Impact of an abbreviated adenosine protocol incorporating adjunctive treadmill exercise on adverse effects and image duality in patients undergoing stress myocardial perfusion imaging

被引:39
作者
Elliott, MD [1 ]
Holly, TA [1 ]
Leonard, SM [1 ]
Hendel, RC [1 ]
机构
[1] Northwestern Univ, Sch Med, Dept Med, Div Cardiol, Chicago, IL 60611 USA
关键词
adenosine; radioisotopes; stress testing; single photon emission computed tomography;
D O I
10.1067/mnc.2000.108737
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Limited data are available about the effects of adjunctive treadmill exercise on adverse effects and the image quality of adenosine perfusion imaging. This study compared the incidence of adverse effects and image quality between standard 6-minute adenosine perfusion imaging and a stress test incorporating a 4-minute adenosine infusion with low-level treadmill exercise. Methods and Results. Nineteen patients underwent both a 6-minute adenosine technetium-99m sestamibi single photon emission computed tomography (SPECT) imaging study and a 4-minute adenosine Tc-99m sestamibi SPECT study with 6 minutes of simultaneous low-level treadmill exercise. Symptoms were recorded at 1-minute intervals during the stress and recovery periods. Heart-to-liver and heart-to-lung count ratios were determined from anterior planar images. More adverse effects were experienced during the standard adenosine study than during the adenosine study with low-level exercise (2.7 +/- 1.4 vs 1.4 +/0 1.1, P =.0003). The duration adverse effects were experienced was longer during the standard 6-minute adenosine protocol (6.6 +/- 2.1 minutes vs 3.2 +/- 2.8 minutes, P <.0001). Additionally, the symptom-severity scores were higher with the standard adenosine study (15.5 +/- 9.8 vs 4.5 +/- 5.1, P <.0001). The heart-to-liver ratios were noted to be higher in the 4-minute adenosine protocol with low-level exercise (1.0 +/- 0.3 vs 0.6 +/- 0.2, P =.0003). Conclusions. In comparison with standard 6-minute adenosine perfusion imaging, a protocol incorporating a 4-minute adenosine infusion with low-level treadmill exercise results in a marked reduction in the quantity and severity of adverse effects and an improvement in image quality.
引用
收藏
页码:584 / 589
页数:6
相关论文
共 13 条
  • [1] SIMULTANEOUS LOW-LEVEL TREADMILL EXERCISE AND INTRAVENOUS DIPYRIDAMOLE STRESS THALLIUM IMAGING
    CASALE, PN
    GUINEY, TE
    STRAUSS, HW
    BOUCHER, CA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (10) : 799 - 802
  • [2] SAFETY PROFILE OF ADENOSINE STRESS PERFUSION IMAGING - RESULTS FROM THE ADENOSCAN-MULTICENTER-TRIAL-REGISTRY
    CERQUEIRA, MD
    VERANI, MS
    SCHWAIGER, M
    HEO, J
    ISKANDRIAN, AS
    ALAZRAKI, NP
    BEAN, LC
    BELARDINELLI, L
    BELL, M
    BERMAN, DS
    BOTVINICK, EH
    CHEIRIF, J
    HANSEN, CL
    HELLER, GV
    JOHNSTON, DL
    LEPPO, JA
    MADDAHI, J
    PARKER, LS
    MOHIUDDIN, S
    RAICHLEN, JS
    REIS, GJ
    SCHELBERT, HR
    SEALS, AA
    STOLZENBERG, J
    WILLIAMS, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) : 384 - 389
  • [3] Comparison of adenosine and high-dose dipyridamole both combined with low-level exercise stress for Tc-99(m)-MIBI SPET myocardial perfusion imaging
    Cramer, MJM
    Verzijlbergen, JF
    VanderWall, EE
    Vermeersch, PH
    Niemeyer, MG
    Zwinderman, AH
    Ascoop, CA
    Pauwels, EKJ
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (02) : 97 - 104
  • [4] IGNASZEWSKI AP, 1993, J NUCL MED, V34, P2053
  • [5] Impact of limited treadmill exercise on adenosine Tc-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging in coronary artery disease
    Jamil, G
    Ahlberg, AW
    Elliott, MD
    Hendel, RC
    Holly, T
    McGill, CC
    Sarkis, M
    White, MP
    Mather, JF
    Waters, DD
    Heller, GV
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (04) : 400 - 403
  • [6] TL-201 MYOCARDIAL PERFUSION SPET - ADENOSINE ALONE OR COMBINED WITH DYNAMIC EXERCISE
    MAHMOOD, S
    GUPTA, NK
    GUNNING, M
    BOMANJI, JB
    JARRITT, PH
    ELL, PJ
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (08) : 586 - 592
  • [7] 4-MINUTE VERSUS 8-MINUTE INFUSION PROTOCOL FOR ADENOSINE TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGING
    OKEEFE, JH
    BATEMAN, TM
    HANDLIN, LR
    BARNHART, CS
    [J]. AMERICAN HEART JOURNAL, 1995, 129 (03) : 482 - 487
  • [8] PENNELL DJ, 1994, J NUCL MED, V35, P425
  • [9] ADENOSINE COMBINED WITH DYNAMIC EXERCISE FOR MYOCARDIAL PERFUSION IMAGING
    PENNELL, DJ
    MAVROGENI, SI
    FORBAT, SM
    KARWATOWSKI, SP
    UNDERWOOD, SR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (06) : 1300 - 1309
  • [10] Adenosine myocardial SPECT for detection of coronary artery disease: A comparison of 3 and 6 minute protocols
    Reyes, GA
    He, ZX
    Cwajg, E
    Treuth, MG
    Mahmarian, JJ
    Verani, MS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 518A - 519A