Contribution of high voltage direct current transmission systems to inter-area oscillation damping: A review

被引:38
作者
Vural, Ahmet Mete [1 ]
机构
[1] Gaziantep Univ, Elect & Elect Engn Dept, TR-27310 Sahinbey, Gaziantep, Turkey
关键词
High voltage direct current transmission; HVDC; Power system stability; Inter-area oscillation; Oscillation damping; HVDC damping controller; Renewable energy; MODULAR MULTILEVEL CONVERTERS; MULTIPLE FACTS CONTROLLERS; POWER-SYSTEM; VSC-HVDC; STABILITY ENHANCEMENT; WIND POWER; TIME-DELAY; INDUCTION GENERATORS; PRONY ANALYSIS; DESIGN;
D O I
10.1016/j.rser.2015.12.091
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The cumulative advancements on high voltage high current fully controlled semiconductor switching technology have led to positive progress for high voltage direct current (HVDC) systems for management and optimization of future power systems with large penetration of renewables in the form of distributed generation (DG). Inter-area oscillation is a natural power system phenomena that can be resulted from the oscillation of two distant groups of generators against each other with low or negative damping, causing to avoid maximum power transfer and system blackout at the worst case. Moreover, high penetration of DG can positively or negatively change the dynamic characteristics of power systems and affects system stability in terms of low frequency inter-area oscillations. Due to its flexibility and almost instant response, HVDC applications with a modified control scheme can offer a great advantage to transmission system control such as damping inter-area oscillations. This paper focuses on supplementary control strategies for damping inter-area oscillations with HVDC systems in the context of renewable DG penetration. First, detection methods for inter-area oscillations are summarized with a brief mathematical framework for each. Later on up-to-date HVDC transmission technology, including its development, converter topologies, operating configurations, and some recent HVDC projects are discussed from its preliminary historical development. HVDC converter modelling approaches and converter control techniques available in recent stability studies are also addressed. Finally, state of the art HVDC damping strategies are classified according to the way of generating damping signals with an emphasis on input signal selection, study system, and simulation tool. It is found that besides many simulation based validations for inter-area oscillation damping of HVDC systems, few practical application examples also exist, which are detailed to some extend paper by paper. Suggestions for future research directions are also incorporated. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:892 / 915
页数:24
相关论文
共 249 条
  • [1] Damping controller design for power system oscillations using global signals
    AboulEla, ME
    Sallam, AA
    McCalley, JD
    Fouad, AA
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1996, 11 (02) : 767 - 773
  • [2] Adams A, 2012, PROCEEDINGS OF THE 11TH EUROPEAN CONFERENCE ON INFORMATION WARFARE AND SECURITY, P1
  • [3] Optimization of Power System Stabilizers using BAT search algorithm
    Ali, E. S.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 61 : 683 - 690
  • [4] Full-adaptive THEN-part equipped fuzzy wavelet neural controller design of FACTS devices to suppress inter-area oscillations
    Alizadeh, Mojtaba
    Tofighi, Morteza
    [J]. NEUROCOMPUTING, 2013, 118 : 157 - 170
  • [5] New Transformerless, Scalable Modular Multilevel Converters for HVDC-Transmission
    Allebrod, Silke
    Hamerski, Roman
    Marquardt, Rainer
    [J]. 2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 174 - 179
  • [6] [Anonymous], 2015, BAIXAS SANTA LLOGAIA
  • [7] [Anonymous], 2012, PROC IEEE 10 IET INT
  • [8] [Anonymous], 2010, 1 ULTRAHIGH VOLTAGE
  • [9] [Anonymous], 2008, IEEE PES GEN M CONV
  • [10] [Anonymous], 2010, T BAY CABLE A BREAKT