Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging

被引:46
作者
Blackburn, Caleb [1 ]
Rask, Hailee [1 ]
Awada, Abdallah [2 ]
机构
[1] Louisiana State Univ, Sch Dent, New Orleans, LA 70119 USA
[2] Louisiana State Univ, Sch Dent, Dept Prosthodont, 1100 Florida Ave,Box 222, New Orleans, LA 70119 USA
关键词
RESTORATIVE MATERIALS; LITHIUM DISILICATE; NETWORK MATERIAL; COMPOSITE RESIN; WEAR PROPERTIES; HUMAN ENAMEL; STRENGTH; ZIRCONIA; SYSTEMS; COLOR;
D O I
10.1016/j.prosdent.2017.08.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The development of polymer-based computer-aided design and computer-aided manufacturing (CAD-CAM) milling bocks and the limited availability of independent studies on these materials make it pertinent to evaluate changes in their mechanical properties after simulated aging to identify strengths and limitations. Purpose. The purpose of this in vitro study was to measure the effect of thermocycling on the flexural properties of ceramic, resin, and resin-ceramic CAD-CAM materials. Material and methods. Studied materials included Lava Ultimate Restorative (LVU; 3M ESPE), Enamic (ENA; VITA Zahnfabrik), Vitablocs Mark II (VM2; VITA Zahnfabrik), and Paradigm MZ100 (MZ1; 3M ESPE). Polished 4x1.2x14 mm bars (n=45 per material) were prepared from standard-size milling blocks. The 2 distilled water baths of the thermocycling apparatus were set to 5 degrees C and 55 degrees C, with a specimen immersion time of 15 seconds and transfer time of 4 seconds. Fifteen specimens from each material group were subjected to a 3-point flexural test at 3 different thermocycling intervals: 0 (control), 5000, and 10 000 cycles. The flexural test was performed over a 12-mm span with a crosshead speed of 0.5 mm/min. Data were subjected to multiple analyses of variance and the Tukey HSD post hoc tests (alpha=.05). Results. Mean flexural strength values for 0, 5000, and 10 000 cycles were 133, 130, and 128 MPa for VM2; 175, 139, and 134 MPa for LVU; 154, 144, and 138 MPa for MZ1; and 149, 136, and 132 MPa for ENA. Mean flexural modulus values were 51, 52, and 54 GPa for VM2; 14, 13, and 13 GPa for LVU; 16,15, and 15 GPa for MZ1; and 31, 30, and 31 GPa for ENA. Mean modulus of resilience values were 0.17,0.16, and 0.15 MPa for VM2; 10.1, 0.76, and 0.72 MPa for LVU; 0.77, 0.69, and 0.62 MPa for MZ1; and 0.42, 0.31, and 0.28 MPa for ENA. A significant difference was found among the materials in the mean change of flexural strength (P<.001) and modulus of resilience (P<.05) after thermocycling. No significant difference was found among the materials in the mean change of flexural modulus after thermocycling (P=.113). Conclusions. The mean flexural strength of resin-ceramics is significantly different from that of the feldspathic ceramic control at 0 and 5000 cycles, but not at 10 000 cycles. The mean modulus of resilience of resin-ceramics varies significantly after thermocycling, unlike the feldspathic ceramic control. Conversely, the mean flexural modulus of tested materials did not vary significantly after thermocycling.
引用
收藏
页码:954 / 958
页数:5
相关论文
共 30 条
[1]   Fatigue analysis of computer-aided design/computer-aided manufacturing resin-based composite vs. lithium disilicate glass-ceramic [J].
Ankyu, Shuhei ;
Nakamura, Keisuke ;
Harada, Akio ;
Hong, Guang ;
Kanno, Taro ;
Niwano, Yoshimi ;
Ortengren, Ulf ;
Egusa, Hiroshi .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2016, 124 (04) :387-395
[2]   Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns [J].
Attia, A ;
Abdelaziz, KM ;
Freitag, S ;
Kern, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) :117-123
[3]   Mechanical properties of resin-ceramic CAD/CAM restorative materials [J].
Awada, Abdallah ;
Nathanson, Dan .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04) :587-593
[4]   Micro-shear bond strength of different resin cements to ceramic/glass-polymer CAD-CAM block materials [J].
Cekic-Nagas, Isil ;
Ergun, Gulfem ;
Egilmez, Ferhan ;
Vallittu, Pekka Kalevi ;
Lassila, Lippo Veli Juhana .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (04) :265-273
[5]   Heat Transfer and Thermal Stress Analysis of a Mandibular Molar Tooth Restored by Different Indirect Restorations Using a Three-Dimensional Finite Element Method [J].
Koycu, Berrak Celik ;
Imirzalioglu, Pervin .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (05) :460-473
[6]   Machinability of CAD-CAM materials [J].
Chavali, Ramakiran ;
Nejat, Amir H. ;
Lawson, Nathaniel C. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) :194-199
[7]   Facially generated and cephalometric guided 3D digital design for complete mouth implant rehabilitation: A clinical report [J].
Coachman, Christian ;
Calamita, Marcelo Alexandre ;
Gray Coachman, Francis ;
Coachman, Robert Gray ;
Sesma, Newton .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05) :577-586
[8]   Wear Properties of a Novel Resin Composite Compared to Human Enamel and Other Restorative Materials [J].
D'Arcangelo, C. ;
Vanini, L. ;
Rondoni, G. D. ;
Pirani, M. ;
Vadini, M. ;
Gattone, M. ;
De Angelis, F. .
OPERATIVE DENTISTRY, 2014, 39 (06) :612-618
[9]   Wear properties of dental ceramics and porcelains compared with human enamel [J].
D'Arcangelo, Camillo ;
Vanini, Lorenzo ;
Rondoni, Giuseppe D. ;
De Angelis, Francesco .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (03) :350-355
[10]   Influence of the color of composite resin foundation and luting cement on the final color of lithium disilicate ceramic systems [J].
Dede, Dogu Omur ;
Sahin, Onur ;
Ozdemir, Oguz Suleyman ;
Yilmaz, Burak ;
Celik, Ersan ;
Koroglu, AySegul .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (01) :138-143