, Serv Biophys & Med Nucl, Hop Hautepierre, F-67098 Strasbourg 09, France
[2] Hop Univ Strasbourg, Dept Neurol, F-67098 Strasbourg 09, France
来源
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE | 2010年 / 34卷 / 04期
关键词
I-123-mIBG; Tc-99m-tetrofosmin; Cardiac tomoscintigraphy; Multiple system atrophy; Parkinson's disease; PURE AUTONOMIC FAILURE; PARKINSONS-DISEASE; SYMPATHETIC DENERVATION; MIBG SCINTIGRAPHY; METAIODOBENZYLGUANIDINE; DEGENERATION; DIFFERENTIATION; PHENOTYPE; SEVERITY; DEMENTIA;
D O I
10.1016/j.mednuc.2010.01.007
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objective. - The aim of this prospective study is to assess the pertinence of using I-123-mIBG myocardial tomoscintigraphy coupled with perfusion scintigraphy as a diagnostic tool, to discriminate between multiple system atrophy (MSA) and idiopathic Parkinson's disease (PD) at first guided by clinical data and L-DOPA tests. Material and methods. - Forty patients, aged from 43 to 78 years (median 62 years) with Parkinson's syndrome were studied. Nineteen had a diagnosis of PD (criteria of brain bank) and 21 AMS (Gibbs criteria). All were given test to acute L-DOPA. Chest-centered planar imaging (128 x 128 matrix, 5 minutes of duration) is performed at 1 hour and 4 hours after injection of 220 MBq of I-123-mIBG, in addition a non-synchronised tomoscintigraphy (64 x 64 matrix, 32 images of 50 seconds, zoom 1.45) was performed after the 4th hour and 15 minutes after injection of 200 to 400 MBq of Tc-99m-tetrofosmin. Besides neurological data, the parameters retained for comparison purposes with I-123-mIBG cardiac tomoscintigraphy were patients' age, duration of disease and L-DOPA test results. Two regions of interest (ROI) identical in size and in shape are used for I-123-mIBG uptake quantifications (H/M and washout [Wo]). The first one was placed in projection of mediastinum (M) and the other one in projection of heart (H). Results. - We found an overall decreased uptake of the myocardial I-123-mIBG without perfusion abnormality in 15 of 19 patients with PD and 11 among them were L-DOPA sensitive (L-DOPA test greater than 30%). Normal tracer uptake with I-123-mIBG associated with an almost quite normal perfusion was seen in 15 of 21 patients with MSA and they were little or not L-DOPA sensitive (L-DOPA test less than 30%). Therefore, 10 discordant cases (25%) between cardiac scintigraphy and clinical evolution of disease with also discordant L-DOPA tests were observed. In the PD group, quantification of data enhanced the diagnostic decision with low heart to mediastinum ratio (HIM) (1.32 +/- 0.15 at the early stage and 1.25 +/- 0.13 at the later stage). In the MSA group, the uptake of I-123-mIBG (1.66 +/- 0.43 at the early stage and 1.72 +/- 0.42 at the later stage) was comparable to literature data, however, with significant inter-individual variations. The association of data of scintigraphy with L-DOPA test allows to improve sensitivity in 84% and specificity in 90.5%. Conclusion. - Our prospective study of 40 cases shows the relevance of cardiac sympathetic postganglionic imaging with I-123-mIBG coupled with myocardial perfusion scintigraphy to discriminate between MSA and PD with a higher sensitivity (71.4%) compared to the test with L-DOPA but a lower specificity (78.9%) than the L-DOPA. The difficulty of diagnosis is firstly linked to damage occurring to both the pre- and postganglionic sympathetic systems in patients with MSA and secondly to the integrity of the sympathetic nerve endings in patients with PD. However, the association of data of scintigraphy with L-DOPA test show a significant improvement of sensibility (84%). (C) 2010 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 49 条
[1]  
ADAM WMM, 2006, GRAYS ANATOMIC ETUDI, P185
[2]   How to use myocardial 123I-MIBG scintigraphy in chronic heart failure [J].
Agostini, Denis ;
Carrio, Ignasi ;
Verberne, Hein J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (04) :555-559
[3]   Profound cardiac sympathetic denervation occurs in Parkinson disease [J].
Amino, T ;
Orimo, S ;
Itoh, Y ;
Takahashi, A ;
Uchihara, T ;
Mizusawa, H .
BRAIN PATHOLOGY, 2005, 15 (01) :29-34
[4]   Parkinson's disease molecular imaging: Up-to-date [J].
Baulieu, J. -L. ;
Le-Pogam, A. ;
Leborgne, A. ;
Guilloteau, D. ;
Prunier-Aesch, C. .
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (04) :236-241
[5]   131I/123I-metaiodobenzylguanidine (MIBG) scintigraphy:: procedure guidelines for tumour imaging [J].
Bombardieri, E ;
Aktolun, C ;
Baum, RP ;
Bishof-Delaloye, A ;
Buscombe, J ;
Chatal, JF ;
Maffioli, L ;
Moncayo, R ;
Mortelmans, L ;
Reske, SN .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) :BP132-BP139
[6]   Cardiac uptake of [123I]MIBG separates Parkinson's disease from multiple system atrophy [J].
Braune, S ;
Reinhardt, M ;
Schnitzer, R ;
Riedel, A ;
Lücking, CH .
NEUROLOGY, 1999, 53 (05) :1020-1025
[7]   The role of cardiac metaiodobenzylguanidine uptake in the differential diagnosis of parkinsonian syndromes [J].
Braune, S .
CLINICAL AUTONOMIC RESEARCH, 2001, 11 (06) :351-355
[8]   Nuclear cardiologic study of Takotsubo cardiomyopathy [J].
Cimarelli, Sebastien ;
Imperiale, Alessio ;
Sauer, Frederique ;
Morel, Olivier ;
Ben Sellem, Dorra ;
Goetz, Christian ;
Blondet, Cyrille ;
Ohlmann, Patrick ;
Constantinesco, Andre .
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (02) :57-65
[9]  
COHEN A, 2002, COEUR MED INTERNE, P1821
[10]   Cardiac MIBG scintigraphy is a sensitive tool for detecting cardiac sympathetic denervation in Parkinson's disease [J].
Courbon, F ;
Brefel-Courbon, C ;
Thalamas, C ;
Alibelli, MJ ;
Berry, I ;
Montastruc, JL ;
Rascol, O ;
Senard, JM .
MOVEMENT DISORDERS, 2003, 18 (08) :890-897