Skull fracture prediction through subject-specific finite element modelling is highly sensitive to model parameters

被引:11
作者
De Kegel, Dries [1 ]
Meynen, Alexander [2 ]
Famaey, Nele [1 ]
van Lenthe, G. Harry [1 ]
Depreitere, Bart [3 ]
Vander Sloten, Jos [1 ]
机构
[1] Katholieke Univ Leuven, Biomech Sect, Leuven, Belgium
[2] Katholieke Univ Leuven, Inst Orthopaed Res & Training, Dept Dev & Regenerat, Fac Med, Leuven, Belgium
[3] Katholieke Univ Leuven, Dept Neurosurg, Univ Hosp Gasthuisberg, Leuven, Belgium
关键词
Finite element modelling; Head injury; Impact biomechanics; Skull fracture; HUMAN HEAD; MECHANICAL-PROPERTIES; VALIDATION; BIOMECHANICS; INJURY; TISSUE; BONE;
D O I
10.1016/j.jmbbm.2019.103384
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reliable computer models are needed for a better understanding of the physical mechanisms of skull fracture in accidental hits, falls, bicycle - motor vehicle & car accidents and assaults. The performance and biofidelity of these models depend on the correct anatomical representation and material description of these structures. In literature, a strain energy criterion has been proposed to predict skull fractures. However, a broad range of values for this criterion has been reported. This study investigates if the impactor orientation, scalp thickness and material model of the skull could provide us with insight in the influencing factors of this criterion. 18 skull fracture experiments previously performed in our research group were reproduced in finite element simulations. Subject-specific skull geometries were derived from medical images and used to create high-quality finite element meshes. Based on local Hounsfield units, a subject-specific isotropic material model was assigned. The subject-specific models were able to predict fractures who matched visually with the corresponding experimental fracture patterns and provided detailed fracture patterns. The sensitivity study showed that small variations in impactor positioning as well as variations of the local geometry (frontal-temporal-occipital) strongly influenced the skull strain energy. Subject-specific modelling leads to a more accurate prediction of the force-displacement curve. The average error of the peak fracture force for all the 18 cases is 0.4190 for the subject-specific and 0.4538 for the homogeneous material model, for the displacement; 0.3368 versus 0.3844. But it should be carefully interpreted as small variations in the computational model significantly influence the outcome.
引用
收藏
页数:12
相关论文
共 60 条
[41]   The Importance of the Scalp in Head Impact Kinematics [J].
Trotta, Antonia ;
Zouzias, Dimitris ;
De Bruyne, Guido ;
Ni Annaidh, Aisling .
ANNALS OF BIOMEDICAL ENGINEERING, 2018, 46 (06) :831-840
[42]   Development and validation of two subject-specific finite element models of human head against three cadaveric experiments [J].
Tse, Kwong Ming ;
Tan, Long Bin ;
Lee, Shu Jin ;
Lim, Siak Piang ;
Lee, Heow Pueh .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2014, 30 (03) :397-415
[43]  
Vander Vorst Michael, 2003, Annu Proc Assoc Adv Automot Med, V47, P363
[44]  
Vander Vorst Michael, 2004, Annu Proc Assoc Adv Automot Med, V48, P181
[45]   A new test set-up for skull fracture characterisation [J].
Verschueren, P. ;
Delye, H. ;
Depreitere, B. ;
Van Lierde, C. ;
Haex, B. ;
Berckmans, D. ;
Verpoest, I. ;
Goffin, J. ;
Sloten, J. Vander ;
Van der Perre, G. .
JOURNAL OF BIOMECHANICS, 2007, 40 (15) :3389-3396
[46]   Deriving tissue density and elastic modulus from microCT bone scans [J].
Wagner, David W. ;
Lindsey, Derek P. ;
Beaupre, Gary S. .
BONE, 2011, 49 (05) :931-938
[47]  
Willinger R., 2000, Int J Crashworthiness, V5, P249
[48]   BIOMECHANICS OF SKULL FRACTURE [J].
YOGANANDAN, N ;
PINTAR, FA ;
SANCES, A ;
WALSH, PR ;
EWING, CL ;
THOMAS, DJ ;
SNYDER, RG .
JOURNAL OF NEUROTRAUMA, 1995, 12 (04) :659-668
[49]  
Zhan Y., 2012, FRONT NEUROENERGETIC, V4, P1
[50]  
[No title captured]