Flat detector C-arm CT-guided transthoracic needle biopsy of small (aparts per thousandcurrency sign2.0 cm) pulmonary nodules: diagnostic accuracy and complication in 100 patients

被引:15
作者
Jiao, Dechao [1 ]
Yuan, Huifeng [1 ]
Zhang, Quanhui [1 ]
Han, Xinwei [1 ]
机构
[1] Zhengzhou Univ, Dept Intervent Radiol, Affiliated Hosp 1, Zhengzhou 450052, Henan, Peoples R China
来源
RADIOLOGIA MEDICA | 2016年 / 121卷 / 04期
关键词
Interventional; Biopsy; Lung; Computer applications-3D; ASPIRATION BIOPSY; INITIAL-EXPERIENCE; LUNG; LESIONS; GUIDANCE; SYSTEM;
D O I
10.1007/s11547-015-0604-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed at assessing the usefulness of flat detector cone-beam CT virtual navigation-guided transthoracic needle biopsy of small (a parts per thousand currency sign2.0 cm) pulmonary nodules in terms of diagnostic accuracy and complications to evaluate the diagnostic performance and complications of small pulmonary nodules under cone-beam CT (CBCT) guidance. A total of 100 patients with 100 solid lung nodules were retrospectively enrolled to undergo transthoracic needle biopsy (TNB) procedures. The mean diameter of lesions was 1.25 cm +/- A 0.39 (range 0.50-2.00 cm). The needle path was carefully planned and calculated on the CBCT virtual navigation guidance system, which acquired 3D CT-like cross-sectional images. Diagnostic performance, complication rate, and patient radiation exposure were investigated. The technical success rate of TNB under iGuide CBCT virtual navigation system was 99 % (99/100). The sensitivity, specificity, and accuracy of TNB of small nodules under iGuide CBCT virtual navigation guidance were 98.7 % (77/78), 90.5 % (19/21), and 97.0 % (96/99), respectively. The number of pleural passages with coaxial needle, biopsies, and CBCT acquisitions were 1.09 +/- A 0.32, 1.20 +/- A 0.47, and 3.06 +/- A 1.35, respectively. Complications occurred in 22 (22 %) cases. The mean total procedure time was 12.84 min +/- A 3.74, resulting in a mean exposure dose of 7.6 mSv +/- 3.1. Flat detector Cone-beam CT-guided TNB is a highly accurate and safe diagnostic method for small (a parts per thousand currency sign2.0 cm) lung nodule.
引用
收藏
页码:268 / 278
页数:11
相关论文
共 28 条
[11]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[12]   CT Fluoroscopy-Guided Biopsy of 1,000 Pulmonary Lesions Performed With 20-Gauge Coaxial Cutting Needles: Diagnostic Yield and Risk Factors for Diagnostic Failure [J].
Hiraki, Takao ;
Mimura, Hidefumi ;
Gobara, Hideo ;
Iguchi, Toshihiro ;
Fujiwara, Hiroyasu ;
Sakurai, Jun ;
Matsui, Yusuke ;
Inoue, Daisaku ;
Toyooka, Shinichi ;
Sano, Yoshifumi ;
Kanazawa, Susumu .
CHEST, 2009, 136 (06) :1612-1617
[13]   C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules [J].
Hwang, Hye Sun ;
Chung, Myung Jin ;
Lee, Ju Won ;
Shin, Sung Wook ;
Lee, Kyung Soo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :W400-W407
[14]   Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions [J].
Jiao, De-Chao ;
Li, Teng-Fei ;
Han, Xin-Wei ;
Wu, Gang ;
Ma, Ji ;
Fu, Ming-Ti ;
Sun, Qi ;
Beilner, Janina .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (06) :470-474
[15]   Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems [J].
Jin, Kwang Nam ;
Park, Chang Min ;
Goo, Jin Mo ;
Lee, Hyun Ju ;
Lee, Youkyung ;
Kim, Jung Im ;
Choi, So Young ;
Kim, Hyo-Cheol .
EUROPEAN RADIOLOGY, 2010, 20 (09) :2108-2115
[16]   Flat-detector computed tomography (FD-CT) [J].
Kalender, Willi A. ;
Kyriakou, Yiannis .
EUROPEAN RADIOLOGY, 2007, 17 (11) :2767-2779
[17]   CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance [J].
Kim, Ga Ram ;
Hur, Jin ;
Lee, Sang Min ;
Lee, Hye-Jeong ;
Hong, Yoo Jin ;
Nam, Ji Eun ;
Kim, Hua Sun ;
Kim, Young Jin ;
Choi, Byoung Wook ;
Kim, Tae Hoon ;
Choe, Kyu Ok .
EUROPEAN RADIOLOGY, 2011, 21 (02) :232-239
[18]   CT fluoroscopy-assisted puncture of thoracic and abdominal masses: A randomized trial [J].
Kirchner, J ;
Kickuth, R ;
Laufer, U ;
Schilling, EM ;
Adams, S ;
Liermann, D .
CLINICAL RADIOLOGY, 2002, 57 (03) :188-192
[19]   C- Arm Cone-Beam CT-guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules: Clinical Experience in 1108 Patients [J].
Lee, Sang Min ;
Park, Chang Min ;
Lee, Kyung Hee ;
Bahn, Young Eun ;
Kim, Jung Im ;
Goo, Jin Mo .
RADIOLOGY, 2014, 271 (01) :291-300
[20]   Effective doses in radiology and diagnostic nuclear medicine: A catalog [J].
Mettler, Fred A., Jr. ;
Huda, Walter ;
Yoshizumi, Terry T. ;
Mahesh, Mahadevappa .
RADIOLOGY, 2008, 248 (01) :254-263