A new hybrid anti-islanding algorithm in grid connected three-phase inverter system

被引:0
|
作者
Yin, Jun [1 ]
Chang, Liuchen [1 ]
Diduch, Chris [1 ]
机构
[1] Univ New Brunswick, Dept Elect & Comp Engn, POB 4400, Fredericton, NB E3B 5A3, Canada
来源
2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7 | 2006年
关键词
anti-islanding; covariance; distributed generation; inverter; non-detection zone;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Passive and active methods are two major categories of anti-islanding approaches which are being widely used in grid-connected distributed generation (DG) systems. Passive anti-islanding techniques have no negative impact on the inverter's performance however large non-detection zone is the shortcoming of these techniques. On the other hand, active approaches have smaller non-detection zone, but these active approaches inevitably have negative impact on inverter's performance. To solve these problems, a new hybrid of both passive and active anti-islanding algorithm is proposed in this paper. A covariance index is used as a passive indicator to activate an active anti-islanding action, adaptive reactive power shift action, which can intelligently vary the output reactive power of the DG system to realize the anti-islanding protections. Both simulation and experimental results have demonstrated that this new algorithm can provide a fast anti-islanding protection while assure the zero or the least perturbation in inverter's grid-connected operation.
引用
收藏
页码:367 / +
页数:2
相关论文
共 50 条
  • [1] Anti-Islanding for Three-Phase One-Cycle Control Grid Tied Inverter
    Tedde, Marco
    Smedley, Keyue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (07) : 3330 - 3345
  • [2] Implementation of Anti-islanding Scheme for a Grid Connected Inverter
    Saikia, Arup Kumar
    Kapil, P. N.
    POWER ELECTRONICS AND RENEWABLE ENERGY SYSTEMS, 2015, 326 : 213 - 223
  • [3] Passive anti-Islanding protection for Three-Phase Grid-Connected photovoltaic power systems
    Banu, Ioan Viorel
    Barkat, Fadila
    Istrate, Marcel
    Guerrero, Josep M.
    Culea, George
    Livinti, Petru
    Motas, Justina G.
    Neagu, Bogdan
    Andrioaia, Dragos
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 148
  • [4] A New Anti-islanding Method for Indirect Current Control of Grid Connected Inverter
    Park, Sungyoul
    Kwon, Minho
    Choi, Sewan
    2017 IEEE 3RD INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE AND ECCE ASIA (IFEEC 2017-ECCE ASIA), 2017, : 1230 - 1234
  • [5] Performance Analysis of GEFS and GEVS Anti-Islanding Methods for Three-Phase Grid Connected Photovoltaic Systems
    Lohmann, Andre
    Ribeiro Romaneli, Eduardo Felix
    Badin, Alceu Andre
    2018 13TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2018, : 806 - 810
  • [6] Comparison of Anti-islanding Protection in Single- and Three-Phase Solar Grid-Connected String Inverters
    Kumar K.J.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (01) : 225 - 235
  • [7] A novel active anti-islanding method for grid-connected photovoltaic inverter
    Jung, Youngseok
    Choi, Jaeho
    Yu, Gwonjong
    JOURNAL OF POWER ELECTRONICS, 2007, 7 (01) : 64 - 71
  • [8] Anti-Hebbian Control Algorithm for Three-Phase Inverter in Grid Connected Solar PV System
    Jain, Divya
    Kalla, Ujjwal Kumar
    2016 IEEE 7TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2016,
  • [9] A Minute Asymmetrical Current Injection Based Anti-islanding Method for Three-Phase Grid-Connected Photovoltaic Inverters
    Sun, Xiang-Dong
    Matsui, Mikihiko
    Yu, Byung-Gyu
    Koh, Kang-Hoon
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2011, 6 (01) : 65 - 72
  • [10] Grid-connected PV-APF system with anti-islanding protection
    Soto, Dionne
    Edrington, Chris
    Balathandayuthapani, Saritha
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2013, 23 (07): : 1049 - 1070