摘要
Background: Lateral tibial bowing leads to varus placement of the tibial component during total knee replacement in varus knees. Lateralised tibial jig placement can improve the accuracy of the tibial cut. Methods: A total of 227 patients (300 knees) undergoing total knee replacements were randomised into two groups. In the study group, the point of intersection of the distal tibial diaphyseal line at the tibial plateau drawn on long films was represented by zones. Knees with femoral bowing >5 degrees (28%) were excluded. Tibial jig placement on the 'proximal tibia was lateralised according to the zones. In the control group, the mid-point of the tibial plateau was taken as a reference. Femoral and tibial bowing, postoperative limb alignment and component placement were assessed. Results: Of the 216 knees that were studied, 106 were in the study group and 110 in the control group. Bowing >= 3 degrees had a significant positive correlation with lateralisation of the proximal tibial reference (p < 0.001). The Incidence of tibial bowing >= 3 degrees was 5733%. The mean postoperative hip-knee-ankle (HKA) angle was 178.31 +/- 2.88 degrees and 176.53 +/- 2.88 degrees (p < 0.001), whereas the mean medial proximal tibial angle (MPTA) was 89.91 +/- 1.42 degrees and 88.79 +/- 1.72 degrees (p < 0.001) in the study and control groups, respectively. Considering bowed tibiae alone, HKA angle and MPTA in the study group were 178.08 +/- 2.81 degrees and 89.72 +/- 139 degrees compared with 175.88 +/- 2.87 degrees and 88.38 +/- 138 degrees in the control group (p < 0.001). Conclusion: There is a high incidence of tibial bowing in varus knees. Lateralised tibial jig placement improved tibial component placement and postoperative limb alignment in total knee arthroplasty in varus knees with tibial bowing. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:1088 / 1095
页数:8
相关论文
共 50 条
  • [11] Individualised distal femoral cut improves femoral component placement and limb alignment during total knee replacement in knees with moderate and severe varus deformity
    Palanisami, Dhanasekararaja
    Iyyampillai, Geethan
    Shanmugam, Sivaraj
    Natesan, Rajkumar
    Rajasekaran, S.
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (10) : 2049 - 2054
  • [12] Surgical Navigation Improves the Precision and Accuracy of Tibial Component Alignment in Canine Total Knee Replacement
    Peters, Kaleigh M.
    Hutter, Erin
    Siston, Robert A.
    Bertran, Judith
    Allen, Matthew J.
    VETERINARY SURGERY, 2016, 45 (01) : 52 - 59
  • [13] The effect of the posterior slope of the tibial plateau osteotomy with a rotational error on tibial component malalignment in total knee replacement
    Tsukeoka, T.
    Tsuneizumi, Y.
    Lee, T. H.
    BONE & JOINT JOURNAL, 2013, 95B (09) : 1201 - 1203
  • [14] The influence of tibial component malalignment on bone strain in revision total knee replacement
    Rastetter, Benjamin R.
    Wright, Samantha J.
    Gheduzzi, Sabina
    Miles, Anthony W.
    Clift, Sally E.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (06) : 561 - 568
  • [15] Specific tibial landmarks to improve to accuracy of the tibial cut during total knee arthroplasty. A case control study
    Parratte, Sebastien
    Azmi, Zakee
    Daxelet, Jeremy
    Argenson, Jean-Noel
    Batailler, Cecile
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4101 - 4108
  • [16] Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study
    Saiki, Yoshitomo
    Ojima, Tomohiro
    Kabata, Tamon
    Hayashi, Seigaku
    Tsuchiya, Hiroyuki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2267 - 2276
  • [17] Tibial component overhang in total knee replacement: Incidence and functional outcomes
    McArthur, John
    Makrides, Panos
    Thangarajah, Thanujan
    Brooks, Stuart
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (02): : 199 - 202
  • [18] Tibial component in total knee replacement : the effect of overhang and sizing on outcome
    Foubert, Knud
    Heylen, Steven
    Plaeke, Philip
    Somville, Johan
    Nicolai, Paul
    ACTA ORTHOPAEDICA BELGICA, 2017, 83 (04): : 659 - 663
  • [19] Lateral subvastus approach with osteotomy of the tibial tubercle for total knee replacement A TWO-YEAR PROSPECTIVE, RANDOMISED, BLINDED CONTROLLED TRIAL
    Hay, G. C.
    Kampshoff, J.
    Kuster, M. S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (06): : 862 - 866
  • [20] Tibial shaft axis does not always serve as a correct coronal landmark in total knee arthroplasty for varus knees
    Matsuda, S
    Mizu-uchi, H
    Miura, H
    Nagamine, R
    Urabe, K
    Iwamoto, Y
    JOURNAL OF ARTHROPLASTY, 2003, 18 (01) : 56 - 62