Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton

被引:12
|
作者
Semrau, Jennifer A. [1 ,2 ,5 ]
Herter, Troy M. [3 ]
Scott, Stephen H. [4 ]
Dukelow, Sean P. [1 ,2 ]
机构
[1] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[2] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[3] Univ South Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[4] Queens Univ, Dept Anat & Cell Biol, Kingston, ON, Canada
[5] Foothills Med Ctr, South Tower Room 905,1403 29th St NW, Calgary, AB T2N 2T9, Canada
基金
加拿大健康研究院;
关键词
Proprioception; Kinesthesia; Stroke; Robotics; Sensorimotor; Inter-rater reliability; TEST-RETEST RELIABILITY; LIMB POSITION SENSE; MOTOR RECOVERY; STROKE; DEFICITS; IMPAIRMENT; CARE;
D O I
10.1186/s12984-017-0260-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (similar to 60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Methods: Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 +/- 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. Results: We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). Conclusions: The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying kinesthesia after stroke.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Inter-rater reliability of the Play Assessment for Group Settings
    Lautamo, Tiina
    Heikkila, Maija
    SCANDINAVIAN JOURNAL OF OCCUPATIONAL THERAPY, 2011, 18 (01) : 3 - 10
  • [22] The inter-rater reliability of the Pulmonary Embolism Severity Index
    Fraga, Montserrat
    Taffe, Patrick
    Mean, Marie
    Hugli, Olivier
    Witzig, Stephanie
    Waeber, Gerard
    Aujesky, Drahomir
    THROMBOSIS AND HAEMOSTASIS, 2010, 104 (06) : 1258 - 1262
  • [23] Inter-rater reliability of a national acute stroke register
    Varmdal T.
    Ellekjær H.
    Fjærtoft H.
    Indredavik B.
    Lydersen S.
    Bonaa K.H.
    BMC Research Notes, 8 (1)
  • [24] Inter-rater reliability of the Conversational Assessment of Neurocognitive Dysfunction
    Oba, Hikaru
    Hiyama, Masami
    Okamoto, Haruka
    Onoda, Rika
    Matsuoka, Teruyuki
    Sato, Shinichi
    Narumoto, Jin
    PSYCHOGERIATRICS, 2023, 23 (04) : 667 - 674
  • [25] Inter-Rater Reliability for Thrombolysis in Cerebral Infarction with TICI 2c Category
    Volny, Ondrej
    Cimflova, Petra
    Szeder, Viktor
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (05): : 992 - 994
  • [26] Inter-rater reliability of trunk muscle morphometric analysis
    Valentin, Stephanie
    Yeates, Tobey DeMott
    Licka, Theresia
    Elliott, James
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2015, 28 (01) : 181 - 190
  • [27] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [28] Inter-Rater Reliability of Kampo Diagnosis for Chronic Diseases
    Maeda-Minami, Ayako
    Yoshino, Tetsuhiro
    Horiba, Yuko
    Nakamura, Tomonori
    Watanabe, Kenji
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2021, 27 (07) : 613 - 616
  • [29] Inter-rater reliability of the Modified Modified Ashworth Scale as a clinical tool in measurements of post-stroke elbow flexor spasticity
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Mousakhani, Atefeh
    Nouriyan, Azam
    Omidvar, Zeinab
    NEUROREHABILITATION, 2009, 24 (03) : 225 - 229
  • [30] The inter-rater reliability of the Turkish version of Aphasia Rapid Test for stroke
    Kavakci, Mariam
    Koyuncu, Engin
    Tanriverdi, Melike
    Adiguzel, Emre
    Yasar, Evren
    TOPICS IN STROKE REHABILITATION, 2022, 29 (04) : 272 - 279