COMPARISON OF ULTRASOUND-GUIDED AND STANDARD LANDMARK TECHNIQUES FOR KNEE ARTHROCENTESIS

被引:48
|
作者
Wiler, Jennifer L. [1 ]
Costantino, Thomas G. [2 ]
Filippone, Lisa [1 ]
Satz, Wayne [2 ]
机构
[1] Drexel Univ, Coll Med, Dept Emergency Med, Philadelphia, PA 19104 USA
[2] Temple Univ, Dept Emergency Med, Philadelphia, PA 19122 USA
来源
JOURNAL OF EMERGENCY MEDICINE | 2010年 / 39卷 / 01期
关键词
knee; ultrasound; arthrocentesis; knee tap; joint aspiration; EMERGENCY ULTRASOUND; ULTRASONOGRAPHY;
D O I
10.1016/j.jemermed.2008.05.012
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Ultrasound is a useful adjunct to many Emergency Department (ED) procedures. Arthrocentesis is typically performed using a landmark technique but ultrasound may provide an opportunity to improve arthrocentesis performance. Objective: To assess the success of emergency physicians performing landmark (LM) vs. ultrasound (US)-guided knee arthrocentesis techniques. Methods: This was a prospective, randomized, controlled study of patients requiring knee arthrocentesis who presented to one urban university ED and two community EDs between June 2005 and February 2007. Results: There were 66 patients enrolled (39 US-guided, 27 LM). Among all users, there was no difference in arthrocentesis success (US 37/39 vs. LM 25/27); p = 1.0. Secondary Endpoints: 1) Patients reported less pain with ultrasound; US-guided 3.71 (95% confidence interval [CI] 2.61-4.80) cm vs. LM 5.19 (95% CI 3.94-6.45) cm; p = 0.02. 2) Providers felt the US-guided technique was easier to perform than LM; 1.67 units on 5-point scale (95% Cl 1.37-1.97) vs. 2.11 (95% CI 1.79-2.42) units; p = 0.02. 3) The total procedure time was shorter with the US-guided technique; 10.58 (95% CI 7.36-13.80) min vs. LM 13.37 (95% CI 9.83-16.92) min; p = 0.05. 4) There was no difference in the amount of fluid obtained between techniques; US-guided 45.33 (95% CI 35.45-55.21) mL vs. LM 34.7 (95% CI 26.09-43.32) mL; p = 0.17. Conclusion: US-guided knee arthrocentesis technique does not improve overall success of obtaining joint fluid aspirate vs. the standard LM and palpation technique. An US-guided approach does not result in more pain for the patient, takes no additional time to perform and, at least for novice physicians, leads to more fluid aspiration and greater novice provider confidence with the procedure. Further studies with more participants and standardization of anesthetic quantity are required to validate these findings. (C) 2010 Elsevier Inc.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 50 条
  • [41] Comparison of ultrasound-guided femoral
    Tabur, Zeynep Gumuskanat
    Yilmaz, Canan
    Karasu, Derya
    Baytar, Cagdas
    CUKUROVA MEDICAL JOURNAL, 2021, 46 (04): : 1433 - 1440
  • [42] Comparison of two methods of greater occipital nerve block in patients with chronic migraine: ultrasound-guided and landmark-based techniques
    Gursoy, Gizem
    Tuna, Hale Arkan
    BMC NEUROLOGY, 2024, 24 (01)
  • [43] Ultrasound-Guided Techniques for HIFU Monitoring
    Konofagou, E.
    MEDICAL PHYSICS, 2011, 38 (06) : 3801 - +
  • [44] A COMPARISON OF COMPUTERIZED TOMOGRAPHY-GUIDED STEREOTAXIC AND ULTRASOUND-GUIDED TECHNIQUES FOR BRAIN BIOPSY
    DILORENZO, N
    ESPOSITO, V
    LUNARDI, P
    DELFINI, R
    FORTUNA, A
    CANTORE, G
    JOURNAL OF NEUROSURGERY, 1991, 75 (05) : 763 - 765
  • [45] COMPARISON OF THE ARTERIAL AND CENTRAL VENOUS CANNULATION IN PALPATION AND ULTRASOUND-GUIDED TECHNIQUES
    Tirnava, A.
    Bakal, O.
    Yedekci, A. E.
    Inangil, G.
    Deniz, S.
    Ozkan, S.
    Sen, H.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 63 - 63
  • [46] Comparison of local anesthesia techniques during transrectal ultrasound-guided biopsies
    Stirling, BN
    Shockley, KF
    Carothers, GG
    Maatman, TJ
    UROLOGY, 2002, 60 (01) : 89 - 92
  • [47] Comparison of ultrasound-guided versus anatomical landmark-guided cannulation of the femoral vein at the optimum position in infants
    Eldabaa, Ahmed Ali
    Elgebaly, Ahmed Said
    Abd Elhafz, Ahmed Ali
    Bassun, Ahmed Sobhi
    ANNALS OF PEDIATRIC SURGERY, 2012, 8 (03): : 65 - 68
  • [48] Comparison of the establishment of a rabbit model of carpal tunnel syndrome under ultrasound-guided and landmark-guided methods
    Zhou, Qiao-Yin
    Li, Tian-Hua
    Zeng, Jing-Yuan
    Wu, Dan-Tong
    Li, Yun-Nan
    Chen, Qian
    Li, Shi-Liang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [49] A Randomized Comparison Between Ultrasound-Guided and Landmark-Based Superficial Cervical Plexus Block
    Tran, De Q. H.
    Dugani, Shubada
    Finlayson, Roderick J.
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2010, 35 (06) : 539 - 543
  • [50] Clinical and ultrasonographic evaluation of ultrasound-guided single puncture temporomandibular joint arthrocentesis
    Bilgir, Elif
    Yildirim, Derya
    Senturk, Mehmet Fatih
    Orhan, Hikmet
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2023, 41 (04): : 306 - 315