Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton

被引:12
作者
Semrau, Jennifer A. [1 ,2 ,5 ]
Herter, Troy M. [3 ]
Scott, Stephen H. [4 ]
Dukelow, Sean P. [1 ,2 ]
机构
[1] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[2] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[3] Univ South Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[4] Queens Univ, Dept Anat & Cell Biol, Kingston, ON, Canada
[5] Foothills Med Ctr, South Tower Room 905,1403 29th St NW, Calgary, AB T2N 2T9, Canada
基金
加拿大健康研究院;
关键词
Proprioception; Kinesthesia; Stroke; Robotics; Sensorimotor; Inter-rater reliability; TEST-RETEST RELIABILITY; LIMB POSITION SENSE; MOTOR RECOVERY; STROKE; DEFICITS; IMPAIRMENT; CARE;
D O I
10.1186/s12984-017-0260-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (similar to 60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Methods: Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 +/- 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. Results: We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). Conclusions: The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying kinesthesia after stroke.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Inter-rater reliability of the radiographic assessment of simple bone cysts
    Cho, S.
    Yankanah, R.
    Babyn, P.
    Stimec, J.
    Doria, A. S.
    Stephens, D.
    Wright, J. G.
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2019, 13 (02) : 226 - 235
  • [42] Inter-rater reliability of the Illinois Structured Decision Support Protocol
    Kang, HA
    Poertner, J
    CHILD ABUSE & NEGLECT, 2006, 30 (06) : 679 - 689
  • [43] Inter-rater reliability and validity of peer reviews in an interdisciplinary field
    Jens Jirschitzka
    Aileen Oeberst
    Richard Göllner
    Ulrike Cress
    Scientometrics, 2017, 113 : 1059 - 1092
  • [44] Inter-rater reliability of ICD-10 in Chinese patients
    Pang, AHT
    Ungvari, GS
    Wong, CK
    Leung, T
    EUROPEAN PSYCHIATRY, 1997, 12 (01) : 8 - 10
  • [45] Inter-rater and intra-rater reliability of nursing process records for patients with schizophrenia
    Chung, Min-Huey
    Chiang, I-Jen
    Chou, Kuei-Ru
    Chu, Hsin
    Chang, Hsiu-Ju
    JOURNAL OF CLINICAL NURSING, 2010, 19 (21-22) : 3023 - 3030
  • [46] Intra-rater and inter-rater reliability of six musculoskeletal preparticipatory screening tests
    Zumana, Nosipho
    Olivier, Benita
    Godlwana, Lonwabo
    Martin, Candice
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2019, 75 (01)
  • [47] Inter-rater Reliability of Preceptors on Clinical Pharmacy Competency Evaluation
    Thomas, Dixon
    Khalifa, Sherief
    Sreedharan, Jayadevan
    Bond, Rucha
    CURRENT DRUG THERAPY, 2021, 16 (02) : 148 - 153
  • [48] Inter-rater reliability of the French version of the core index for melancholia
    Thuile, J
    Even, C
    Friedman, S
    Guelfi, JD
    JOURNAL OF AFFECTIVE DISORDERS, 2005, 88 (02) : 193 - 208
  • [49] Inter-rater reliability of the Chedoke Arm and Hand Activity Inventory
    Johnson, Denise
    Harris, Jocelyn
    Stratford, Paul
    Richardson, Julie
    NEUROREHABILITATION, 2017, 40 (02) : 201 - 209
  • [50] Inter-rater reliability of the simplified Modified Rankin Scale as an outcome measure for treated cerebral aneurysm patients
    Bacchus, E.
    Kate, M. P.
    Benomar, A.
    Farzin, B.
    Raymond, J.
    Darsaut, T. E.