A Nordic survey of patient doses in diagnostic radiology

被引:11
作者
Gron, P
Olerud, HM
Einarsson, G
Leitz, W
Servomaa, A
Schoultz, BW
Hjardenmaal, O
机构
[1] Natl Inst Radiat Hyg, DK-2730 Herlev, Denmark
[2] Norwegian Radiat Protect Author, N-1332 Osteras, Norway
[3] Icelandic Radiat Protect Inst, IS-150 Reykjavik, Iceland
[4] Swedish Radiat Protect Inst, S-17116 Stockholm, Sweden
[5] STUK Radiat & Nucl Safety Author, Helsinki 00881, Finland
关键词
diagnostic radiology; patient doses; reference values; kerma-area product;
D O I
10.1007/s003300000535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to test the applicability of the guidance levels for patient doses cooperatively set by the radiation protection authorities in : five Nordic countries. The kerma-area product (KAP) for five conventional radiological examination types was obtained from several hospitals in each of the Nordic countries. The number of radiographic images and fluoroscopy time were also registered, and the mean values for each examination pe and hospital were established based on a representative number of patients (40-100 kg). The results indicate that the situation is very similar in the five Nordic countries, even though some differences ere identified. Most of the hospitals demonstrated lower doses than the proposed guidance levels for lest, probably explained by use of faster film/screen combinations during the past decade. An increased use of fluoroscopy for positioning was observed for radiographic examinations of lumbar spine and urography Large variations in patient doses were found,for barium enema depending on the use of fluorospot or 100-mm camera vs full-format film, the range in fluoroscopy times, dose rate, and field size. The guidance levels, pelvis (4 cm(2)), urography (20 Gy x cm(2)), and barium en150 (Gy x cm(2)) seem to reflect the present quality X-ray equipment and examination techniques in five Nordic countries. The guidance levels for chest (1 Gy x cm(2)) should be lowered to 0.6 Gy x cm(2).
引用
收藏
页码:1988 / 1992
页数:7
相关论文
共 6 条
[1]  
CARMICHAEL JHE, 1996, 16260 OFF OFF PUBL E
[2]  
HART D, 1996, NRPBR289
[3]  
International Commission on Radiological Protection, 1991, ICRP PUBL
[4]   Diagnostic radiology in Norway from 1983 to 1993 - Examination frequency and collective effective dose to patients [J].
Olerud, HM ;
Saxebol, G .
RADIATION PROTECTION DOSIMETRY, 1997, 74 (04) :247-260
[5]   Nordic guidance levels for patient doses in diagnostic radiology [J].
Saxebol, G ;
Olerud, HM ;
Hjardemaal, O ;
Leitz, W ;
Servomaa, A ;
Walderhaug, T .
RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) :99-101
[6]  
SAXEBOL G, 1990, RAD CANC RISK, P139