Determination of fetogram plutonium by extraction chromatography using isotope dilution inductively coupled plasma mass spectrometry

被引:0
作者
Jin, YR [1 ]
Zhang, LZ
Han, SJ
Zhu, FR
Bai, JF
Zhou, GQ
Ma, F
Zhang, LX
机构
[1] Zhejiang Univ, Dept Chem, Hangzhou 310027, Peoples R China
[2] NW Inst Nucl Technol, Xian 710024, Peoples R China
关键词
ICP-MS; plutonium; tri-n-octylamine; extraction chromatography; detection limit;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work reports the determination of fetogram plutonium using isotope dilution ICP - MS. The interference of protonated uranium at m/z of 239, with a determined UH+/U+ ratio of 4.6 x 10(-5), was removed by using tri-n-octylamine extraction chromatography. The separation factor of 10(4) was achieved for uranium and the recovery of plutonium was greater than 75%. By applying isotope dilution, fetogram range of plutonium was measured using a high - resolution ICP - MS with a sample volume of less than 1mL. The limit of detection of Pu-239 is 4.5 x 10(-15) g/mL for standard solution, and 16.3 x 10(-15) g/mL for real sample with matrix. The concentration of Pu-239 in region atmosphere was determined at a level of (4.8 +/- 2.9) x 10(-17) g/m(3).
引用
收藏
页码:1291 / 1295
页数:5
相关论文
共 10 条
[1]  
Becker J.S., 1998, ADV MASS SPECTROM, V14, P687
[2]   Development of a high-sensitivity inductively coupled plasma mass spectrometer for actinide measurement in the femtogram range [J].
Chiappini, R ;
Taillade, JM ;
Brebion, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :497-503
[3]   Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisation [J].
Eroglu, AE ;
McLeod, CW ;
Leonard, KS ;
McCubbin, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1221-1233
[4]  
FABRIZIOSENA IGA, 1995, J ANAL ATOM SPECTROM, V10, P381
[5]  
Farmer OT, 1995, AM SOC TEST MATER, V1291, P38, DOI 10.1520/STP15978S
[6]   Applications of thermal ionization mass spectrometry to the detection of 239Pu and 240Pu intakes [J].
Inkret, WC ;
Efurd, DW ;
Miller, G ;
Rokop, DJ ;
Benjamin, TM .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 178 (1-2) :113-120
[7]  
JIN Q, 1977, ANAL ULTRAOURANIUM E, P13
[8]  
JIN Y, 1999, P 3 ENV RAD S XIAN, P148
[9]   High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples [J].
Stürup, S ;
Dahlgaard, H ;
Nielsen, SC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) :1321-1326
[10]  
8703