Quality-by-Design Based Development and Validation of Stability Indicating Method by UPLC Method for Impurities of Simvastatin from Drug and Pharmaceutical Dosage Form

被引:0
作者
Desai, M. M. [1 ]
Nikalje, Ann Apratima G. [2 ]
机构
[1] Dr Babasaheb Ambedkar Marathwada Univ, Maulana Azad Coll Arts & Sci, Univ Campus, Aurangabad 431004, Maharashtra, India
[2] Wilson Coll, Mumbai 400007, Maharashtra, India
关键词
Simvastatin; ultra-performance liquid chromatography; quality-by-design; stress degradation; HPLC METHOD; EZETIMIBE;
D O I
10.36468/pharmaceutical-sciences.756
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A rapid, robust and accurate ultra-high performance liquid chromatographic method was developed and validated for determination of impurities of simvastatin in drug and its pharmaceutical formulation. A systematic Quality-by-design approach was used for method development with the Fusion AETM software, to screen and optimize the column, mobile phase, column temperature, gradient time and other chromatographic conditions. The optimized method uses Waters Acquity Charged Surface Hybrid, Octadecylsilane C18 (1.7 mu m x 2.1 mm x 100 mm) column with gradient elution. Orthophosphoric acid pH was adjusted to 4.5 with triethylamine and acetonitrile with a ratio of (80:20) was used as mobile phase A, whereas methanol:acetonitrile (20:80) as mobile phase B, with a flow rate of 0.35 ml/min. Ultra Violet detector was programmed at 238 nm with a runtime of 13 min, wherein all the impurities were well resolved and were separated from main peak of simvastatin. The method was validated for accuracy, repeatability, reproducibility and robustness. All the validation parameters were in acceptable range. The linearity, limit of detection and limit of quantitation was established for all the impurities and for simvastatin. The method was also applied suitably for determining the degradation products of simvastatin using stress degradation studies
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [21] Quality by design with design of experiments approach for development of a stability-indicating LC method for enzalutamide and its impurities in soft gel dosage formulation
    Katakam, Lakshmi Narasimha Rao
    Dongala, Thirupathi
    Ettaboina, Santhosh Kumar
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (05)
  • [22] Development and Validation of Stability Indicating UV-Visible Spectrophotometric Method for Simultaneous Estimation of Neem (Azadirachtin) and Curcumin in Pharmaceutical Tablet Dosage Form
    Sharma, Deepak
    Kaur, Parminderjit
    Singh, Gurmeet
    Singh, Davinder
    Verma, Shivani
    Singh, Jagjeet
    [J]. ANALYTICAL CHEMISTRY LETTERS, 2019, 9 (04) : 564 - 581
  • [23] Simultaneous Quantification of Related Substances of Ezetimibe and Simvastatin in Combined Dosage Form Using a Novel Stability-Indicating Liquid Chromatographic Method
    Desai, P. R.
    Mehta, P. J.
    Ojha, S. K.
    Chokshi, A. B.
    [J]. ACTA CHROMATOGRAPHICA, 2018, 30 (02) : 85 - 94
  • [24] Analytical quality-by-design approach for development and validation of HPLC method for the simultaneous estimation of omarigliptin, metformin, and ezetimibe: application to human plasma and dosage forms
    Magdy, Galal
    Al-enna, Amira A.
    Belal, Fathalla
    El-Domany, Ramadan A.
    Abdel-Megied, Ahmed M.
    [J]. BMC CHEMISTRY, 2023, 17 (01)
  • [25] Stability indicating HPTLC method development and validation of evogliptin in bulk and tablet dosage form by using a QbD approach
    Mahajan, M. P.
    Mahanwar, R. V.
    Gaikwad, S. S.
    Owal, R. M.
    [J]. ANALYTICAL CHEMISTRY LETTERS, 2024, 14 (04) : 561 - 578
  • [26] DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING REVERSED PHASE ULTRA PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE QUANTITATIVE ANALYSIS OF RALOXIFENE HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORM
    Saini, Deepa
    Baboota, Sanjula
    Ali, Mushir
    Patel, Harilal
    Jain, Pankaj
    Neerumulla, Sudhakar
    Ali, Javed
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 162 - 173
  • [27] Ultrafast Liquid Chromatographic Method Development and its Validation for Quantification of Telaprevir in Pharmaceutical Dosage Form by Using Quality by Design Approach
    Panda, Sagar Suman
    Bera, Venkata Varaha Ravi Kumar
    Beg, Sarwar
    Sahu, Sunil Kumar
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (07) : 1193 - 1202
  • [28] Stability-indicating RP-HPLC method development and validation for determination of nine impurities in apixaban tablet dosage forms. Robustness study by quality by design approach
    Subramanian, Velusamy B.
    Katari, Naresh Kumar
    Dongala, Thirupathi
    Jonnalagadda, Sreekantha B.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (01)
  • [29] STRESS DEGRADATION STUDIES OF DRONEDARONE IN PHARMACEUTICAL DOSAGE FORM BY A VALIDATED STABILITY-INDICATING LC METHOD
    Ahirrao, V. K.
    Patil, C. S.
    Bembalkar, S. R.
    Katariya, M. V.
    Sonnekar, V. S.
    Marathe, R. P.
    Nawale, R. B.
    Pawar, R. P.
    [J]. JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (03) : 1272 - 1276
  • [30] STABILITY INDICATING RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF PANTOPRAZOLE AND LEVOSULPIRIDE IN PHARMACEUTICAL DOSAGE FORM
    Shivaraju, Nivedeetha Halekote
    Kowmudi, Gullapalli
    Anoop, Karthika
    Nagappan, Krishnaveni
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2019, 10 (11): : 4949 - 4958