Quality-by-Design Based Development and Validation of Stability Indicating Method by UPLC Method for Impurities of Simvastatin from Drug and Pharmaceutical Dosage Form

被引:1
作者
Desai, M. M. [1 ]
Nikalje, Ann Apratima G. [2 ]
机构
[1] Dr Babasaheb Ambedkar Marathwada Univ, Maulana Azad Coll Arts & Sci, Univ Campus, Aurangabad 431004, Maharashtra, India
[2] Wilson Coll, Mumbai 400007, Maharashtra, India
关键词
Simvastatin; ultra-performance liquid chromatography; quality-by-design; stress degradation; HPLC METHOD; EZETIMIBE;
D O I
10.36468/pharmaceutical-sciences.756
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A rapid, robust and accurate ultra-high performance liquid chromatographic method was developed and validated for determination of impurities of simvastatin in drug and its pharmaceutical formulation. A systematic Quality-by-design approach was used for method development with the Fusion AETM software, to screen and optimize the column, mobile phase, column temperature, gradient time and other chromatographic conditions. The optimized method uses Waters Acquity Charged Surface Hybrid, Octadecylsilane C18 (1.7 mu m x 2.1 mm x 100 mm) column with gradient elution. Orthophosphoric acid pH was adjusted to 4.5 with triethylamine and acetonitrile with a ratio of (80:20) was used as mobile phase A, whereas methanol:acetonitrile (20:80) as mobile phase B, with a flow rate of 0.35 ml/min. Ultra Violet detector was programmed at 238 nm with a runtime of 13 min, wherein all the impurities were well resolved and were separated from main peak of simvastatin. The method was validated for accuracy, repeatability, reproducibility and robustness. All the validation parameters were in acceptable range. The linearity, limit of detection and limit of quantitation was established for all the impurities and for simvastatin. The method was also applied suitably for determining the degradation products of simvastatin using stress degradation studies
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
[41]   Analytical quality-by-design approach for development and validation of HPLC method for the simultaneous estimation of omarigliptin, metformin, and ezetimibe: application to human plasma and dosage forms [J].
Galal Magdy ;
Amira A. Al-enna ;
Fathalla Belal ;
Ramadan A. El-Domany ;
Ahmed M. Abdel-Megied .
BMC Chemistry, 17
[42]   Quality by Design Based Method Development for Simultaneous Estimation of Montelukast Sodium and Theophylline in Tablet Dosage Form [J].
Shah, Kunti Abhishek ;
Parmar, Vijaykumar Kunvarji .
CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (06) :612-623
[43]   Development and Validation of Stability Indicating HPLC Method for Lamivudine, Zidovudine and Abacavir in Tablet Dosage Forms [J].
Reddiah, C. H. Venkata ;
Devi, P. Rama ;
Mukkanti, K. ;
Katari, Srinivasarao .
INTERNATIONAL JOURNAL OF PHARMACEUTICAL AND PHYTOPHARMACOLOGICAL RESEARCH, 2012, 1 (05) :247-256
[44]   Development and Optimization of Stability-Indicating Method of Solifenacin Succinate and its Main Product of Degradation in Tablet Dosage form using the Quality by Design Approach [J].
Raphael Cyriaco Cabral ;
Felipe Rebello Lourenço ;
Leandro Augusto Calixto .
Journal of Analytical Chemistry, 2023, 78 :S35-S45
[45]   Development and Optimization of Stability-Indicating Method of Solifenacin Succinate and its Main Product of Degradation in Tablet Dosage form using the Quality by Design Approach [J].
Cabral, Raphael Cyriaco ;
Lourenco, Felipe Rebello ;
Calixto, Leandro Augusto .
JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (SUPPL 1) :S35-S45
[46]   Stability Indicating LC Method Development for Hydroxychloroquine Sulfate Impurities as Available for Treatment of COVID-19 and Evaluation of Risk Assessment Prior to Method Validation by Quality by Design Approach [J].
Thirupathi Dongala ;
Naresh Kumar Katari ;
Ashok Kumar Palakurthi ;
Lakshmi Narasimha Rao Katakam ;
Vishnu Murthy Marisetti .
Chromatographia, 2020, 83 :1269-1281
[47]   Stability indicating RP-HPLC method development and validation for quantification of impurities in gonadotropin-releasing hormone (Elagolix): Robustness study by quality by design [J].
Bandaru, Lova Gani Raju ;
Kanuparthy, Phani Raja ;
Jeedimalla, Nagalakshmi ;
Nayak, Bhukya Vijay ;
Raghupathi, Jayaprakash Kanijam ;
Katari, Naresh Kumar ;
Gundla, Rambabu .
BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (12)
[48]   Stability Indicating LC Method Development for Hydroxychloroquine Sulfate Impurities as Available for Treatment of COVID-19 and Evaluation of Risk Assessment Prior to Method Validation by Quality by Design Approach [J].
Dongala, Thirupathi ;
Katari, Naresh Kumar ;
Palakurthi, Ashok Kumar ;
Katakam, Lakshmi Narasimha Rao ;
Marisetti, Vishnu Murthy .
CHROMATOGRAPHIA, 2020, 83 (10) :1269-1281
[49]   RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF NIACIN AND SIMVASTATIN IN TABLET DOSAGE FORM [J].
Mulagada, Gowri Manoja ;
Sridevi, S. ;
Devi, M. Gayathri ;
Kumar, Mukalla Ganesh .
INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (02) :1007-1012
[50]   Development and Validation of Stability-Indicating Assay Method by UPLC for a Fixed Dose Combination of Atorvastatin and Ezetimibe [J].
Goel, Amit ;
Baboota, Sanjula ;
Sahni, Jasjeet K. ;
Srinivas, Kona S. ;
Gupta, Ravi S. ;
Gupta, Abhishek ;
Semwal, Vinod P. ;
Ali, Javed .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2013, 51 (03) :222-228