Exposure to ambient fine particulate matter and primary cardiac arrest among persons with and without clinically recognized heart disease

被引:71
作者
Sullivan, J
Ishikawa, N
Sheppard, L
Siscovick, D
Checkoway, H
Kaufman, J
机构
[1] Univ Washington, Sch Publ Hlth, Dept Environm Hlth, Seattle, WA 98105 USA
[2] Univ Washington, Sch Publ Hlth, Dept Biostat, Seattle, WA 98195 USA
[3] Univ Washington, Sch Publ Hlth, Dept Epidemiol, Seattle, WA 98195 USA
[4] Univ Washington, Sch Med, Dept Med, Seattle, WA 98195 USA
关键词
air pollutants; air pollution; heart arrest; heart diseases; environmental exposure;
D O I
10.1093/aje/kwg015
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The authors studied the association between incidence of primary cardiac arrest and daily measures of fine particulate matter (2.5 mum) using a case-crossover study of 1,206 Washington State out-of-hospital cardiac arrests (1985-1994) among persons with (n = 774) and without (n = 432) clinically recognized heart disease. The authors compared particulate matter levels on the day of the cardiac event and the 2 days preceding the event with levels from matched reference days. The estimated relative risk for a 13.8 mug/m(3) increase in fine particulate matter (nephelometry: 0.54 x 10(-1) km(-1) bsp) on the day prior to cardiac arrest was 0.94 (95% confidence interval: 0.88, 1.02). Pollutant levels measured on the same day as the event and on the 2 days preceding the event demonstrated similar results. No increased risk was found among all cases with preexisting cardiac disease (odds ratio = 0.97, 95% confidence interval: 0.89, 1.07); however, an unexpected association appeared between current smokers with preexisting heart disease and increased particulate matter levels 2 days prior to the event (odds ratio = 1.29, 95% confidence interval: 1.06, 1.55). This association was not present in the 0- or 1-day lag analyses or in persons with other diseases. There was no consistent association between increased levels of fine particulate matter and risk of primary cardiac arrest.
引用
收藏
页码:501 / 509
页数:9
相关论文
共 36 条
[11]  
Hayden, 2000, Curr Interv Cardiol Rep, V2, P218
[12]   Effects of ambient air pollution on daily mortality in a cohort of patients with congestive heart failure [J].
Kwon, HJ ;
Cho, SH ;
Nyberg, F ;
Pershagen, G .
EPIDEMIOLOGY, 2001, 12 (04) :S42-S42
[13]   A case-crossover analysis of particulate matter air pollution and out-of-hospital primary cardiac arrest [J].
Levy, D ;
Sheppard, L ;
Checkoway, H ;
Kaufman, J ;
Lumley, T ;
Koenig, J ;
Siscovick, D .
EPIDEMIOLOGY, 2001, 12 (02) :193-199
[14]   Referent selection in case-crossover analyses of acute health effects of air pollution [J].
Levy, D ;
Lumley, T ;
Sheppard, L ;
Kaufman, J ;
Checkoway, H .
EPIDEMIOLOGY, 2001, 12 (02) :186-192
[15]   Effects of nicotine nasal spray on atherogenic and thrombogenic factors during smoking cessation [J].
Lúdvíksdóttir, D ;
Blöndal, T ;
Franzon, M ;
Gudmundsson, TV ;
Säwe, U .
JOURNAL OF INTERNAL MEDICINE, 1999, 246 (01) :61-66
[16]  
Lumley T, 2000, ENVIRONMETRICS, V11, P689, DOI 10.1002/1099-095X(200011/12)11:6<689::AID-ENV439>3.0.CO
[17]  
2-N
[18]   THE CASE-CROSSOVER DESIGN - A METHOD FOR STUDYING TRANSIENT EFFECTS ON THE RISK OF ACUTE EVENTS [J].
MACLURE, M .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 133 (02) :144-153
[19]  
Mehta, 1997, J Cardiovasc Pharmacol Ther, V2, P291, DOI 10.1177/107424849700200407
[20]   MACROPHAGE INFILTRATION IN ACUTE CORONARY SYNDROMES - IMPLICATIONS FOR PLAQUE RUPTURE [J].
MORENO, PR ;
FALK, E ;
PALACIOS, IF ;
NEWELL, JB ;
FUSTER, V ;
FALLON, JT .
CIRCULATION, 1994, 90 (02) :775-778