EPR study of radiation stability of organic plastic scintillator for cardiovascular brachytherapy Sr90-Y90 beta dosimetry

被引:7
作者
Alcón, EPQ [1 ]
Lopes, RT
de Almeida, CEV
机构
[1] Univ Estado Rio De Janeiro, Lab Ciencias Radiol, Rio De Janeiro, Brazil
[2] UFRJ, LIN, PEN, COPPE, Rio De Janeiro, Brazil
关键词
EPR; organic plastic scintillator; intravascular brachytherapy; dosimetry; Monte Carlo;
D O I
10.1016/j.apradiso.2004.08.035
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Nowadays, more than one million percutaneous transluminal coronary angioplasties are being performed annually throughout the world. Restenosis is a significant problem associated with these angioplasty procedures. Radiation treatment with catheter-based beta-emitter sources is currently under clinical trial to prevent this problem. Due to fast and worldwide introduction of beta-sources for intravascular application, there is a growing interest in the dosimetry aspects. However, accurate dosimetry of beta-radiation is more difficult than that of gamma-radiation. Suitable detectors are not yet available with accuracy down to a tenth of, a millimeter. Conventional measuring systems are not capable of such spatial resolution, except radiochromic film. However, film dosimeters have limited sensitivity and their radiation characteristics are different than those of tissue; therefore dose measurements require corrections. An alternative is to use water-equivalent plastic scintillators. In this work, organic plastic scintillator (BCF-10) dosimetry is studied using the Monte Carlo (MC) technique PENELOPE, and its radiation stability, after irradiation, is experimentally studied through electron paramagnetic resonance (EPR). Depth dose and dose profile are measured and compared to film dosimetry results. The EPR technique shows that the recovery time is dose independent in this kind of fiber and shows good stability. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:301 / 306
页数:6
相关论文
共 17 条
[1]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[2]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[3]   Plastic scintillation dosimetry: optimization of light collection efficiency [J].
Beddar, AS ;
Law, S ;
Suchowerska, N ;
Mackie, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (09) :1141-1152
[4]   New approaches to preventing restenosis [J].
Bhargava, B ;
Karthikeyan, G ;
Abizaid, AS ;
Mehran, R .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7409) :274-279
[5]   A GENERAL THEORY OF CAVITY IONISATION [J].
BURLIN, TE .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (466) :727-&
[6]  
Fluhs D, 1996, MED PHYS, V23, P427, DOI 10.1118/1.597736
[7]   Intravascular brachytherapy of the coronary arteries [J].
Fox, RA .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (04) :R1-R30
[8]   EFFY - A NEW PROGRAM TO COMPUTE THE COUNTING EFFICIENCY OF BETA-PARTICLES IN LIQUID SCINTILLATORS [J].
GARCIATORANO, E ;
MALONDA, AG .
COMPUTER PHYSICS COMMUNICATIONS, 1985, 36 (03) :307-312
[9]  
GELLMAN J, 1991, CIRCULATION, V84, pA46
[10]   ABC of interventional cardiology - New developments in percutaneous coronary intervention [J].
Gunn, J ;
Grech, ED ;
Crossman, D ;
Cumberland, D .
BRITISH MEDICAL JOURNAL, 2003, 327 (7407) :150-153