Flat detector C-arm CT-guided transthoracic needle biopsy of small (aparts per thousandcurrency sign2.0 cm) pulmonary nodules: diagnostic accuracy and complication in 100 patients

被引:15
作者
Jiao, Dechao [1 ]
Yuan, Huifeng [1 ]
Zhang, Quanhui [1 ]
Han, Xinwei [1 ]
机构
[1] Zhengzhou Univ, Dept Intervent Radiol, Affiliated Hosp 1, Zhengzhou 450052, Henan, Peoples R China
来源
RADIOLOGIA MEDICA | 2016年 / 121卷 / 04期
关键词
Interventional; Biopsy; Lung; Computer applications-3D; ASPIRATION BIOPSY; INITIAL-EXPERIENCE; LUNG; LESIONS; GUIDANCE; SYSTEM;
D O I
10.1007/s11547-015-0604-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed at assessing the usefulness of flat detector cone-beam CT virtual navigation-guided transthoracic needle biopsy of small (a parts per thousand currency sign2.0 cm) pulmonary nodules in terms of diagnostic accuracy and complications to evaluate the diagnostic performance and complications of small pulmonary nodules under cone-beam CT (CBCT) guidance. A total of 100 patients with 100 solid lung nodules were retrospectively enrolled to undergo transthoracic needle biopsy (TNB) procedures. The mean diameter of lesions was 1.25 cm +/- A 0.39 (range 0.50-2.00 cm). The needle path was carefully planned and calculated on the CBCT virtual navigation guidance system, which acquired 3D CT-like cross-sectional images. Diagnostic performance, complication rate, and patient radiation exposure were investigated. The technical success rate of TNB under iGuide CBCT virtual navigation system was 99 % (99/100). The sensitivity, specificity, and accuracy of TNB of small nodules under iGuide CBCT virtual navigation guidance were 98.7 % (77/78), 90.5 % (19/21), and 97.0 % (96/99), respectively. The number of pleural passages with coaxial needle, biopsies, and CBCT acquisitions were 1.09 +/- A 0.32, 1.20 +/- A 0.47, and 3.06 +/- A 1.35, respectively. Complications occurred in 22 (22 %) cases. The mean total procedure time was 12.84 min +/- A 3.74, resulting in a mean exposure dose of 7.6 mSv +/- 3.1. Flat detector Cone-beam CT-guided TNB is a highly accurate and safe diagnostic method for small (a parts per thousand currency sign2.0 cm) lung nodule.
引用
收藏
页码:268 / 278
页数:11
相关论文
共 28 条
[1]  
Bissoli Ernesto, 2003, Radiol Med, V106, P201
[2]   Effective Dose during Needle Interventions: Cone-beam CT Guidance Compared with Conventional CT Guidance [J].
Braak, Sicco J. ;
van Strijen, Marco J. L. ;
van Es, Hendrik W. ;
Nievelstein, Rutger A. J. ;
van Heesewijk, Johannes P. M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (04) :455-461
[3]  
Braak SJ, 2003, AM J ROENTGENOL, V194, P445
[4]   CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: A prospective randomized controlled clinical trial [J].
Carlson, SK ;
Felmlee, JP ;
Bender, CE ;
Ehman, RL ;
Classic, KL ;
Hoskin, TL ;
Harmsen, WS ;
Hu, HH .
RADIOLOGY, 2005, 237 (02) :701-708
[5]   Initial experience with percutaneous biopsies of bone lesions using XperGuide cone-beam CT (CBCT): technical note [J].
Carrafiello, G. ;
Fontana, F. ;
Mangini, M. ;
Ierardi, A. M. ;
Cotta, E. ;
Floridi, C. ;
Piacentino, F. ;
Fugazzola, C. .
RADIOLOGIA MEDICA, 2012, 117 (08) :1386-1397
[6]   Percutaneous transthoracic needle biopsy of small (aparts per thousandcurrency sign1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance [J].
Choo, Ji Yung ;
Park, Chang Min ;
Lee, Nyoung Keun ;
Lee, Sang Min ;
Lee, Hyun-Ju ;
Goo, Jin Mo .
EUROPEAN RADIOLOGY, 2013, 23 (03) :712-719
[7]   Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: Initial results [J].
El-Sheik, M ;
Heverhagen, JT ;
Alfke, H ;
Froelich, JJ ;
Hornegger, J ;
Brunner, T ;
Klose, KJ ;
Wagner, HJ .
RADIOLOGY, 2001, 221 (03) :843-849
[8]   C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules [J].
Floridi, Chiara ;
Muollo, Alessandra ;
Fontana, Federico ;
Rotolo, Nicola ;
Ierardi, Anna Maria ;
Duka, Ejona ;
Pellegrino, Carlo ;
Carrafiello, Gianpaolo .
RADIOLOGIA MEDICA, 2014, 119 (11) :820-827
[9]   CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[10]   Flat-Panel Volume CT: Fundamental Principles, Technology, and Applications [J].
Gupta, Rajiv ;
Cheung, Arnold C. ;
Bartling, Soenke H. ;
Lisauskas, Jennifer ;
Grasruck, Michael ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Brady, Thomas J. .
RADIOGRAPHICS, 2008, 28 (07) :2009-2022