Improving the accuracy of tibial component placement during total knee replacement in varus knees with tibial bowing: A prospective randomised controlled study

被引:7
作者
Palanisami, Dhanasekararaja [1 ]
Jagdishbhai, Chirag Parsana [1 ]
Manohar, Mithun [1 ]
Ramesh, Pradeep [1 ]
Natesan, Rajkumar [1 ]
Shanmuganathan, Rajasekaran [1 ]
机构
[1] Ganga Hosp, Dept Orthopaed Surg, Coimbatore, Tamil Nadu, India
关键词
Extramedullary tibial jig; Limb alignment; Tibial bowing; Tibial component placement; Total knee arthroplasty; Varus knee; ALIGNMENT; ARTHROPLASTY; JAPANESE; SURFACE; LIMB; CUT;
D O I
10.1016/j.knee.2019.05.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Lateral tibial bowing leads to varus placement of the tibial component during total knee replacement in varus knees. Lateralised tibial jig placement can improve the accuracy of the tibial cut. Methods: A total of 227 patients (300 knees) undergoing total knee replacements were randomised into two groups. In the study group, the point of intersection of the distal tibial diaphyseal line at the tibial plateau drawn on long films was represented by zones. Knees with femoral bowing >5 degrees (28%) were excluded. Tibial jig placement on the 'proximal tibia was lateralised according to the zones. In the control group, the mid-point of the tibial plateau was taken as a reference. Femoral and tibial bowing, postoperative limb alignment and component placement were assessed. Results: Of the 216 knees that were studied, 106 were in the study group and 110 in the control group. Bowing >= 3 degrees had a significant positive correlation with lateralisation of the proximal tibial reference (p < 0.001). The Incidence of tibial bowing >= 3 degrees was 5733%. The mean postoperative hip-knee-ankle (HKA) angle was 178.31 +/- 2.88 degrees and 176.53 +/- 2.88 degrees (p < 0.001), whereas the mean medial proximal tibial angle (MPTA) was 89.91 +/- 1.42 degrees and 88.79 +/- 1.72 degrees (p < 0.001) in the study and control groups, respectively. Considering bowed tibiae alone, HKA angle and MPTA in the study group were 178.08 +/- 2.81 degrees and 89.72 +/- 139 degrees compared with 175.88 +/- 2.87 degrees and 88.38 +/- 138 degrees in the control group (p < 0.001). Conclusion: There is a high incidence of tibial bowing in varus knees. Lateralised tibial jig placement improved tibial component placement and postoperative limb alignment in total knee arthroplasty in varus knees with tibial bowing. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:1088 / 1095
页数:8
相关论文
共 50 条
  • [31] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Sahin, Namik
    Atici, Teoman
    Ozturk, Alpaslan
    Ozkaya, Guven
    Ozkan, Yuksel
    Avcu, Bulent
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 565 - 570
  • [32] Methods of intra- and post-operative determination of the position of the tibial component during total knee replacement
    Roman Popescu
    Emil G. Haritinian
    Stefan Cristea
    International Orthopaedics, 2020, 44 : 119 - 128
  • [33] Can Achilles tendon be used as a new distal landmark for coronal tibial component alignment in total knee replacement surgery? An observational MRI study
    Tiftikci, Ugur
    Serbest, Sancar
    Burulday, Veysel
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2017, 13 : 81 - 86
  • [34] The effectiveness of reinfusion after total knee replacement. A prospective randomised controlled study
    A. Zacharopoulos
    A. Apostolopoulos
    A. Kyriakidis
    International Orthopaedics, 2007, 31 : 303 - 308
  • [35] Investigation of the control of rotational alignment in the tibial component during total knee arthroplasty
    Hanada, Mitsuru
    Furuhashi, Hiroki
    Matsuyama, Yukihiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (06) : 1313 - 1317
  • [36] Investigation of the control of rotational alignment in the tibial component during total knee arthroplasty
    Mitsuru Hanada
    Hiroki Furuhashi
    Yukihiro Matsuyama
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1313 - 1317
  • [37] Improving Tibial Component Coronal Alignment During Total Knee Arthroplasty with the Use of a Double-Check Technique
    Ma, De-Si
    Wang, Zhi-Wei
    Wen, Liang
    Ren, Shi-Xiang
    Lin, Yuan
    Zhang, Bo
    ORTHOPAEDIC SURGERY, 2019, 11 (06) : 1013 - 1019
  • [38] Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle–trochlear groove can be an aid
    He Zhang
    Chengming Cao
    Han Zhang
    Shoujiang Han
    Journal of Orthopaedic Surgery and Research, 17
  • [39] Varus placement of the tibial component reduces the potential risk of fracture with adequate bony coverage in the Oxford unicompartmental knee arthroplasty
    Kamenaga, Tomoyuki
    Hiranaka, Takafumi
    Suda, Yoshihito
    Fujishiro, Takaaki
    Okamoto, Koji
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [40] The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty (TKA)
    Drexler, Michael
    Backstein, David
    Studler, Ueli
    Lakstein, Dror
    Haviv, Barak
    Schwarzkopf, Ran
    Rutenberg, Tal Frenkel
    Warschawski, Yaniv
    Rath, Ehud
    Kosashvili, Yona
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) : 1736 - 1742