Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis

被引:26
|
作者
Lindquist, Chris M. [1 ]
Karlicki, Fern [2 ]
Lawrence, Patrick [2 ]
Strzelczyk, Jacek [2 ]
Pawlyshyn, Neal [3 ]
Kirkpatrick, Iain D. C. [2 ]
机构
[1] Univ Manitoba, Fac Med, Winnipeg, MB R3P 1X1, Canada
[2] St Boniface Gen Hosp, Dept Radiol, Winnipeg, MB R2H 2A6, Canada
[3] St Boniface Gen Hosp, Dept MRI, Winnipeg, MB R2H 2A6, Canada
关键词
balanced steady-state free precession; deep venous thrombosis; MR venography; trueFISP; ultrasound; ACUTE PULMONARY-EMBOLISM; VEIN-THROMBOSIS; ANGIOGRAPHY; TRUEFISP; SONOGRAPHY;
D O I
10.2214/AJR.09.3552
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the sensitivity and specificity of balanced steady-state free precession MR venography in the diagnosis of lower extremity deep venous thrombosis. SUBJECTS AND METHODS. After undergoing lower extremity ultrasound because of suspicion of deep venous thrombosis, 64 patients were prospectively recruited to undergo balanced steady-state free precession MR venography with ultrasound as the reference standard. Ultrasound images were independently interpreted by two blinded ultrasound radiologists, and MR venograms were independently interpreted by two blinded MRI radiologists. The sensitivity, specificity, positive predictive value, and negative predictive value of MR venography were calculated for the diagnoses of all deep venous thrombosis, acute thrombi, and thrombosis of the popliteal, femoral, and common femoral veins individually. Proximal extent, thrombus age, ancillary findings, and interobserver agreement calculated with the Cohen kappa test were evaluated for ultrasound and MRI. The McNemar test was used to evaluate for statistical differences in diagnostic accuracy. RESULTS. MR venography had a sensitivity of 94.7%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 97.7% for the diagnosis of all thrombi. For acute thrombi, the MR venography and ultrasound results were completely concordant. MR venography depicted greater proximal extent in five of 18 cases in which thrombosis was found. The MR venographic findings agreed completely with the ultrasound findings in determination of thrombus age. For both ultrasound and MR venography, interobserver agreement was 100% on a per-patient basis. No statistical difference was identified in the diagnostic performance of the two techniques. CONCLUSION. Balanced steady-state free precession MR venography is highly accurate in the diagnosis of lower extremity deep venous thrombosis.
引用
收藏
页码:1357 / 1364
页数:8
相关论文
共 50 条
  • [1] On the application of balanced steady-state free precession to MR microscopy
    Baer, Sebastien
    Oerther, Thomas
    Weigel, Matthias
    Mueller, Angelina
    Hucker, Patrick
    Korvink, Jan G.
    Ko, Cheng-Wen
    Wapler, Matthias C.
    Leupold, Jochen
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (04) : 437 - 447
  • [2] On the application of balanced steady-state free precession to MR microscopy
    Sébastien Bär
    Thomas Oerther
    Matthias Weigel
    Angelina Müller
    Patrick Hucker
    Jan G. Korvink
    Cheng-Wen Ko
    Matthias C. Wapler
    Jochen Leupold
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 437 - 447
  • [3] Assessment of deep venous thrombosis in the lower extremity in Behcet's syndrome: MR venography versus Doppler ultrasonography
    Tutar, Burcin
    Kantarci, Fatih
    Cakmak, Osman Serdal
    Yazici, Hasan
    Seyahi, Emire
    INTERNAL AND EMERGENCY MEDICINE, 2019, 14 (05) : 705 - 711
  • [4] COMPARISON OF SONOGRAPHY AND VENOGRAPHY IN THE DIAGNOSIS OF LOWER-EXTREMITY DEEP VENOUS THROMBOSIS
    MOSTBECK, GH
    KETTENBACH, J
    HENK, C
    RADIOLOGE, 1993, 33 (09): : 498 - 507
  • [5] MR angiography using steady-state free precession
    Foo, TKF
    Ho, VB
    Marcos, HB
    Hood, MN
    Choyke, PL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 699 - 706
  • [6] Abdominopelvic and Lower Extremity Deep Venous Thrombosis: Evaluation With Contrast-Enhanced MR Venography With a Blood-Pool Agent
    Huang, Steven Y.
    Kim, Charles Y.
    Miller, Michael J.
    Gupta, Rajan T.
    Lessne, Mark L.
    Horvath, Jeffrey J.
    Boll, Daniel T.
    Evans, Paul D.
    Befera, Nicholas T.
    Krishnan, Pranay
    Chan, Johanna L.
    Merkle, Elmar M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) : 208 - 214
  • [7] Pseudo Steady-State Free Precession for MR-Fingerprinting
    Asslaender, Jakob
    Glaser, Steffen J.
    Hennig, Juergen
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1151 - 1161
  • [8] High sensitivity MR acoustic radiation force imaging using transition band balanced steady-state free precession
    Zheng, Yuan
    Marx, Michael
    Miller, G. Wilson
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1532 - 1537
  • [9] Multiple Repetition Time Balanced Steady-State Free Precession Imaging
    Cukur, Tolga
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 193 - 204
  • [10] Unenhanced MR angiography of the renal arteries with balanced steady-state free precession Dixon method
    Stafford, Randall B.
    Sabati, Mohammad
    Haakstad, Michael J.
    Mahallati, Houman
    Frayne, Richard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 243 - 246