A two-stage rotary blood pump design with potentially lower blood trauma: a computational study

被引:28
|
作者
Thamsen, Bente [1 ]
Mevert, Ricardo [1 ]
Lommel, Michael [1 ]
Preikschat, Philip [1 ]
Gaebler, Julia [1 ]
Krabatsch, Thomas [2 ]
Kertzscher, Ulrich [1 ]
Hennig, Ewald [2 ]
Affeld, Klaus [1 ]
机构
[1] Charite, Biofluid Mech Lab, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Deutsch Herzzentrum Berlin, Dept Cardiothorac & Vasc Surg, Berlin, Germany
来源
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS | 2016年 / 39卷 / 04期
关键词
Blood trauma; Computational fluid dynamics; Rotary blood pump; Two-stage pump; VENTRICULAR ASSIST DEVICES; SHEAR-STRESS; HEARTMATE II; DAMAGE; THROMBOSIS;
D O I
10.5301/ijao.5000482
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aim: In current rotary blood pumps, complications related to blood trauma due to shear stresses are still frequently observed clinically. Reducing the rotor tip speed might decrease blood trauma. Therefore, the aim of this project was to design a two-stage rotary blood pump leading to lower shear stresses. Methods: Using the principles of centrifugal pumps, two diagonal rotor stages were designed with an outer diameter of 22 mm. The first stage begins with a flow straightener and terminates with a diffusor, while a volute casing behind the second stage is utilized to guide fluid to the outlet. Both stages are combined into one rotating part which is pivoted by cup-socket ruby bearings. Details of the flow field were analyzed employing computational fluid dynamics (CFD). A functional model of the pump was fabricated and the pressure-flow dependency was experimentally assessed. Results: Measured pressure-flow performance of the developed pump indicated its ability to generate adequate pressure heads and flows with characteristic curves similar to centrifugal pumps. According to the CFD results, a pressure of 70 mmHg was produced at a flow rate of 5 L/min and a rotational speed of 3200 rpm. Circumferential velocities could be reduced to 3.7 m/s as compared to 6.2 m/s in a clinically used axial rotary blood pump. Flow fields were smooth with well-distributed pressure fields and comparatively few recirculation or vortices. Substantially smaller volumes were exposed to high shear stresses > 150 Pa. Conclusions: Hence, blood trauma might be reduced with this design. Based on these encouraging results, future in vitro investigations to investigate actual blood damage are intended.
引用
收藏
页码:178 / 183
页数:6
相关论文
共 44 条
  • [31] Impact of gap size and groove design of hydrodynamic bearing on plasma skimming effect for use in rotary blood pump
    Jiang, Ming
    Sakota, Daisuke
    Kosaka, Ryo
    Hijikata, Wataru
    JOURNAL OF ARTIFICIAL ORGANS, 2022, 25 (03) : 195 - 203
  • [32] Impact of gap size and groove design of hydrodynamic bearing on plasma skimming effect for use in rotary blood pump
    Ming Jiang
    Daisuke Sakota
    Ryo Kosaka
    Wataru Hijikata
    Journal of Artificial Organs, 2022, 25 : 195 - 203
  • [33] Structural improvement study of streamline design method, conical hub, and auxiliary blades for axial blood pump
    Yu, Zheqin
    Tan, Jianping
    Wang, Shuai
    Guo, Bin
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (04): : 251 - 261
  • [34] Effect of Continuous Arterial Blood Flow of Intra-aorta Pump on the Aorta - A computational study
    Xuan, Yanjiao
    Chang, Yu
    Gao, Bin
    Gu, Kaiyun
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 672 - 676
  • [35] Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump
    Anderson, JB
    Wood, HG
    Allaire, PE
    Bearnson, G
    Khanwilkar, P
    ARTIFICIAL ORGANS, 2000, 24 (05) : 377 - 385
  • [36] Experimental study on thermal performance of two-stage ejector heat pump heating system with large temperature drop
    Lin, Jiyou
    Wu, Ronghua
    Yu, Hao
    Zhou, Jiashuo
    Zhang, Chenghu
    ENERGY AND BUILDINGS, 2024, 324
  • [37] Effects on the pulmonary hemodynamics and gas exchange with a speed modulated right ventricular assist rotary blood pump: a numerical study
    Huang, Feng
    Gou, Zhe
    Fu, Yang
    Ruan, Xiaodong
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [38] Effects on the pulmonary hemodynamics and gas exchange with a speed modulated right ventricular assist rotary blood pump: a numerical study
    Feng Huang
    Zhe Gou
    Yang Fu
    Xiaodong Ruan
    BioMedical Engineering OnLine, 17
  • [39] A comparative study between flow visualization and computational fluid dynamic analysis for the Sun Medical centrifugal blood pump
    Yamane, T
    Miyamoto, T
    Tajima, T
    Yamazaki, K
    ARTIFICIAL ORGANS, 2004, 28 (05) : 458 - 466
  • [40] Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study
    Nakata, K
    Yosikawa, M
    Takano, T
    Sankai, Y
    Ohtsuka, G
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    ARTIFICIAL ORGANS, 2000, 24 (04) : 315 - 319