Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis

被引:26
作者
Lindquist, Chris M. [1 ]
Karlicki, Fern [2 ]
Lawrence, Patrick [2 ]
Strzelczyk, Jacek [2 ]
Pawlyshyn, Neal [3 ]
Kirkpatrick, Iain D. C. [2 ]
机构
[1] Univ Manitoba, Fac Med, Winnipeg, MB R3P 1X1, Canada
[2] St Boniface Gen Hosp, Dept Radiol, Winnipeg, MB R2H 2A6, Canada
[3] St Boniface Gen Hosp, Dept MRI, Winnipeg, MB R2H 2A6, Canada
关键词
balanced steady-state free precession; deep venous thrombosis; MR venography; trueFISP; ultrasound; ACUTE PULMONARY-EMBOLISM; VEIN-THROMBOSIS; ANGIOGRAPHY; TRUEFISP; SONOGRAPHY;
D O I
10.2214/AJR.09.3552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the sensitivity and specificity of balanced steady-state free precession MR venography in the diagnosis of lower extremity deep venous thrombosis. SUBJECTS AND METHODS. After undergoing lower extremity ultrasound because of suspicion of deep venous thrombosis, 64 patients were prospectively recruited to undergo balanced steady-state free precession MR venography with ultrasound as the reference standard. Ultrasound images were independently interpreted by two blinded ultrasound radiologists, and MR venograms were independently interpreted by two blinded MRI radiologists. The sensitivity, specificity, positive predictive value, and negative predictive value of MR venography were calculated for the diagnoses of all deep venous thrombosis, acute thrombi, and thrombosis of the popliteal, femoral, and common femoral veins individually. Proximal extent, thrombus age, ancillary findings, and interobserver agreement calculated with the Cohen kappa test were evaluated for ultrasound and MRI. The McNemar test was used to evaluate for statistical differences in diagnostic accuracy. RESULTS. MR venography had a sensitivity of 94.7%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 97.7% for the diagnosis of all thrombi. For acute thrombi, the MR venography and ultrasound results were completely concordant. MR venography depicted greater proximal extent in five of 18 cases in which thrombosis was found. The MR venographic findings agreed completely with the ultrasound findings in determination of thrombus age. For both ultrasound and MR venography, interobserver agreement was 100% on a per-patient basis. No statistical difference was identified in the diagnostic performance of the two techniques. CONCLUSION. Balanced steady-state free precession MR venography is highly accurate in the diagnosis of lower extremity deep venous thrombosis.
引用
收藏
页码:1357 / 1364
页数:8
相关论文
共 50 条
  • [41] Use of simulated annealing for the design of multiple repetition time balanced steady-state free precession imaging
    Lee, Kuan J.
    Lee, Hsu-Lei
    Hennig, Juergen
    Leupold, Jochen
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 220 - 226
  • [42] Current state of treatment for lower extremity acute deep venous thrombosis (a literature review)
    Nykonenko, A. O.
    Vailo, Yu M.
    Materukhin, A. M.
    ZAPOROZHYE MEDICAL JOURNAL, 2021, 23 (06) : 851 - 864
  • [43] Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging
    Staehle, F.
    Leupold, J.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1197 - 1202
  • [44] Nonenhanced Arterial Spin Labeled Carotid MR Angiography Using Three-Dimensional Radial Balanced Steady-State Free Precession Imaging
    Koktzoglou, Ioannis
    Meyer, Joel R.
    Ankenbrandt, William J.
    Giri, Shivraman
    Piccini, Davide
    Zenge, Michael O.
    Flanagan, Oisin
    Desai, Tina
    Gupta, NavYash
    Edelman, Robert R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) : 1150 - 1156
  • [45] Incidence and distribution of lower extremity deep venous thrombosis at indirect computed tomography venography in patients suspected of pulmonary embolism
    Nchimi, Alain
    Ghaye, Benoit
    Noukoua, Charlemagne T.
    Dondelinger, Robert F.
    THROMBOSIS AND HAEMOSTASIS, 2007, 97 (04) : 566 - 572
  • [46] Free-breathing half-radial dual-echo balanced steady-state free precession thoracic imaging with wobbling Archimedean spiral pole trajectories
    Bieri, Oliver
    Pusterla, Orso
    Bauman, Grzegorz
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (02): : 220 - 229
  • [47] The Utility of Screening for Asymptomatic Lower Extremity Deep Venous Thrombosis during Inflammatory Bowel Disease Flares: A Pilot Study
    Nguyen, Geoffrey C.
    Wu, Harry
    Gulamhusein, Aliya
    Rosenberg, Morgan
    Thanabalan, Reka
    Yeo, Erik L.
    Bernstein, Charles N.
    Steinhart, A. Hillary
    Margolis, Myles
    INFLAMMATORY BOWEL DISEASES, 2013, 19 (05) : 1053 - 1058
  • [48] Robust volume-targeted balanced steady-state free-precession coronary magnetic resonance angiography in a breathhold at 3.0 Tesla: a reproducibility study
    Soleimanifard, Sahar
    Stuber, Matthias
    Hays, Allison G.
    Weiss, Robert G.
    Schaer, Michael
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [49] Principles and applications of the balanced steady-state free precession sequence in small animal low-field MRI
    Mario Ricciardi
    Veterinary Research Communications, 2018, 42 : 65 - 86
  • [50] Principles and applications of the balanced steady-state free precession sequence in small animal low-field MRI
    Ricciardi, Mario
    VETERINARY RESEARCH COMMUNICATIONS, 2018, 42 (01) : 65 - 86