Comparison of 4 methods for quantifying posterior capsule opacification

被引:114
作者
Findl, O
Buehl, W
Menapace, R
Georgopoulos, M
Rainer, G
Siegl, H
Kaider, A
Pinz, A
机构
[1] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Univ Vienna, Sect Clin Biometr, Dept Med Comp Sci, A-1090 Vienna, Austria
[3] Graz Tech Univ, Inst Elect Measurement & Measurement Signal Proc, Graz, Austria
基金
奥地利科学基金会;
关键词
D O I
10.1016/S0886-3350(02)01509-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the results of posterior capsule opacification (PCO) quantification and the repeatability of a fully automated analysis system (Automated Quantification of After-Cataract [AQUA]) with that of 2 other quantification methods and subjective grading of PCO. A test set of digital retroillumination images of 100 eyes with PCO of varying degrees was used. Setting. Department of Ophthalmology, University of Vienna, Vienna, Austria. Methods: One hundred digital retroillumination images of eyes (100 patients) with PCO were selected to attain an even distribution from mild to severe cases. The images were evaluated by 4 methods: subjective grading by 4 experienced and 4 inexperienced examiners, the subjective Evaluation of Posterior Capsular Opacification (EPCO) system, posterior capsule opacification (POCO) software, and the AQUA system. Ten images were presented twice to assess the reproducibility of the analysis systems. Results. Subjective grading correlated best with the subjective EPCO system and the objective AQUA system (r = 0.94 and r = 0.93, respectively). The POCO system showed very early saturation and therefore a much weaker correlation (r = 0.73). The POCO scores reached the maximum of 100% in several minimal to mild PCO cases. The reproducibility of the AQUA software was perfect and that of the other analysis systems, comparably satisfactory. Conclusion: The objective AQUA score correlated well with subjective methods including the EPCO system. The POCO system, which assesses PCO area, did not adequately describe PCO intensity and includes a subjective step in the analysis process. The AQUA system could become an important tool for randomized masked trials of PCO inhibition. (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 9 条
  • [1] Barman SA, 2000, INVEST OPHTH VIS SCI, V41, P3882
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification
    Buehl, W
    Findl, O
    Menapace, R
    Georgopoulos, M
    Rainer, G
    Wirtitsch, M
    Siegl, H
    Pinz, A
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) : 265 - 270
  • [4] The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    Hollick, EJ
    Spalton, DJ
    Ursell, PG
    Pande, MV
    Barman, SA
    Boyce, JF
    Tilling, K
    [J]. OPHTHALMOLOGY, 1999, 106 (01) : 49 - 54
  • [5] High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery
    Pande, MV
    Ursell, PG
    Spalton, DJ
    Heath, G
    Kundaiker, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (10) : 1521 - 1527
  • [6] A systematic overview of the incidence of posterior capsule opacification
    Schaumberg, DA
    Dana, MR
    Christen, WG
    Glynn, RJ
    [J]. OPHTHALMOLOGY, 1998, 105 (07) : 1213 - 1221
  • [7] Posterior capsule opacification - Part 2: Clinical findings
    Tetz, MR
    Nimsgern, C
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (12) : 1662 - 1674
  • [8] Photographic image analysis system of posterior capsule opacification
    Tetz, MR
    Auffarth, GU
    Sperker, M
    Blum, M
    Volcker, HE
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (10) : 1515 - 1520
  • [9] Relationship between intraocular lens biomaterials and posterior capsule opacification
    Ursell, PG
    Spalton, DJ
    Pande, MV
    Hollick, EJ
    Barman, S
    Boyce, J
    Tilling, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03) : 352 - 360