Can low-dose computed tomographic scan of the spine replace conventional radiography? An evaluation based on imaging myelomas, bone metastases, and fractures from osteoporosis

被引:23
作者
Chassang, Madleen [1 ]
Grimaud, Anne [1 ]
Cucchi, J. M. [1 ]
Novellas, Sebastien [1 ]
Amoretti, Nicolas [1 ]
Chevallier, Patrick [1 ]
Bruneton, Jean Noeel [1 ]
机构
[1] Hop Archet 2, Serv Imagerie Diag & Intervent, F-06200 Nice 3, France
关键词
CT low dose; spine; myeloma; bone metastases; osteoporosis;
D O I
10.1016/j.clinimag.2007.04.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated and compared the radiological images of the spine of 111 patients affected by myeloma, bone metastases, and fractures secondary to osteoporosis demonstrated in low-dose computed tomographic (CT) scans and those demonstrated in conventional radiographic studies. From the analysis of the data obtained, it appears that the duration of the CT procedure is definitely shorter and that its diagnostic sensitivity is superior to that of conventional radiography. We should mention that the dose of radiation delivered by CT scanning does not constitute an unfavorable element in patients, usually elderly, for whom CT scanning was indicated. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:225 / 227
页数:3
相关论文
共 8 条
  • [1] Spiral computed tomography for the initial evaluation of spine trauma: A new standard of care?
    Antevil, Jared L.
    Sise, Michael J.
    Sack, Daniel I.
    Kidder, Brendan
    Hopper, Andrew
    Brown, Carlos V. R.
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (02): : 382 - 387
  • [2] Whole-body CT screening: Spectrum of findings and recommendations in 1192 patients
    Furtado, CD
    Aguirre, DA
    Sirlin, CB
    Dang, D
    Stamato, SK
    Lee, P
    Sani, F
    Brown, MA
    Levin, DL
    Casola, G
    [J]. RADIOLOGY, 2005, 237 (02) : 385 - 394
  • [3] Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography
    Horger, M
    Claussen, CD
    Bross-Bach, U
    Vonthein, R
    Trabold, T
    Heuschmid, M
    Pfannenberg, C
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (02) : 289 - 297
  • [4] Multidetector CT of the spine in multiple myeloma:: Comparison with MR imaging and radiography.
    Mahnken, AH
    Wildberger, JE
    Gehbauer, G
    Schmitz-Rode, T
    Blaum, M
    Fabry, U
    Günther, RW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (06) : 1429 - 1436
  • [5] Obaid AK, 2006, AM SURGEON, V72, P951
  • [6] Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: Initial experience
    Ptak, T
    Rhea, JT
    Novelline, RA
    [J]. RADIOLOGY, 2003, 229 (03) : 902 - 905
  • [7] Scutellari P N, 2000, Radiol Med, V100, P429
  • [8] Scutellari P N, 1992, Radiol Med, V83, P542