Improving the accuracy of tibial component placement during total knee replacement in varus knees with tibial bowing: A prospective randomised controlled study

被引:7
作者
Palanisami, Dhanasekararaja [1 ]
Jagdishbhai, Chirag Parsana [1 ]
Manohar, Mithun [1 ]
Ramesh, Pradeep [1 ]
Natesan, Rajkumar [1 ]
Shanmuganathan, Rajasekaran [1 ]
机构
[1] Ganga Hosp, Dept Orthopaed Surg, Coimbatore, Tamil Nadu, India
关键词
Extramedullary tibial jig; Limb alignment; Tibial bowing; Tibial component placement; Total knee arthroplasty; Varus knee; ALIGNMENT; ARTHROPLASTY; JAPANESE; SURFACE; LIMB; CUT;
D O I
10.1016/j.knee.2019.05.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Lateral tibial bowing leads to varus placement of the tibial component during total knee replacement in varus knees. Lateralised tibial jig placement can improve the accuracy of the tibial cut. Methods: A total of 227 patients (300 knees) undergoing total knee replacements were randomised into two groups. In the study group, the point of intersection of the distal tibial diaphyseal line at the tibial plateau drawn on long films was represented by zones. Knees with femoral bowing >5 degrees (28%) were excluded. Tibial jig placement on the 'proximal tibia was lateralised according to the zones. In the control group, the mid-point of the tibial plateau was taken as a reference. Femoral and tibial bowing, postoperative limb alignment and component placement were assessed. Results: Of the 216 knees that were studied, 106 were in the study group and 110 in the control group. Bowing >= 3 degrees had a significant positive correlation with lateralisation of the proximal tibial reference (p < 0.001). The Incidence of tibial bowing >= 3 degrees was 5733%. The mean postoperative hip-knee-ankle (HKA) angle was 178.31 +/- 2.88 degrees and 176.53 +/- 2.88 degrees (p < 0.001), whereas the mean medial proximal tibial angle (MPTA) was 89.91 +/- 1.42 degrees and 88.79 +/- 1.72 degrees (p < 0.001) in the study and control groups, respectively. Considering bowed tibiae alone, HKA angle and MPTA in the study group were 178.08 +/- 2.81 degrees and 89.72 +/- 139 degrees compared with 175.88 +/- 2.87 degrees and 88.38 +/- 138 degrees in the control group (p < 0.001). Conclusion: There is a high incidence of tibial bowing in varus knees. Lateralised tibial jig placement improved tibial component placement and postoperative limb alignment in total knee arthroplasty in varus knees with tibial bowing. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:1088 / 1095
页数:8
相关论文
共 50 条
  • [21] Individualised distal femoral cut improves femoral component placement and limb alignment during total knee replacement in knees with moderate and severe varus deformity
    Dhanasekararaja Palanisami
    Geethan Iyyampillai
    Sivaraj Shanmugam
    Rajkumar Natesan
    Rajasekaran S
    International Orthopaedics, 2016, 40 : 2049 - 2054
  • [22] Tibial Component Alignment After Total Knee Arthroplasty with Intramedullary Instrumentation: A Prospective Analysis
    Talmo, Carl T.
    Cooper, Andrew J.
    Wuerz, Tom
    Lang, Jason E.
    Bono, James V.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08) : 1209 - 1215
  • [23] Internal rotational error of the tibial component is a major cause of pain after total knee replacement
    Nicoll, D.
    Rowley, D. I.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (09): : 1238 - 1244
  • [24] Accuracy of tibial positioning in the frontal plane: a prospective study comparing conventional and innovative techniques in total knee arthroplasty
    Zahn, R. K.
    Graef, F.
    Conrad, J. L.
    Renner, L.
    Perka, C.
    Hommel, H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (06) : 793 - 800
  • [25] Relationship between the Femoral and Tibial Component Positions and Postoperative Knee Range of Motion after Posterior-Stabilized Total Knee Arthroplasty in Varus-Aligned Knees
    Hanada, Mitsuru
    Hotta, Kensuke
    Koyama, Hiroshi
    Matsuyama, Yukihiro
    JOURNAL OF KNEE SURGERY, 2023, 36 (12) : 1302 - 1307
  • [26] Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study
    Yoshitomo Saiki
    Tomohiro Ojima
    Tamon Kabata
    Seigaku Hayashi
    Hiroyuki Tsuchiya
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 2267 - 2276
  • [27] Using a Tibial Short Extension Stem Reduces Tibial Component Loosening After Primary Total Knee Arthroplasty in Severely Varus Knees: Long-term Survival Analysis With Propensity Score Matching
    Park, Min-ho
    Bin, Seong-Il
    Kim, Jong-Min
    Lee, Bum-Sik
    Lee, Chang-Rack
    Kwon, Young-Hee
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08) : 2512 - 2517
  • [28] The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation
    Jazrawi, LM
    Birdzell, L
    Kummer, FJ
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 2000, 15 (06) : 761 - 766
  • [29] Current review of surgical management options for rotational alignment of the femoral and tibial component in total knee replacement
    Cretu, Bogdan
    Cirstoiu, Catalin
    Cristea, Stefan
    ROMANIAN JOURNAL OF MILITARY MEDICINE, 2019, 122 (02) : 16 - 20
  • [30] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Namık Şahin
    Teoman Atıcı
    Alpaslan Öztürk
    Güven Özkaya
    Yüksel Özkan
    Bülent Avcu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 565 - 570