Real-time stereo 3D ultrasound

被引:1
作者
Noble, Joanna R. [1 ]
Fronheiser, Matthew P. [1 ]
Smith, Stephen W. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
stereo display; two-dimensional array; volumetric imaging;
D O I
10.1177/016173460602800404
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Real-time 3D ultrasound was developed at Duke University in 1991 and has since been used with a variety of transducers and shown effectiveness in clinical applications and in vivo animal imaging studies. Methods for displaying the 3D pyramid of data acquired by the system include selecting 2D image slices or integrating data into a volume rendered view. A third method, real-time stereo 3D imaging, is discussed here. The clinical commercial 3D system has been modified in our laboratory to display a real-time stereo image pair on the scanner display to be viewed through a stereoscope. This merges the pair into a single image, with a sensation of depth. Stereoscopic displays have previously been demonstrated to provide benefits, including improved depth judgments and increased perception of image quality in other applications. Previously-saved volumes of ultrasound data are shown in stereo 3D using the new system.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 50 条
  • [41] 3D H-scan ultrasound imaging system and method for acoustic scatterer size estimation: Preliminary studies using phantom materials
    Tai, Haowei
    Khairalseed, Mawia
    Hoyt, Kenneth
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1515 - 1518
  • [42] Feasibility of Multiplane-Transmit Beamforming for Real-Time Volumetric Cardiac Imaging: A Simulation Study
    Chen, Yinran
    Tong, Ling
    Ortega, Alejandra
    Luo, Jianwen
    D'hooge, Jan
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (04) : 648 - 659
  • [43] Feasibility study of real-time three-dimensional intracardiac echocardiography for guidance on interventional electrophysiology
    Smith, SW
    Light, ED
    Idriss, SF
    Wolf, PD
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (03): : 351 - 357
  • [44] Direct 3D Imaging through Spatial Coherence of Light
    Massaro, Gianlorenzo
    Barile, Barbara
    Scarcelli, Giuliano
    Pepe, Francesco V.
    Nicchia, Grazia Paola
    D'Angelo, Milena
    LASER & PHOTONICS REVIEWS, 2024, 18 (08)
  • [45] Dynamic dimension: System for simultaneous 3D and monoscopic viewing
    Redert, A
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XI, 2004, 5291 : 337 - 346
  • [46] A 3D lidar sensor for volumetric imaging in highly backscattering media
    Elkins, WP
    Ulich, BL
    Lawrence, JG
    Linton, HE
    Laser Radar Technology and Applications X, 2005, 5791 : 17 - 28
  • [47] Research progress on fast 3D fluorescence microscopic imaging (invited)
    Yan T.
    He Y.
    Wang X.
    Xu X.
    Xie H.
    Chen X.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (11):
  • [48] An innovative beamsplitter-based stereoscopic/3D display design
    Fergason, JL
    Robinson, SD
    McLaughlin, CW
    Brown, B
    Abileah, A
    Baker, TE
    Green, PJ
    STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XII, 2005, 5664 : 488 - 494
  • [49] Optimal pixel aspect ratio for enhanced 3D TV visualization
    Azari, Hossein
    Cheng, Irene
    Daniilidis, Kostas
    Basu, Anup
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2012, 116 (01) : 38 - 53
  • [50] Image coding and compression of confocal microscope volumetric 3D images
    Doukoglou, TD
    Strintzis, MG
    Pavlakos, A
    Hunter, IW
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1215 - 1217