Assessment of knee laxity using a robotic testing device: a comparison to the manual clinical knee examination

被引:11
作者
Branch, T. P. [1 ]
Stinton, S. K. [2 ]
Siebold, R. [3 ]
Freedberg, H. I. [4 ]
Jacobs, C. A. [5 ]
Hutton, W. C. [6 ]
机构
[1] Univ Orthopaed Clin, Decatur, GA USA
[2] ArthroMetrix LLC, Atlanta, GA 30324 USA
[3] ATOS Klin, Heidelberg, Germany
[4] Suburban Orthopaed, Bartlett, IL USA
[5] Lexington Clin, Lexington, KY USA
[6] Emory Univ, Sch Med, Dept Orthopaed, Atlanta, GA USA
关键词
Clinical knee examination; Knee injury; Knee laxity; Robotic knee testing; Ligament injury; Medial collateral ligament; Posterolateral corner; ANTERIOR CRUCIATE LIGAMENT; MEDIAL COLLATERAL LIGAMENT; BUNDLE ACL RECONSTRUCTION; IN-VIVO; TIBIAL ROTATION; ACCURACY; INJURIES; RELIABILITY; INSTABILITY; STABILITY;
D O I
10.1007/s00167-015-3935-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7A degrees larger valgus angle, 3A degrees greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/A degrees) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.
引用
收藏
页码:2460 / 2467
页数:8
相关论文
共 47 条
[1]   Measurements of knee rotation-reliability of an external device in vivo [J].
Almquist, Per O. ;
Ekdahl, Charlotte ;
Isberg, Per-Erik ;
Friden, Thomas .
BMC MUSCULOSKELETAL DISORDERS, 2011, 12
[2]   Biomechanics of the PCL and related structures: posterolateral, posteromedial and meniscofemoral ligaments [J].
Amis, AA ;
Bull, AMJ ;
Gupte, CM ;
Hijazi, I ;
Race, A ;
Robinson, JR .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (05) :271-281
[3]   Double-bundle ACL reconstruction demonstrated superior clinical stability to single-bundle ACL reconstruction: a matched-pairs analysis of instrumented tests of tibial anterior translation and internal rotation laxity [J].
Branch, T. P. ;
Siebold, R. ;
Freedberg, H. I. ;
Jacobs, C. A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (03) :432-440
[4]  
Branch TP, 2010, KNEE SURG SPORT TR A, V18, P1379, DOI 10.1007/s00167-009-1010-y
[5]   Robotic axial lower leg testing: repeatability and reproducibility [J].
Branch, Thomas ;
Stinton, Shaun ;
Sternberg, Maya ;
Hutton, William ;
Lavoie, Frederic ;
Guier, Christian ;
Neyret, Philippe .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (10) :2892-2899
[6]   Single-bundle ACL reconstruction with and without extra-articular reconstruction: evaluation with robotic lower leg rotation testing and patient satisfaction scores [J].
Branch, Thomas ;
Lavoie, Frederic ;
Guier, Christian ;
Branch, Eric ;
Lording, Timothy ;
Stinton, Shaun ;
Neyret, Philippe .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (10) :2882-2891
[7]  
Branch TP, 2011, 8 BIENN ISAKOS C RIO
[8]  
Chen F S, 2000, J Am Acad Orthop Surg, V8, P97
[9]  
Chouliaras V, 2009, J SPORT MED PHYS FIT, V49, P64
[10]   INSTRUMENTED MEASUREMENT OF ANTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
MALCOM, LL ;
LOSSE, G ;
STONE, ML ;
SACHS, R ;
BURKS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (05) :720-726