Precision in affinity capillary electrophoresis for drug-protein binding studies

被引:47
|
作者
El-Hady, Deia [2 ]
Kuehne, Sascha [1 ]
El-Maali, Nagwa [2 ]
Waetzig, Hermann [1 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Inst Pharmaceut Chem, D-38106 Braunschweig, Germany
[2] Assiut Univ, Fac Sci, Dept Chem, Assiut 71516, Egypt
关键词
ACE; Protein; Precision; Binding constant; HUMAN SERUM-ALBUMIN; HYDROXYPROPYL-CYCLODEXTRINS; ARRAY ELECTROPHORESIS; INCLUSION COMPLEXES; BETA-LACTOGLOBULIN; AQUEOUS-SOLUTION; CONSTANTS; CHROMATOGRAPHY; COLUMNS; ACID;
D O I
10.1016/j.jpba.2009.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to achieve excellent precision in the estimation of binding constants by affinity capillary electrophoresis (ACE), electroosmotic flow (EOF) stability is the key parameter, especially when using proteins in binding assays. Appropriate rinsing protocols are mandatory. In our study, the capillary was rinsed after each run with 0.1 mol/L sodium hydroxide for 2.0 min, with water for 2.0 min followed by running electrolyte (phosphate buffer at pH 7.4) for 3.0 min (pressure = 3000 mbar each). Tryptophan-human serum albumin, warfarin-bovine serum albumin and quercetin-beta-lactoglobulin were used as ACE models. Further improvements in precision have been obtained by avoiding a complete standstill of liquid within the capillary and flushing the capillary with buffer for 25 min after each 30 consecutive runs. The precision of measurements is further improved by the use of mobility ratios to report mobility changes (RSD% less than 0.5% in a long-term measurement, n = 300-600). Apart from the importance of a stable EOF, other ACE key parameters include protein concentration, drug plug length, applied voltage, and the choice of the regression method. In the present work, useful protocols and templates are provided in order to allow users a quick and efficient start with ACE methods. The comprehensive experimental part can serve as a checklist, which parameters need to be addressed for successfully applying ACE. Here, the suggested experimental design allows for the determination of binding constants within a couple of hours using standard instrumentation. This time could still be decreased by orders of magnitude using capillary arrays or miniaturized systems. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 241
页数:10
相关论文
共 50 条
  • [1] Rapid determination of protein binding constant by a pressure-mediated affinity capillary electrophoresis method
    Zhang, Bo
    Li, You X.
    Gao, He N.
    Bian, Juan
    Bao, James J.
    ELECTROPHORESIS, 2011, 32 (24) : 3589 - 3596
  • [2] Recent advances in affinity capillary electrophoresis for binding studies
    Albishri, Hassan M.
    El Deeb, Sami
    AlGarabli, Noura
    AlAstal, Raghda
    Alhazmi, Hassan A.
    Nachbar, Markus
    Abd El-Hady, Deia
    Waetzig, Hermann
    BIOANALYSIS, 2014, 6 (24) : 3369 - 3392
  • [3] High-Performance Affinity Chromatography: Applications in Drug-Protein Binding Studies and Personalized Medicine
    Li, Zhao
    Beeram, Sandya R.
    Bi, Cong
    Suresh, D.
    Zheng, Xiwei
    Hage, David S.
    ADVANCES IN PROTEIN CHEMISTRY AND STRUCTURAL BIOLOGY, VOL 102: PERSONALIZED MEDICINE, 2016, 102 : 1 - 39
  • [4] Evaluation of affinity microcolumns containing human serum albumin for rapid analysis of drug-protein binding
    Yoo, Michelle J.
    Schiel, John E.
    Hage, David S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (20): : 1707 - 1713
  • [5] Capillary affinity chromatography and affinity capillary electrophoresis of heparin binding proteins
    Wu, XJ
    Linhardt, RJ
    ELECTROPHORESIS, 1998, 19 (15) : 2650 - 2653
  • [6] Entrapment of alpha1-acid glycoprotein in high-performance affinity columns for drug-protein binding studies
    Bi, Cong
    Jackson, Abby
    Vargas-Badilla, John
    Li, Rong
    Rada, Giana
    Anguizola, Jeanethe
    Pfaunmiller, Erika
    Hage, David S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1021 : 188 - 196
  • [7] Experimental design and measurement uncertainty in ligand binding studies by affinity capillary electrophoresis
    Stein, Matthias
    Haselberg, Rob
    Mozafari-Torshizi, Mona
    Waetzig, Hermann
    ELECTROPHORESIS, 2019, 40 (07) : 1041 - 1054
  • [8] Binding studies of porphyrins to human serum albumin using affinity capillary electrophoresis
    Ding, YS
    Lin, BC
    Huie, CW
    ELECTROPHORESIS, 2001, 22 (11) : 2210 - 2216
  • [9] Investigation of competitive binding of ibuprofen and salicylic acid with serum albumin by affinity capillary electrophoresis
    Li, Zhu-Mei
    Wei, Chuan-Wan
    Zhang, Yintang
    Wang, Di-Shan
    Liu, You-Nian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21): : 1934 - 1938
  • [10] Detection of heterogeneous drug-protein binding by frontal analysis and high-performance affinity chromatography
    Tong, Zenghan
    Joseph, K. S.
    Hage, David S.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (49) : 8915 - 8924