Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton

被引:12
|
作者
Semrau, Jennifer A. [1 ,2 ,5 ]
Herter, Troy M. [3 ]
Scott, Stephen H. [4 ]
Dukelow, Sean P. [1 ,2 ]
机构
[1] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[2] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[3] Univ South Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[4] Queens Univ, Dept Anat & Cell Biol, Kingston, ON, Canada
[5] Foothills Med Ctr, South Tower Room 905,1403 29th St NW, Calgary, AB T2N 2T9, Canada
基金
加拿大健康研究院;
关键词
Proprioception; Kinesthesia; Stroke; Robotics; Sensorimotor; Inter-rater reliability; TEST-RETEST RELIABILITY; LIMB POSITION SENSE; MOTOR RECOVERY; STROKE; DEFICITS; IMPAIRMENT; CARE;
D O I
10.1186/s12984-017-0260-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (similar to 60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Methods: Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 +/- 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. Results: We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). Conclusions: The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying kinesthesia after stroke.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton
    Jennifer A. Semrau
    Troy M. Herter
    Stephen H. Scott
    Sean P. Dukelow
    Journal of NeuroEngineering and Rehabilitation, 14
  • [2] Testing the Reliability of Inter-Rater Reliability
    Eagan, Brendan
    Brohinsky, Jais
    Wang, Jingyi
    Shaffer, David Williamson
    LAK20: THE TENTH INTERNATIONAL CONFERENCE ON LEARNING ANALYTICS & KNOWLEDGE, 2020, : 454 - 461
  • [3] Inter-rater reliability of shoulder measurements in middle-aged women
    De Groef, A.
    Van Kampen, M.
    Vervloesem, N.
    Clabau, E.
    Christiaens, M-R.
    Neven, P.
    Geraerts, I.
    Struyf, F.
    Devoogdt, N.
    PHYSIOTHERAPY, 2017, 103 (02) : 222 - 230
  • [4] Movement kinematics and proprioception in post-stroke spasticity: assessment using the Kinarm robotic exoskeleton
    Mochizuki, George
    Centen, Andrew
    Resnick, Myles
    Lowrey, Catherine
    Dukelow, Sean P.
    Scott, Stephen H.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (01)
  • [5] The inter-rater reliability of shoulder arthroscopy
    Sasyniuk, Treny M.
    Mohtadi, Nicholas G. H.
    Hollinshead, Robert M.
    Russell, Margaret L.
    Fick, Gordon H.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (09): : 971 - 977
  • [6] Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
    Sin, Minki
    Kim, Won-Seok
    Cho, Kyujin
    Paik, Nam-Jong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (148):
  • [7] Inter-rater reliability of delirium rating scales
    Bhat, R
    Rockwood, K
    NEUROEPIDEMIOLOGY, 2005, 25 (01) : 48 - 52
  • [8] On inter-Rater reliability of information security experts
    Shoufan, Abdulhadi
    Damiani, Ernesto
    JOURNAL OF INFORMATION SECURITY AND APPLICATIONS, 2017, 37 : 101 - 111
  • [9] The inter-rater reliability of mental capacity assessments
    Raymont, Vanessa
    Buchanan, Alec
    David, Anthony S.
    Hayward, Peter
    Wessely, Simon
    Hotopf, Matthew
    INTERNATIONAL JOURNAL OF LAW AND PSYCHIATRY, 2007, 30 (02) : 112 - 117
  • [10] Cheiloscopy: Lip Print Inter-rater Reliability
    Furnari, Winnie
    Janal, Malvin N.
    JOURNAL OF FORENSIC SCIENCES, 2017, 62 (03) : 782 - 785