Low-dose interpolated average CT for attenuation correction in cardiac PET/CT

被引:6
作者
Wu, Tung-Hsin [4 ]
Zhang, Geoffrey [3 ]
Wang, Shyh-Jen [2 ,4 ]
Chen, Chih-Hao [2 ]
Yang, Bang-Hung [2 ,4 ]
Wu, Nien-Yun [2 ]
Huang, Tzung-Chi [1 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung, Taiwan
[2] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[3] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL USA
[4] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
关键词
Attenuation correction; Cine CT; Deformable image registration; PET; OPTICAL-FLOW; IMAGES;
D O I
10.1016/j.nima.2009.11.001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Because of the advantages in the use of high photon flux and thus the short scan times of CT imaging, the traditional Ge-68 scans for positron emission tomography (PET) image attenuation correction have been replaced by CT scans in the modern PET/CT technology. The combination of fast CT scan and slow PET scan often causes image misalignment between the PET and CT images due to respiration motion. Use of the average CT derived from cine CT images is reported to reduce such misalignment. However, the radiation dose to patients is higher with cine CT scans. This study introduces a method that uses breath-hold CT images and their interpolations to generate the average CT for PET image attenuation correction. Breath-hold CT sets are taken at end-inspiration and end-expiration. Deformable image registration is applied to generate a voxel-to-voxel motion matrix between the two CT sets. The motion is equally divided into 5 steps from inspiration to expiration and 5 steps from expiration to inspiration, generating a total of 8 phases of interpolated CT sets. An average CT image is generated from all the 10 phase CT images, including original inhale/exhale CT and 8 interpolated CT sets. Quantitative comparison shows that the reduction of image misalignment artifacts using the average CT from the interpolation technique for PET attenuation correction is at a similar level as that using cine average CT, while the dose to the patient from the CT scans is reduced significantly. The interpolated average CT method hence provides a low dose alternative to cine CT scans for PET attenuation correction. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 50 条
  • [41] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [42] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Jan Vontobel
    Riccardo Liga
    Mathias Possner
    Olivier F. Clerc
    Fran Mikulicic
    Patrick Veit-Haibach
    Edwin E. G. W. ter Voert
    Tobias A. Fuchs
    Julia Stehli
    Aju P. Pazhenkottil
    Dominik C. Benz
    Christoph Gräni
    Oliver Gaemperli
    Bernhard Herzog
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1574 - 1580
  • [43] Comparison of low-pitch and respiratory-averaged CT protocols for attenuation correction of cardiac PET studies
    Nye, Jonathon A.
    Hamill, James
    Tudorascu, Dana
    Carew, John
    Esteves, Fabio
    Votaw, John R.
    MEDICAL PHYSICS, 2009, 36 (05) : 1618 - 1623
  • [44] Brain PET Attenuation Correction without CT: An Investigation
    Dewan, Maneesh
    Zhan, Yiqiang
    Hermosillo, Gerardo
    Jian, Bing
    Zhou, Xiang Sean
    2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 110 - 113
  • [45] Sinogram-based attenuation correction in PET/CT
    Yang, Qingsong
    Lu, Yang
    Xi, Yan
    Cong, Wenxiang
    Kalra, Mannudeep
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (01) : 9 - 22
  • [46] Single-Phase CT Aligned to Gated PET for Respiratory Motion Correction in Cardiac PET/CT
    Wells, R. Glenn
    Ruddy, Terrence D.
    DeKemp, Rob A.
    DaSilva, Jean N.
    Beanlands, Rob S.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) : 1182 - 1190
  • [47] Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
    Kamel, EM
    Burger, C
    Buck, A
    von Schulthess, GK
    Goerres, GW
    EUROPEAN RADIOLOGY, 2003, 13 (04) : 724 - 728
  • [48] Ultra-low dose CT scanning for PET/CT
    Mostafapour, Samaneh
    Greuter, Marcel
    van Snick, Johannes H.
    Brouwers, Adrienne H.
    Dierckx, Rudi A. J. O.
    van Sluis, Joyce
    Lammertsma, Adriaan A.
    Tsoumpas, Charalampos
    MEDICAL PHYSICS, 2024, 51 (01) : 139 - 155
  • [49] Quantitative effects of contrast enhanced CT attenuation correction on PET SUV measurements
    Bunyaviroch, Tira
    Turkington, Timothy G.
    Wong, Terence Z.
    Wilson, John W.
    Colsher, James G.
    Coleman, R. Edward
    MOLECULAR IMAGING AND BIOLOGY, 2008, 10 (02) : 107 - 113
  • [50] A comparison of CT- and MR-based attenuation correction in neurological PET
    John C. Dickson
    Celia O’Meara
    Anna Barnes
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1176 - 1189