Real-time stereo 3D ultrasound

被引:1
作者
Noble, Joanna R. [1 ]
Fronheiser, Matthew P. [1 ]
Smith, Stephen W. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
关键词
stereo display; two-dimensional array; volumetric imaging;
D O I
10.1177/016173460602800404
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Real-time 3D ultrasound was developed at Duke University in 1991 and has since been used with a variety of transducers and shown effectiveness in clinical applications and in vivo animal imaging studies. Methods for displaying the 3D pyramid of data acquired by the system include selecting 2D image slices or integrating data into a volume rendered view. A third method, real-time stereo 3D imaging, is discussed here. The clinical commercial 3D system has been modified in our laboratory to display a real-time stereo image pair on the scanner display to be viewed through a stereoscope. This merges the pair into a single image, with a sensation of depth. Stereoscopic displays have previously been demonstrated to provide benefits, including improved depth judgments and increased perception of image quality in other applications. Previously-saved volumes of ultrasound data are shown in stereo 3D using the new system.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 50 条
  • [1] Real time stereo 3D ultrasound
    Fronheiser, Matthew P.
    Noble, Joanna R.
    Light, Edward
    Smith, Stephen W.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2239 - 2242
  • [2] REAL-TIME STEREO RADIOGRAPHY
    BARRY, RC
    BARKER, MD
    KLYNN, LM
    MATERIALS EVALUATION, 1992, 50 (02) : 247 - 252
  • [3] Two dimensional arrays for real time 3D intravascular ultrasound
    Light, ED
    Smith, SW
    ULTRASONIC IMAGING, 2004, 26 (02) : 115 - 128
  • [4] Real-time 3D color flow Doppler for guidance of vibrating interventional devices
    Fronheiser, MP
    Wolf, PD
    Idriss, SF
    Nelson, RC
    Lee, W
    Smith, SW
    ULTRASONIC IMAGING, 2004, 26 (03) : 173 - 184
  • [5] Feasibility study: Real-time 3-D ultrasound imaging of the brain
    Smith, SW
    Chu, K
    Idriss, SF
    Ivancevich, NM
    Light, ED
    Wolf, PD
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (10) : 1365 - 1371
  • [6] Crossed-Array Transducer for Real-Time 3D Imaging
    Joyce, Andrew W.
    Lockwood, Geoffrey R.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2116 - 2120
  • [7] Advances in two dimensional arrays for real time 3D intravascular ultrasound
    Light, ED
    Smith, SW
    Angle, JF
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 790 - 793
  • [8] 3D ultrasound in robotic surgery: performance evaluation with stereo displays
    Novotny, Paul M.
    Jacobsen, Stephen K.
    Vasilyev, Nikolay V.
    Kettler, Daniel T.
    Salgo, Ivan S.
    Dupont, Pierre E.
    Del Nido, Pedro J.
    Howe, Robert D.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2006, 2 (03) : 279 - 285
  • [9] Guidance of cardiac pacemaker leads using real time 3D ultrasound: Feasibility studies
    Smith, SW
    Booi, RC
    Light, ED
    Merdes, CL
    Wolf, PD
    ULTRASONIC IMAGING, 2002, 24 (02) : 119 - 128
  • [10] Real-time stereo rendering of concentric mosaics with linear interpolation
    Wu, MS
    Sun, HH
    Shum, HY
    VISUAL COMMUNICATIONS AND IMAGE PROCESSING 2000, PTS 1-3, 2000, 4067 : 23 - 30