AUTOMATIC NEUTRON DOSIMETRY SYSTEM BASED ON FLUORESCENT NUCLEAR TRACK DETECTOR TECHNOLOGY

被引:25
作者
Akselrod, M. S. [1 ]
Fomenko, V. V. [1 ]
Bartz, J. A. [1 ,2 ]
Haslett, T. L. [3 ]
机构
[1] Landauer Inc, Stillwater, OK 74074 USA
[2] Oklahoma State Univ, Stillwater, OK 74078 USA
[3] Avo Photon Inc, Horsham, PA 19044 USA
关键词
AL2O3-C; MG CRYSTALS;
D O I
10.1093/rpd/nct293
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For the first time, the authors are describing an automatic fluorescent nuclear track detector (FNTD) reader for neutron dosimetry. FNTD is a luminescent integrating type of detector made of aluminium oxide crystals that does not require electronics or batteries during irradiation. Non-destructive optical readout of the detector is performed using a confocal laser scanning fluorescence imaging with near-diffraction limited resolution. The fully automatic table-top reader allows one to load up to 216 detectors on a tray, read their engraved IDs using a CCD camera and optical character recognition, scan and process simultaneously two types of images in fluorescent and reflected laser light contrast to eliminate false-positive tracks related to surface and volume crystal imperfections. The FNTD dosimetry system allows one to measure neutron doses from 0.1 mSv to 20 Sv and covers neutron energies from thermal to 20 MeV. The reader is characterised by a robust, compact optical design, fast data processing electronics and user-friendly software.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 15 条
[1]   Fluorescent nuclear track detector technology - A new way to do passive solid state dosimetry [J].
Akselrod, M. S. ;
Sykora, G. J. .
RADIATION MEASUREMENTS, 2011, 46 (12) :1671-1679
[2]   New Al2O3:C,Mg crystals for radiophotoluminescent dosimetry and optical imaging [J].
Akselrod, Mark S. ;
Akselrod, Anna E. .
RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) :218-221
[3]  
[Anonymous], 2013, ISO219091 1
[4]  
[Anonymous], 2009, N13112009 ANSI
[5]   Evaluation of aluminum oxide fluorescent and OSL detectors in proton radiotherapy beams [J].
Bartz, J. A. ;
Sykora, G. J. ;
Underwood, T. H. ;
Nichiporov, D. N. ;
Sawakuchi, G. O. ;
Akselrod, M. S. .
RADIATION MEASUREMENTS, 2011, 46 (12) :1974-1978
[6]   PROTON-RECOIL NEUTRON DOSIMETER FOR PERSONNEL MONITORING [J].
BENTON, EV ;
OSWALD, RA ;
FRANK, AL ;
WHEELER, RV .
HEALTH PHYSICS, 1981, 40 (06) :801-809
[8]   Anisotropy of optical absorption and fluorescence in Al2O3:C,Mg crystals -: art. no. 033518 [J].
Sanyal, S ;
Akselrod, MS .
JOURNAL OF APPLIED PHYSICS, 2005, 98 (03)
[9]   Properties of novel fluorescent nuclear track detectors for use in passive neutron dosimetry [J].
Sykora, G. J. ;
Salasky, M. ;
Akselrod, M. S. .
RADIATION MEASUREMENTS, 2008, 43 (2-6) :1017-1023
[10]   Spectroscopic properties of novel fluorescent nuclear track detectors for high and low LET charged particles [J].
Sykora, G. J. ;
Akselrod, M. S. ;
Benton, E. R. ;
Yasuda, N. .